Install Instructions

APPENDICES
Setting up the RO Filter
See the instruction sheet packaged with the RO Filtration System for complete installation instructions.
1. Mount the base chassis to a surface capable
of holding up to 7 pounds between the home’s
cold water line and the TrueSTEAM location.
(Mounting hardware is provided.)
2. Connect the 1/4-inch white water line to the
home’s main cold water supply. Connect the
other end to the inlet port on the base chassis.
3. Connect the 1/4-inch white water line to the
outlet on the base chassis. Connect the other
end to the backow preventer. Connect another
water line between the backow preventer and
the TrueSTEAM supply tting.
4. Connect the yellow water line to the outlet port
on the clean water storage tank. Connect the
other end to the yellow inlet port on the RO
Filter System.
5. Connect the red tubing to the reject water port
on the base chassis, and to a suitable drain on
the other end.
IMPORTANT: Refer to and follow local codes
for proper drain installation. Refer to additional
drain requirements in the TrueSTEAM
installation guide when coupling the RO Filter
drain with the TrueSTEAM drain.
Standpipe
Condensate
Pump
Sump
Laundry
Tub
Drain points for reject water
Floor
Drain
Clean Water
Storage Tank
Cold Water Supply
M32912
1/4” White Tubing
Manual Shutoff Valve
Backflow
Preventer
White Tubing
Yellow
Tubing
Red Tubing
Drainflow Control
5
5
4
4
1
2
2
6
3
3
TrueSTEAM Humidication System 69-2285—05 25