Manual

TrueSTEAM Humidification System
3 69-2036EFS—07
M24852
M24772
PlumbIng
A
Insert 1/4-in. water line into filter. Apply modest pressure to ensure a tight fit.
10
B
Insert 1/4-in. water line into back-flow valve. Apply modest pressure for a tight fit.
Water line tapping options. See instructions provided with the option you choose.
M27428
C
D
1/4-in. water line
1/2-in.
drain tube
Enlarged view
T-fitting
To humidifier
Saddle valve (provided)
Piercing pin
Water supply line
To humidifier
Continuous
downslope
To water supply
Manual shutoff
valve (sold
separately)
Draining water may be
hot. Ensure drain outlet
not exposed. Ensure
drain or condensate
pump is rated for at
least 120°F water.
CAUTION
Hot water temperature above 120°F (49°C)
can cause burns from scalding.
Description Part Number
In-Line Water Filter (included)
(required for warranty)
50028044-001
Back-flow valve (included)
(required)
50030142-001
RemoTe mounT InsTallaTIon
C
Connect 1/2-in. drain tube. Secure drain tube to barbed fitting with hose clamp.
D
Shut off the water supply. Secure 1/4-in. copper or plastic water feed tube.
A
B
Check all water line connections to ensure no leaks once TrueSTEAM is operational.
1/4-in. copper
or plastic