Centrale Controller Manuel de l’utilisateur 301C User Manual M-510324 7/10
Controller Unit 301C User Manual M-510324 7/10
Notices and Trademarks Copyright by Honeywell International Inc. July 2010 While this information is presented in good faith and believed to be accurate, Honeywell disclaims the implied warranties of merchantability for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customers. In no event is Honeywell liable to anyone for any indirect, special or consequential damages.
Symbol Definitions The following table lists the symbols used in this document to denote certain conditions: Symbol Definition ATTENTION: Identifies information that requires special consideration TIP: Identifies advice or hints for the user, often in terms of performing a task REFERENCE _ INTERNAL: Identifies an additional source of information within the bookset.
INTRODUCTION ............................................................11 Intended Use ......................................................................................... 11 Receiving and Unpacking ...................................................................... 11 Installation Instructions ...................................................................... 12 Basic Guidelines ....................................................................................
Event Menu .......................................................................................40 Action Menu ...........................................................................................42 Delays Menu .......................................................................................... 43 Latch Mode ............................................................................. 44 Conditions ..............................................................................................
Analog Value .......................................................................... 92 Binary Input ............................................................................ 92 Binary Output ......................................................................... 93 Binary Value ........................................................................... 93 Device .................................................................................... 93 Object Names .....................................
Introduction Introduction The 301C controllers act as nerve centers for gas detection networks, providing continuous monitoring for up to 96 connected units (plus 1 301ADI). Since the controllers are factory programmed to the owner’s specifications, installation is limited simply to mounting and connecting them. Once installed and connected, the controllers allow the user to monitor, adjust, or reconfigure an entire network of units.
Introduction Installation Instructions Installation Instructions Basic Guidelines Follow these instructions to the letter to ensure that the equipment will function properly. Failure to respect these guidelines will release Honeywell Analytics from any responsibility in the event of improper functioning: • • • • • 12 Locate all units in areas easily accessible for service.
Introduction Installation Instructions Surface Mount Installation It is recommended that controllers be installed 5 feet (1.5 m) above the floor, at approximate eye level. Ø .5cm ¼” 17.4 cm 6 13/32” 26.8 cm 10 9/16” 1.5m 5’ Mark the holes as shown: • • • • Height markers 6 13/32” apart Width markers 10 9/16” apart Pre-drill 1/4” mounting holes as needed Securely mount the 301C using the appropriate screws Wiring for the unit must be passed through the knock-outs provided at the bottom of the unit.
Introduction Wiring Details Wiring Details The diagram below provides the details required to connect the 301C with the wireless communication module (coordinator). This module allows the controller to communicate with and manage the 301W wireless gas detectors. Details concerning power supply, cables, capacities, etc., are provided in the Specifications section at the back of this manual. 9XOFDLQ ,QF 9$ &:35% 0DGH LQ &DQDGD .
Introduction Wiring Details The connectors, or ports, on the PCB allow various wiring to be connected to the controller. The wiring includes power, communication, BACNet and relays, each with an assigned position (and number) on the board: J22 Power Input: Connect the power supply to the controller (see Wiring Details for cabling diagrams) J23, J24 Communication inputs: Connect communication cables to channels 1 through 3.
Introduction Power Connections Power Connections The 301C requires a power range of 17-27 Vac, 50/60 Hz (8.64 VA), 18-36 Vdc, 350 mA @24 Vdc (8.4 VA). Polarization is not important in either AC or DC mode. The system must be grounded on the transformer and a dedicated circuit breaker must be used. Communication Connections Communication cables must be grounded using the shield terminal, using twisted and shielded pair Belden 2-24 AWG #9841 cable (or equivalent).
Introduction Relay Output Relay Output The relay output can withstand up to 5A at 30Vdc or 250Vac (resistive load only). Relays can be used to activate horns and strobes. Although each relay is programmed with a default setting (below), they can be configured using the controller programming menu. RELAY OUTPUTS N.O. COMM Normally open N.C. Normally closed If relays are set to Normally closed, the relay is powered up with the controller and the device linked to the relay is functioning.
Relay Output Jumper Use Instructions The jumpers on the controller PCB allow a variety of operations to be performed manually: EOL 1-4: Enables the user to add End-Of-Line jumpers that improve communication signals. Put the jumper in R position (as shown on wiring diagram) to activate the End-of-Line termination. (R provides a resistance termination and RC provides resistance and condensator termination.) SHDN: Enables the microcontroller to be reset or temporarily shut down.
Getting Started Relay Output Getting Started The controller units are customized to the purchaser’s specifications but they can be further programmed using the following menu options. Initial Startup Make sure that all wiring has been completed according to specifications in the wiring details before powering up the unit. When all is secure, remove the SHDN jumper to power-up the unit. It should only take a few seconds until the unit is fully operative.
Getting Started Programming Interface Programming Interface The front panel of the 301C provides a programming keypad (buttons) and LEDs. 301C front panel Keypad Keypad Functions Each unit has 7 keypad keys, or buttons: Arrows: ESC: Enter: Silence: 20 Used to move the cursor through the various programming fields (Up, Down, Left and Right), or to adjust the display contrast (press and hold the up or down arrow until desired contrast is reached and release).
