User Guide

CLEANING AND
MAINTENANCE
How do I change the water lter?
Steam Humidication System 69-2286EF—05 19
Changing the reverse osmosis lter cartridges. If the reverse osmosis lter is used in your
installation, you will need to replace two lter cartridges once every humidication season. Notice that the
reverse osmosis lter option has more components than the in-line lter and includes a separate drain line.
This option provides better ltration and prevents harder water from owing into your Steam Humidier.
Remove lters #1, #2, and #3, in this order.
Reconnect lters in this order:
Empty water from the #3 lter and reconnect to the
RO System. (Do not replace.)
Connect a new #2 lter.
Connect a new #1 lter.
M29663
1
2