Install Instructions

MOUNTING
Duct Mounting
Before beginning Duct Mounting:
I have conrmed local codes for proper draining practices for hot water
I have chosen an installation location that meets the requirements on page 10
Follow these steps to mount TrueSTEAM directly to the supply duct of the homeowner’s HVAC equipment.
STEP ONE: Select a Mounting Location
Choose a location that has access to a cold
water supply pipe.
Select a vertical or horizontal surface on the HVAC
supply duct, with adequate clearances, where
TrueSTEAM can be mounted.
Make sure there is a 120 VAC electrical outlet
rated for the TrueSTEAM model being installed.
Ensure the location is near a drain with a high-
temperature water rating. Consult local plumbing
codes for proper drainage. If no main oor drain
is available, see “Other Plumbing Options” on page 15.
STEP TWO: Connect the Duct Nozzle
Slide the foam gasket over the nozzle.
Make sure the o-ring gasket is properly seated
in the groove.
Insert the duct nozzle into TrueSTEAM. Twist clockwise
to ensure a tight seal.
M29598
M29599
TrueSTEAM Humidication System 69-2285—05
12
TrueSTEAM Required Minimum
Model: Circuit Capacity:
HM506 7 Amps
HM509 10 Amps
HM512 12 Amps
1
4
2
3
3
2
1