Getting Started Programming Interface LED Definitions The controller is equipped with 7 LEDs that provide a status for each function related to that indicator: Alarm A: A blinking red light indicates that an event has been activated. A constant red light indicates that one or more transmitters has reached Alarm A or Alarm 1. Alarm B When the red indicator is on, one or more transmitters has reached Alarm B or Alarm 2. Alarm C When the red indicator is on, one or more transmitters has reached Alarm C.
System Programming Programming Interface System Programming The system’s Normal programming mode offers several menu options that are accessible from the main menu screen: Tx Info: Groups: Events: Acqui: Copy: Allows transmitter parameters to be programmed Allows groups of transmitters to be set up Allows events and event behavior to be programmed Allows the datalogging feature to be activated or deactivated Allows data or parameters to be copied from the (controller) configuration to parameters Config: A
System Programming Programming Interface The information screen also displays icons representing certain system functions. Here is a list of possible icons and their meaning: Icon Description BACNet: Indicates that there is a BACNet module present and that it is communicating with the controller. BACNet error: Indicates that a BACNet module is present but communication with the controller has failed (error) Debug: Indicates whether the controller is in debug mode (Single TX, Debug or Simulation modes).
System Programming Programming Interface Since the controller’s programming functions are password protected, it is necessary to access the login screen: • • • Press Enter to access the programming options. The password screen appears: Use the keypad Up or Down arrows to increase or decrease the value, one digit at a time, starting with the first digit When all the digits of the password are correct, press Enter to access the programming functions. PASSWORD ____ The first MENU options screen appears.
System Programming Tx Info Menu Tx Info Menu Tx Info is the menu option that is dedicated to transmitter information and contains several sub-menu options. The exact list of screens will vary depending on the transmitter type. A summary is presented below with details on the following pages Ident: COM: Allows the network component’s identification information to be viewed.
System Programming Tx Info Menu Ident Menu The Ident, or identification menu allows a component’s network ID to be consulted: 1. Tx Info -Ident- 001 NotVul CO2 (IR) The upper right corner of the screen shows the component’s address.
System Programming Tx Info Menu Product and Sensor Types This is a list of all the (preprogrammed) product types available from the Identification option in the Tx Info menu. 1. Tx Info -Ident- 121 301W CO2 (IR) The order of the products below is not necessarily the order in which they will appear in the controller Product Types Addresses 1-96 VA301D2 90DM3R VA301IRF IRT100 EC-F9 VA201T2 VA301T GsPnt RgRt3 VA301AP VASQN8X VA301EM VA301EMRP GsPnt2 S301RLC (Std.
System Programming Tx Info Menu The sensor type list applies to address ranges 1-96 and is not dependent on the type of product selected. Devices in the address range from 97-170 will display a BACNet object identifier, rather than a sensor type. *An additional Product Type, simply called “Group”, represents a group created in the Groups Menu in the controller.
System Programming Tx Info Menu COM Menu This screen displays the selected communication protocol for device addresses from 1 to 96. Each transmitter’s protocol is defined by the controller (see Network Auto-configuration section) . 1.
System Programming Tx Info Menu Scale Menus (1 and 2) These menus appear only for certain devices. Scale(1) allows the detection range, minimum and maximum, to be defined for the selected device. Whatever value is specified is the value that will appear at the device display (if applicable). The Minimum value is generally left at 0. Parameters for the XNX and XCD gas detectors can be viewed here but can be changed only at the transmitter. 1.
System Programming Tx Info Menu Detection Menu The detection menu (available only for devices with addresses between 1 and 96) displays the detection range (scale: 0-100.0) and the unit of measurement (unit: %) for the selected component. If a transmitter uses the Modbus protocol, the detection parameters are automatically defined during network configuration and are not editable. Vulbus protocols must be manually defined by the programmer. The detection scale is between 0 and the maximum value (0.
System Programming Tx Info Menu Display Menu This option allows a specific label or name to be assigned to the selected component (transmitters, relay modules, annunciators). Up to 20 characters, including spaces, can be used in the label (example: BOILER ROOM). The default Modbus transmitter labels are composed of the component (or transmitter) name, sensor type and address. Vulbus transmitter labels contain 20 blank characters (spaces). edit 301D2 32 1. Tx Info 001 -Display(20 char.
System Programming Tx Info Menu Alarm A, B and C Menus The screens for viewing alarm thresholds are combined in this manual. There will be either two or three levels, depending on transmitter type. If present, separate “MIN” and “MAX”levels permit manual control of the hysteresis of each alarm. Normally, the “MAX” level is set greater than “MIN.” However, alarms can be made to trigger on falling concentration (as with oxygen) by setting the “MAX” threshold smaller than the “MIN” threshold.
System Programming Tx Info Menu Servicing and Operating Menus These functions vary depending on the transmitter type. These displays show the total time the device has been in service and the amount of time remaining until the next required calibration or replacement.
System Programming Tx Info Menu Status Code These screens display transmission or node status and sensor status for the selected transmitter. This read-only information can assist service personnel in troubleshooting. The XNX and XCD gas detectors will report the warning or fault number (iFaultWarnNumber) in hexidecimal on the third line. These transmitters will also report the monitoring state (iMonitoringState) in the fourth line.
