Install Instructions

PLUMBING
STEP THREE: Connect TrueSTEAM to the Cold Water Pipe
Connect one end of the remaining length of water
line to the backow preventer. Apply a modest pull
to ensure a tight t. See “Reverse Osmosis Filter” on
page 23 if using the Reverse Osmosis Filter.
Connect the other end of this line to the saddle valve
or T-tting and manual shutoff valve.
STEP FOUR: Connect to the Water Drain
Consult and follow local plumbing codes for drain
pipe size and maximum temperature requirement.
The ideal installation is directly to the main oor
drain using the rubber hose provided.
If direct oor drain access is not available, see
“Other Plumbing Options” on page 15.
Connect the 1/2-inch drain hose provided to the drain
tting on the bottom of the TrueSTEAM.
Use the hose clamp provided to secure the drain hose
to the barbed tting.
Route the drain hose to the oor drain. The hose must
have a continuous downward slope.
Direct the hose outlet into the oor drain. Secure
the hose to reduce the risk of hot water pooling
or splashing.
MCR32901
M29607
Before proceeding to Wiring:
I have conrmed minimum required circuit capacity
I have connected the water supply using cold water
I have installed the drain connection
CAUTION: Scalding Hazard.
During operation, hot water may exit drain and can cause burns from scalding.
Make sure the hose is securely connected to the drain.
TrueSTEAM Humidication System 69-2285—05 15
2
1
3
2
1
4