Install Instructions

GETTING
STARTED
Set the Automatic Flush Cycle Timing
Use DIP 1 and DIP 2 to congure how often
TrueSTEAM will automatically ush the tank.
Timing for the automatic ush is based on hours of
active heating element time.
The home’s water hardness determines how often
automatic ushing should be performed.
The automatic ush timing can be changed any
time after installation by setting the DIP 1 and
DIP 2 positions, as shown at left. See “Automatic
Cleaning Cycle” on page 46 for a description of the
automatic ushing process.
65432
On
Off
1
654321
654321
654321
On
Off
On
Of
f
For water that is filtered through
the Honeywell RO Filter System.
(30 hour flush)
For hard water without
a softener or filter.
(8 hour flush)
For water that is put through
a softener before
entering TrueSTEAM.
(20 hour flush)
For soft water without
a softener or filter.
(12 hour flush)
On
Off
M29614
If water hardness is in range 1:
Honeywell recommends using the
polyphosphate lter (sold separately).
Proceed to “Water Supply and Drain
Connections” on page 13.
M29602
If water hardness is in range 2:
Honeywell recommends using the RO Filtration
system (sold separately).
Note: If the RO Filtration System is not used, set the homeowner’s
expectation that additional cleaning beyond once per season will
be necessary.
Proceed to “Water Supply and Drain
Connections” on page 13. See “Appendix F:
Reverse Osmosis Filter” on page 23 to install
the lter.
M29661
TrueSTEAM Humidication System 69-2285—05 3