System Programming Tx Info Menu Change Tx Address Selecting Change Tx Address allows users to move a device from one TX address to another: • • • Use the arrows to scroll to Change Tx Address and press Enter to select In the next screen, scroll to the address number and press Enter to select Use the up or down arrows to increase or decrease the address value and press Enter to validate the new address.
System Programming Groups Menu Groups Menu Programming groups of transmitters allows several units to be combined which then enables actions (events) to be taken based on a series of units rather than each unit, individually. MENU 1. TxInfo 2. Groups 3. Events 4. Acqui 2. Groups [----] [----] [----] [----] [----] empty all groups 001 [----] [----] A group is a stack containing the addresses from each of the transmitters included in the group.
System Programming Groups Menu Creating Groups • • • • • Use the arrows to move the cursor to a group line and press Enter The field can be edited when the brackets stop blinking and the word “end” blinks Use the up or down arrows to scroll through the list of all units connected to the 301C, until the desired address is displayed . Press Enter again to validate the address. The address is added to the group and the bracket is shifted one position to the right.
System Programming Groups Menu Deleting Groups Use the empty all groups command to delete all groups previously programmed in the controller. Single groups can be deleted with a simple procedure: • • • Scroll to the first transmitter in the group list, Select the transmitter (its address blinks) and scroll to ( erases the entry and marks the end of the stack) Press enter and the group is emptied.
System Programming Event Menu Event Menu Though the controller has a default setting for Event configuration (as shown below), the Event menu is programmable.
System Programming Event Menu 3. Events -ActionTarget: Ctrl Relay: #01 3. Events -DelaysBefore: 99min After: 01min 1/3 = 3. Events Gr036 2.01% 001 001 001 AND 3. Events 001 -Coverage PeriodAll day All week 3. EVENEMENT -Status : disabledEnable event . 3.
System Programming Event Menu Action Menu Actions are comprised of two parameters: 3.
System Programming Event Menu Delays Menu This option allows Before and After settings that will delay the activation or deactivation of an action to be programmed. Before After Delays the action for the specified length of time. If the condition persists beyond this delay, the defined action is executed. The time to wait after an event has returned to normal before returning action output to normal state. The after delay also offers a Latch option, described below. 3.
System Programming Event Menu Latch Mode • • • • • The Latch function is executed on an Event state It is possible to select the Latch mode by changing the after delay to “ ” The Event stays active until the Silence keypad button is pressed The Silence keypad button has two functions: Silence the buzzer and unlatch the event. When the Silence keypad button is pressed, events in Latch mode are unlatched and reevaluated. If the Event condition persists, the Event remains active and returns to Latch mode.
Event Menu Conditions Conditions are the parameters that define what makes an Event true. Each condition is defined by four elements and can be combined with other conditions to provide greater flexibility. A condition, as in the example provided below, defines: IF at least 1/3 of group 36 detects concentrations greater than 2.01% of specified gas AND all of group 03 detects a concentration greater than 2.
System Programming Event Menu The top left portion contains the statistic quantifier (available only for Groups) that take only the specified part of the group into the equation.
System Programming Event Menu The bottom left portion contains the logic, or operator, quantifier that determines how conditions are calculated. Options available in this field are: Operator Symbol --= <= < >= > != max min Meaning No operator Equal to Equal to or smaller than Smaller than Equal to or larger than Larger than Not equal to When the maximum value is reached, an action is triggered.
System Programming Event Menu The bottom right portion contains the operand, which defines what device or group of devices on which the Event will be based. The list provides the following options: OFF ON: Fault: Used for status on binary inputs (ex.: used with 301ADI) Used for status on binary inputs (ex.: used with 301ADI) Bases trigger on maintenance alarm, communication failure or device failure Alrm A: If the chosen device or group has an Alarm A or Alarm 1, an event will be triggered.
System Programming Event Menu Status This screen displays the current event status and allows it to be either enabled or disabled, depending on the current status. Enable event:This is a “toggle” switch; press Enter to change the value from Enable to Disable and vice versa 3. EVENT -Status : disabledEnable event . 001 After going through all the steps and programming an event, this screen will display “Enable event”. Press Enter to activate all the parameters and enable the Event.
System Programming Acquisition Menu Acquisition Menu The Acquisition mode is only accessible when there is an SD card present (controllers with the Data Logging, or DLC function). It is used to enable or disable the logging of system Events or transmitter information. The information is logged (or recorded) on an SD card. Intervals or conditions must be defined before using this option. 4.
System Programming Acquisition Menu Starting and Stopping Tx Logging In the previous step, “Acquisition”, the frequency at which Tx logs would be recorded can be configured. To start the logging function: When “Start Tx logging” appears on the display, it indicates that the acquisition, or logging, mode is inactive. When “Stop Tx logging” appears, it indicates that Tx data is being logged. The log message is displayed on the screen according to the chosen mode and LED 1 will light up.
