Portable Evaporative Air Cooler OWNER’S MANUAL Read and save these instructions before use Model: CL60PM Voltage rating: 220-240V`50Hz Power rating: 220W For product inquiries or support, visit www.honeywellaircoolers.com Or call Tel +44 (0) 1477 539 500 Fax +44 (0)1477 539 530 Email sales@scott-air-cooling.co.uk Made in P.R.C.
This page is intentionally left blank
INDEX Read all instructions carefully before setting up and operating the unit, and please keep this instruction manual for future reference. This manual is designed to provide you with important information needed to setup, operate, maintain and troubleshoot your cooler. Failure to follow these instructions may damage and/or impair its operation and void the warranty. SECTION 1. 2. 3. 4. 5. PAGE THANK YOU ...................................................................................................
THANK YOU THANK YOU! Congratulations on your purchase of this versatile Honeywell Evaporative Air Cooler. For optimum cooling performance from your unit, first fill it with water. Please read these instructions carefully.
USER TIPS COOL ~ EFFICIENT ~ NATURAL Evaporative air cooling is the natural way of cooling, similar to a breeze blowing across a lake.This breeze drops the temperature and has a relaxing cooling effect. The evaporative air cooler cools the air by means of the evaporation of water. When water evaporates into the air, the result is a mixture of air and water molecules. This chemical change requires heat which is taken from the water molecules, resulting in cooler air propelled from the unit.
USER TIPS The recommended maximum relative humidity level is 60% or less, which allows a noticeable temperature decrease. The temperature decrease will be greater in drier climates because higher evaporation occurs when the humidity is low. The evaporative air cooler should not be used in enclosed spaces. It must be kept level and there must be water in the water tank. The room should have doors and windows opened to allow free air flow.
SAFETY RULES READ AND SAVE THESE INSTRUCTIONS: When using electrical appliances, basic safety precautions should always be followed: • Your cooler runs on 220-240 Volt AC, 50 Hz current. Check the household voltage to ensure it matches the appliance's rate specification. • Before operating the product remove it from its packaging and check it is in good condition. • DO NOT operate any product with a damaged cord or plug. We recommend not to use an extension cord with this appliance.
SAFETY RULES • DO NOT attempt repair or adjust any electrical or mechanical functions of the cooler, as this may void the warranty. • DO NOT cover the air inlet or outlet on the appliance as this may cause motor damage. • DO NOT insert or allow objects to enter any ventilation or exhaust opening as this may damage the product and could cause an electrical shock or fire. • DO NOT operate with the Honeycomb media removed as this will overload and damage the motor.
PARTS DESCRIPTION 1 2 3 4 5 6 7 Water Inlet Handle Right Panel Lever for Horizontal Louvres Water Tank Castors Horizontal Louvres 8 Water Level Indicator 9 Control Panel 10 Left Panel 11 Continuous Water Inlet 12 Drain Plug 13 Manual Water Inlet 14 Back Panel CONTROL PANEL 7
USE & OPERATION INSTALLING HOSE ADAPTER AND FLOAT VALVE • Connect the garden hose Connector and turn on the water. • Verify water tight connections by visually examining both the float/hose connections. Hose Connector FILLING WATER Water can be filled into the air cooler by Continuous water supply Connect a garden hose to the continuous water supply inlet. Manual operation Water can be poured into the unit from the back. Water compartment Water can be put into the tank through the top opening.
USE & OPERATION CONTROL KNOBS SPEED / ON - OFF Connect to the power supply and turn the Speed knob. The fan will start. Change the speed from 1 for Low to 2 for Medium to 3 High. To switch OFF the unit turn the Speed know to "0". 0 3 2 1 SPEED COOL Turn the Cool knob to ON to start the cooling. It takes a few minutes to obtain the full effect from this mode. SWING Vertical Louvres Turn the SWING knob to 'ON'. The louvres will begin to move from right to left automatically.
CLEANING & MAINTENANCE WARNING • Before cleaning the unit, switch it to the ''OFF'' position and remove the plug from the power socket. • To clean the outside, use a damp cloth to remove dirt and dust. • Never use detergents, corrosive elements or any chemicals to clean this product. • When the product is not in use, store the unit in a dry place out of direct sunlight..
CLEANING & MAINTENANCE MAINTAING AND CHANGING THE HONEYCOMB • The appliance is supplied with Honeycomb cooling media. • Draining the water reservoir and refilling with fresh water at least once a week will greatly reduce mineral deposits in the pads and help to extend the life of Honeycomb cooling media. • Do not run the unit in COOL mode with stale water in the tank.
TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE SOLUTION No discharge of air Cord is not plugged in Make sure cord is plugged in and try to turn the unit on by pressing buttons on control panel or remote control. Power is not on Odour omission 12 Pump is not turned on Turn on COOL function Low / No water Refill water tank Damaged pump Replace pump.
TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE SOLUTION Unit is making noise Calcium build up in blower Contact service centre. Low or no water in the water tank when COOL is selected Pump will make noise if water level is near empty. Refill water tank. Service Centre: Scott Brothers Limited 1 Whiteside, Station Road, Holmes Chapel, Cheshire CW4 8AA, U.K. Tel +44 (0)1477 539 500 Fax +44 (0)1477 539 530 Email sales@scott-air-cooling.co.
TECHNICAL SPECIFICATIONS MODEL NO.
Warranty Warranty on Honeywell Cooler We undertake by this Warranty to rectify free of charge any fault due to poor workmanship or faulty materials occurring in this Honeywell evaporative cooler within 1 year from the date of purchase.
This page is intentionally left blank
Autorised Distributor: Scott Brothers Limited 1 Whiteside, Station Road Holmes Chapel Cheshire, CW4 8AA, U.K Tel +44 (0)1477 539 500 Fax +44 (0)1477 539 530 Email sales@scott-air-cooling.co.uk IM01-1009-000-000 December 2009 © 2009 AirTek International Corporation Limited The Honeywell Trademark is used under license from Honeywell International Inc. Honeywell International Inc. makes no representation or warranties with respect to this product. Manufactured by AirTek International Corporation Limited.