System Programming Acquisition Menu Starting and Stopping Event Logging The Acquisition menu offers an event logging option. Event Logging records controller transactions, events, Tx and alarm flags and relay status. When “Start Event logging” appears on the display, it indicates that the acquisition, or logging, mode is inactive. When “Stop Event logging” appears, it indicates that Event data is being logged. Press the Enter keypad button to stop or start Event logging.
System Programming Copy Menu Copy Menu The Copy menu allows programmed parameters to be copied and transferred. Data from the SD card can be transferred to a controller or from a controller to the SD card or copy parameters from one device to the next. The Copy option offers three screens: Configuration, Parameters and System Log. Configuration If the controller is equipped with an SD card, the configuration function allows data to be transferred either from the 301C to the SD card or the reverse.
System Programming Configuration Parameters The “parameters” function allows one transmitter’s configuration to be copied to another or one event’s parameters to be copied to another event. This allows several devices that share identical or similar parameters to be quickly configured. 5. Copy -parametersTxInfo to TxInfo Event to Event The options within this screen are: Tx Info to Tx Info copies transmitter parameters from one device to another. Event to Event copies parameters from Event to Event.
System Programming Configuration System Log Menu The controller will record log information to its internal memory. If the controller is equipped with an SD card, the system log function allows users to save system log information to the memory card in text format. 5. Copy -System LogSysLog to SDcard When this option is selected, a log of all the last actions performed on the controller is copied to the SDcard, with the filename slyymmdd.log.
System Programming Config Menu Config Menu The Config menu contains several main configuration screens and is used to program the controller display mode, adjust the date and time, select the display language, change the controller access password, modify the Slave Port configuration, set the Relay Configuration, and select the AP Broadcast mode. Each main screen offers further programming options, as shown. MENU 5. Copy 6. Config 7. Network 8. Tests 6.
Config Menu Selecting the first line of the first screen allows selection from three display modes: Manual scroll, 3-second scroll, 5-second scroll. If Manual scroll mode is chosen, the screen will only advance if you press on the arrow keypad buttons. If either 3 or 5 second scroll mode is chosen, the screens will automatically scroll display readings for all devices connected to the controller after 3 or 5 seconds. 6.
Config Menu The second main screen in the Config menu allows a new user password to be set and the slave port configuration to be modified. 6. Config Set User Password - 2967 Slave Port Cnfg The default password is 2967. Select Set User Password to change the password: • • • When the first digit blinks, change the value by using the up/down keypad arrows to increase or decrease the number Use the left/right keypad arrows to move from one digit to the next.
System Programming Config Menu Scroll through the main Config menu screens using the left (previous) or right (next) keypad arrows. The third main screen in the Config menu allows the relay configuration to be set, the AP broadcast mode and to select from four separate manufacturers for the given controller. 6.
System Programming Config Menu The fourth screen in the Config menu allows a definition of a day and a week to be programmed. 6. Config Day definition Week definition Day and Week definition allows hours (time frames) to be defined for either Daytime and Working Days respectively. Day definition -Daytimesta: 08:00 end: 17:00 Week definition -Working Dayssta: Monday end: Friday Note: Remember, the controller uses a 24 hour clock (0:00 to 23:59).
System Programming Network Menu Network Menu The Network menu allows network device information to be either scanned or reset. This menu offers four options, divided into two screens; the first screen contains three options: Reset Database: Network Scan: Reset and Scan: Resets all network device Tx information in the database. This only resets the Tx infomation for the network device. It does not affect programmed Groups or Events.
System Programming Network Menu The second Network screen offers the Statistics and Calibration options. 7. Network Statistics Calibration Selecting Statistics from the Network menu displays a screen containing the statistics for the selected device address.
System Programming Network Menu Remote Calibration The network menu also offers a Calibration option for use with devices that support network calibration. 7.
System Programming Network Menu 10. Press Enter to confirm or Esc to cancel. If confirmed, the controller calibrates the sensor’s Zero. This takes only a few moments and the display returns to the default calibration screen. Note: Never calibrate any unit’s Zero with ambient air. Always use Nitrogen (N2) at the calibration port to calibrate the Zero. 11.
System Programming Tests Menu Tests Menu The Tests menu allows a variety of tests to be performed on components and on the network communications. It also allows the system to be operated in four different modes which, in turn, provide different functionalities. MENU 5. Copy 6. Config 7. Network 8. Tests 8.
System Programming Tests Menu The Tests menu provides four main options, divided between two screens. Each of these options offers different capabilities. The first screen presents three options: 8. Tests Test sequence Start Sim Sequence Maximum load Test sequence: Start Sim Sequence: Maximum load: Enables each output to be activated and validates operation of each controller keypad buttons, display pixels, and various communication protocols.
System Programming Tests Menu Test Sequence When test sequence is selected from the main Tests menu, the controller will display the Test sequence screen. Test sequence Relays activated Any key to continue Esc to quit If Esc is pressed on the keypad, the main Tests menu screen will be displayed. However, to perform system tests, press any key to proceed to the first test screen.
System Programming Tests Menu The system then moves to the Display test. When the blank screen is displayed, it is testing for display pixels. Press any key to proceed to the next step. Test sequence Display test Any key to continue Esc to quit The final test that the system performs is a network communication test: Test sequence Test Network comm. 9600 bauds Channel 1 PASSED Once these tests have begun, do not interrupt or stop them.
System Programming Tests Menu Normal Mode This is the system’s normal (default) operation mode. When the system is in normal mode, some values can be changed without interrupting services. When a value has been changed in any of the menu fields, the change will take effect upon returning to the main menu screen. Single Tx Mode This mode allows transmitters to be analyzed one at a time. The controller polls only the selected device, which subsequently has its information updated.
System Programming Tests Menu Simulation Mode This mode deactivates network communication Information Updates. It can be combined with any of the three previous modes (example: using the Simulation mode when in Debug mode allows the user to test the entire system [groups, events, etc] without triggering any actions or using any additional material such as gases).
System Programming BACnet Menu BACnet Menu The BACNet menu offers several main menu screens to configure the BACNET IP connection, DHCP, server, time zone information and more.
System Programming Bacnet Menu The first of these screens allows the identification and address to be configured: 9. BACNet -DeviceBACnet ID : 1 Static IP address BACnet ID: (Building Automation and Control Networks) is the device ID number assigned to this particular controller on a network. Static IP address: This is an address that is used when DHCP is disabled. Changing BACNet values • • Use the keypad arrows to scroll down to select the desired line and press Enter to select it.
System Programming Bacnet Menu The next screen allows the device DHCP (Dynamic Host Configuration Protocol) to be enabled or disabled. 9. BACNet -DHCP : disabledEnable DHCP • Simply press Enter to change the field value. Consult the IT department for details concerning this option.
System Programming Bacnet Menu The next main BACNet screen allows modification of the SNTP (Simple Network Time Protocol) server IP address and configure the frequency at which the system will make SNTP server requests. Honeywell has made these options available to better adapt to the building’s network protocol, however Honeywell does not provide configuration or support for these options. 9.
Bacnet Menu The next main menu screen is the Date and Time screen. This screen allows the system’s time zone to be defined (if it differs from universal time) and whether daylight savings time is applicable. If the Time Zone field is selected, use the keypad arrows to scroll through the available times (from 0:00 to +13:00 and -12:00 to 0:00) 9. BACNet -Time ZoneTime Zone : 0:00 DST: OFF The Device Name screen allows a specific name to be assigned to the BACNet device. 9.
Bacnet Menu The Foreign Device Registration (FDR) allows users to enable the FDR and to set a specific Time To Live (in seconds). 9. BACNet -ForeignDevReg:disEnable FDR TTL: 43200 sec A Foreign Device is a BACNet device that has an IP subnet address different from those on the BACNet/IP network it seeks to join. The TTL (Time-To-Live) parameter is the registration duration supplied to the BBMD at the time of registration. Devices must re-register within this specified interval to remain connected.
System Programming Wireless Network Menu Wireless Network Menu The wireless menu allows wireless communication parameters to be set, wireless network diagnostics to be consulted, and the various aspects of the wireless nodes (sensors) to be accessed. Wireless Network 1. Parameters 2. Diagnostics 3. Nodes 4. New Node 5. Hibernate 6. Reset Network 7. Status Log NoLog 8. Consolidate route Parameters 1. 7B7177EFACE0049 2. WC Version 3. PAN ID 4. RF channel 5. Log Mode No Log 6. Association Ina 7. Nodes 0 8.
System Programming Wireless Network Menu Parameters Menu When Parameters is selected from the Wireless Network main menu options, all the coordinator parameters are displayed in order. The screen can only display three items at one time. Use the up or down arrows to scroll through the list of parameters. Parameters 1. 7B7177EFACE0049 2. WC Version 3. PAN ID 4. RF channel 5. Log Mode No Log 6. Association Ina 7. Nodes 0 8. Max nodes 0 9. Max hops 0 10. Power 0 11. AHFO 0 12. BO 0 13. SUO 0 14. LCO 18 15.
System Programming Wireless Network Menu Changing PAN ID or RF Channel When the PAN ID or the RF channel is changed, using the Parameters menu option within the Wireless Network menu, the system needs confirmation at more than one option, as described below: To change the PAN ID: • • • • • • • Select Parameters from the Wireless Network menu Scroll down (using the arrows) to hightlight option 3, PAN ID Press Enter to select Change the PAN ID values, as desired and press Enter The next screen requests eit
System Programming Wireless Network Menu The following table provides the list of parameters displayed for the coordinator (wireless communication module). Use the up or down keypad arrows to navigate the entire list. # 1. 2. 3. Title Value 7B177A7EFACE0049 WC Version A10 PAN ID FF07 4. 5. RF channel Log Mode 6. Association 11 No Log Ina 7. Nodes 0 8. Max nodes 0 9. Max hops 0 10. Power 0 11. AHFO 0 12. BO 0 13. SUO 0 14. LCO 18 15.
System Programming Wireless Network Menu # 16. Title MMO Value 0 17. BMO 0 18. KNSRO 0 19. FNSRO 0 20. Clone WC M-510324 7/10 Description Defines the bandwidth of the message retry measurement Defines the bandwidth of the missed beacons measurement Defines the frequency at which a node updates information from known neighbors Defines the frequency at which a node will scan for new neighbors Although accessible, this option is not available (will be used for future advanced use features).
System Programming Wireless Network Menu Diagnostics Menu The diagnostics menu allows both Weak Link and Lost Link reports to be consulted. These reports consist of the multiple-item node information list (as it appears in the Nodes menu). If there are no weak or lost links, the system will return the message “System Menu No Node Found”. If more than one node appears in this section, use the left or right keypad arrows to scroll through nodes. Diagnostics 1. Weak Link Report 2. Lost Link Report Nodes 1.
System Programming Wireless Network Menu Nodes Menu The Nodes menu displays a multiple-item node information list. Use the left and right keypad arrows to scroll between nodes and then use the up or down keypad arrows to scroll through the information list for each node. Nodes 1. ID 121 (79h) 2. 7B7177EFACE0049 3.
System Programming Wireless Network Menu The following table provides the list of data displayed for each node. Use the right or left keypad arrows to navigate the possible nodes, then use the up or down keypad arrows to navigate the entire list of data for the selected node. # 4. Title Link Quality Value 1 5. Log Mod Log 6. Net Addr 0009 7. SWU slot 1 8. # of Parents 1 9. DP Id 0 10. DP Net Addr 0 11. DP LQI 2 12. DP Retries (?) 13. DP BM 0 14. DP LC 256 15.
System Programming Wireless Network Menu # 18. Title AP1 Retries Value 128 19. AP1 BM (?) 20. AP1 LC 21. AP2 ID 27132 032 2 22. AP2 Net Addr 31756 23. AP2 LQI 198 24. AP2 Retries 190 25. AP2 BM 0 26. AP2 LC 56320 27. LSU 661 28. Status Alive 29. Freshness 2 30. 31. 32. 33. Version Hibernate Replace Remove A14 34. Consolidate Route 35.
System Programming Wireless Network Menu Options 1 through 29 are for information purposes only and cannot be modified. Options 16 through 21 are only displayed if the selected node has a second parent (a parent is any other node to which a node may connect to create a link to the controller). Option 22 through 27 are only displayed if the node has a third parent. Options 31 through 33 allow the Hibernate, Replace, or Remove nodes to be selected: Hibernate Places the node in hibernation (power down).
System Programming Wireless Network Menu New Node Menu The New Node menu allows users to add new nodes to the existing network, assigning a specific ID number to its MAC address. Wireless Network 4. New Node 5. Hibernate 6.
System Programming Wireless Network Menu Hibernate Menu The hibernate menu allows users to shut down the entire network of wireless nodes, to prevent any damage when maintenance is needed. Wireless Network 4. New Node 5. Hibernate 6. Reset Network Hibernate Enter to confirm Esc to cancel Reset Network Menu This function, which should only be used by authorized, fully qualified technicians, resets the wireless network parameters to zero, enabling nodes to look for a new controller in Association mode.
System Programming Wireless Network Menu Status Log Menu The Status Log file, named wyymmddq.log, that will be recorded on the SD card contains 27 columns of information (as in the sample above) that correspond to each of the first 27 fields in the Nodes Menu. Wireless Network 5. Hibernate 6. Reset Network 7. Status Log NoLog Status Log Log Status Log Enter to confirm Esc to cancel The resulting file can then be copied to a computer and consulted or printed, as needed.
System Programming Wireless Network Menu 90 301C User Manual Honeywell M-510324 7/10
BACnet/IP MODULE BACnet/IP MODULE (BIP option) Specifications Ethernet Port : 10/100-compatible with 10 Base-T interface, RJ-45 Visual Indicators : Green LED Yellow LED LINK ACT Network Configuration: See 301C BACnet menu section. BACnet/IP protocol UDP Port: 47808. This value is not modifiable using the 301C. The module has been developed as per ANSI/ASHRAE Standard 1352001 : BACnet®— A Data Communication Protocol for Building Automation and Control Networks.
BACnet/IP MODULE Analog Input The Analog Input object type defines a standardized object whose properties represent the externally visible characteristics of an analog input, such as a gas sensor. Supported properties for the Analog Input object type are : Object_Identifier, Object_Name, Object_Type, Status_Flags, Event_State, Reliability, Present_Value, Out_of_Service and Units.
BACnet/IP MODULE Binary Output The Binary Output object type defines a standardized object whose properties represent the externally visible characteristics of a binary output. A "binary output" is a physical device or hardware output that can be in only one of two distinct states, such as a relay or a switchable power output.
BACnet/IP MODULE Honeywell Products and BACnet Objects Object Names Object names are constructed in two parts, as follows: Part one: The device display label (product name) for the network in which the object resides. This value is editable only when using the 301C controller. Part two: Unique tag label among all the objects for the same device. Ex : “301D2 CO2 AD:14.CO2” where ‘301D2 CO2 AD:14’ is the device display label and ‘CO2’ is the unique tag label that identifies the object as a CO2 sensor.
BACnet/IP MODULE Object Table For Honeywell Network Devices Objects residing in Honeywell network devices Device GP2 301IRF 301EM 201T2/vulbus 90DM3R .GAZ .GAZ .GAZ .GAZ .GAZ .Amin .Amin .Amin .Amin .Alrm .Amax .Amax .Amax .Amax .Bmin .Bmin .Bmin .Bmin .Bmax .Bmax .Bmax .Bmax .Cmin .Cmin .Cmin .Cmin .Cmax .Cmax .Cmax .Cmax .rel1 .rel1 .rel1 (snsr1) .rel1 .rel2 .rel2 .rel2 (snsr1) .rel3 .rel3 (snsr1) .rel4 (snsr1) Objects .out1 (snsr1) M-510324 7/10 .
BACnet/IP MODULE Object Table For Honeywell Network Devices Objects residing in Honeywell network devices Device 301AP 301C 301R 301ADI 901T .rel1 .rel1 .rel1 .AI1 to .AI16 .GAZ .rel2 .rel2 .rel2 .BI1 to .BI12 .Amin .rel3 .rel3 .rel3 .Amax .buzz .rel4 .rel4 .Bmin .buzz .rel5 .Bmax .rel6 .Cmin .rel7 .Cmax Objects .
BACnet/IP MODULE Object Table For Honeywell Network Devices Objects residing in Honeywell network devices Device ECF9 S301RLC 301W 301RW Std.Device* .GAZ .GAZ .GAZ .rel1 .GAZ .Amin .Amin .Amin .rel2 .Amin .Amax .Amax .Amax .rel3 .Amax .Bmin .Bmin .Bmin .rel4 .Bmin .Bmax .Bmax .Bmax .rel5 .Bmax .Cmin .Cmin .Cmin .rel6 .Cmin** .Cmax .Cmax .Cmax .rel7 .Cmax** Objects .rel8 * Std.Device refers to the following products: S301M, 420MDBS and 90DM4 ** The values .
BACnet/IP MODULE Object Examples In the first example, we see the CO2 gas sensor input for a 301D2 Vulcain network device: Name : “301D2 CO2 AD:14.CO2” Value : 600 Units : PPM Object : 1.AI2* Description : Analog Input * 1 is the 301C unique device instance, AI is the object type and 2 is the unique instance of the object in this device. We identify this object as “Analog Input 2 of BACnet device 1”.
Protocol Implementation Conformance Statement Protocol Implementation Conformance Statement (Normative) BACnet Protocol Implementation Conformance Statement Date : August 1, 2005 Vendor Name : Honeywell Analytics Product Name : 301C -BIP Product Model Number: N/A Applications Software Version : 1.0 Firmware Revision : 1.0 BACnet Protocol Revision : 1.0 Product Description: The 301C -BIP has a module that uses BACnet communication.
Protocol Implementation Conformance Statement List all BACnet Interoperability Building Blocks Supported (Annex K) Data Sharing Data Sharing-ReadProperty-A (DS-RP-A) Data Sharing-ReadProperty-B (DS-RP-B) Data Sharing-ReadPropertyMultiple-A (DS-RPM-A) Data Sharing-ReadPropertyMultiple-B (DS-RPM-B) Data Sharing-ReadPropertyConditional-A (DS-RPC-A) Data Sharing-ReadPropertyConditional-B (DS-RPC-B) Data Sharing-WriteProperty-A (DS-WP-A) Data Sharing-WriteProperty-B (DS-WP-B) Data Sharing-Writ
Protocol Implementation Conformance Statement Network Management Network Management-Connection Establishment-A (NM-CE-A) Network Management-Connection Establishment-B (NM-CE-B) Network Management-Router Configuration-A (NM-RC-A) Network Management-Router Configuration-B (NM-RC-B) Alarm and Event Management Alarm and Event-Notification-A (AE-N-A) Alarm and Event-Notification Internal-B (AE-N-I-B) Alarm and Event-Notification External-A (AE-N-E-B) Alarm and Event-ACK-A (AE-ACK-A) Alarm and
Protocol Implementation Conformance Statement Device Management-ReinitializeDevice-A (DM-RD-A) Device Management-ReinitializeDevice-B (DM-RD-B) Device Management-Backup and Restore-A (DM-BR-A) Device Management-Backup and Restore-B (DM-BR-B) Device Management-List Manipulation-A (DM-LM-A) Device Management-List Manipulation-B (DM-LM-B) Device Management-Object Creation and Deletion-A (DM-OCD-A) Device Management-Object Creation and Deletion-B (DM-OCD-B) Device Management-Virtual Terminal-
Protocol Implementation Conformance Statement MS/TP slave (Clause 9), baud rate(s): Point-To-Point, EIA 232 (Clause 10), baud rate(s): Point-To-Point, modem, (Clause 10), baud rate(s): LonTalk, (Clause 11), medium: Other: Device Address Binding : Is static device binding supported? (This is currently necessary for twoway communication with MS/TP slaves and certain other devices.) Yes No Networking Options Router, BACnet / Modbus.
Specifications Specifications Power requirements 301C Operating temperature range Operating humidity range Operating altitude Network capacity Communication (length of lines) Wireless communication range: Wireless communication User interface Visual indicators Outputs Output rating Audible alarm Time delays Battery Enclosure Dimensions (HxWxD) Certifications M-510324 8/10 17-27 Vac, 50/60 Hz, 8.64 VA 18-36 Vdc, 350mA @ 24 Vdc (8.
Limited Warranty Limited Warranty Limited Warranty Honeywell Analytics, Inc. warrants to the original purchaser and/or ultimate customer ("Purchaser") of Vulcain products ("Product") that if any part thereof proves to be defective in material or workmanship within twelve (12) months, such defective part will be repaired or replaced, free of charge, at Honeywell Analytics' discretion if shipped prepaid to Honeywell Analytics at 4005 Matte Blvd.
Limited Warranty Exclusions A. If Gas sensors are part of the Product, the gas sensor is covered by a twelve (12) month limited warranty of the manufacturer. B. If gas sensors are covered by this limited warranty, the gas sensor is subject to inspection by Honeywell Analytics for extended exposure to excessive gas concentrations if a claim by the Purchaser is made under this limited warranty.
Limited Warranty Disclaimer of Unstated Warranties The warranty printed above is the only warranty applicable to this purchase. All other warranties, express or implied, including, but not limited to, the implied warranties of merchantability or fitness for a particular purpose are hereby disclaimed.
Centrale 301C Manuel de l’utilisateur M-510324 7/10
Avis et marques de commerce Tous droits réservés par Honeywell International Inc. Juillet 2010 Quoique cette information est présentée en bonne foi et est présumée exacte, Honeywell décline la garantie tacite de la qualité marchande pour un emploi particulier et offre aucune garantie exprès, è l’exception des conventions écrites avec et pour ses clients. Honeywell ne sera, sous aucune circonstance, responsable à qui que ce soit pour des dommages spéciaux ou indirectes.
Définitions des symboles Le tableau suivant contient la liste des symboles utilisés dans ce document pour indiquer certaine conditions : Symbole Définition ATTENTION: Identifie une information demandant une attention spéciale Truc: Identifie un conseil ou un truc pour l’utilisateur, souvent concernant une tâche RÉFÉRENCE- INTERNE Indique une source d’information supplémentaire à l’intérieur du document.
INTRODUCTION ............................................................11 Utilisation ........................................................................................... 11 Réception et vérification .................................................................... 11 Note:Instructions d’installation ........................................................... 12 Directives de base ................................................................................. 12 Installation murale ...........
Note:Menu groupes ...........................................................................38 Créer des groupes .................................................................................39 Supprimer des groupes ..........................................................................39 •Menu événement .............................................................................40 Action .....................................................................................................
Entrée analogique .................................................................. 96 Valeur analogique .................................................................. 96 Entrée binaire ......................................................................... 97 Sortie binaire .......................................................................... 97 Valeur binaire ......................................................................... 97 Dispositif ................................................
Introduction Utilisation Introduction La centrale 301C agit de centrale pour réseaux de détection de gaz, offrant une surveillance continue sur un maximum de 96 unités (avec un 301ADI) connectées. Puisque la centrale est configuré selon vos besoins, l’installation demande simplement le montage et la connexion. Aussitôt installée, la centrale vous permet de monitorer, d’ajuster ou de configurer un réseau complet d’unités.
Introduction Instructions d’installation Instructions d’installation Directives de base Suivre les instructions minutieusement pour assurer le bon fonctionnement de l’équippement.
Introduction Instructions d’installation Installation murale Nous recommandons d’installer les centrales à 1.5m (5 pi.) du sol. Mesurer les distances tel qu’indiqué : Ø .5cm ¼” 17.4 cm 6 13/32” 26.8 cm 10 9/16” 1.
Détails de connexion Instructions d’installation Détails de connexion Le dessin ci-dessous démontre la connexion pour la centrale. Les descriptions de connecteurs et de connexions se trouvent dans les pages suivantes. Ce module permet à la centrale de communiquer avec et de gérer les détecteurs de gaz sans-fil 301W. Les détails de câblage, alimentation, capacités, etc. se trouvent à la section Spécifications de ce guide.
Détails de connexion Instructions d’installation Les connecteurs, ou ports, de la carte (PCB) permettent d’effectuer la connexion du câblage à la centrale.
Détails de connexion Connexions d’alimentation Connexions d’alimentation La centrale 301C nécessite une plage d’alimentation de 17-27 Vca, 50/ 60 Hz (8.64 VA), 18-36 Vcc, 350 mA @24 Vcc (8.4 VA). La polarisation n’importe pas, que ce soit en mode CA ou CC. Le système doit être mis à la terre sur le transformateur et un circuit dédié doit être utilisé.
Détails de connexion Sortie relais Sortie relais La sortie relais supporte jusqu’à 5A à 30 Vcc ou 250 Vca (charge résistive seulement). Les relais peuvent activer les alarmes sonores et les lampes stroboscopiques. Consulter le dessin pour instructions de connexion. Chaque relais est configuré avec des valeurs par défaut, cependant, la configuration des relais peut être modifiée depuis le menu de programmation de la centrale.
Instructions pour cavaliers Instructions pour cavaliers Les divers cavaliers de la carte (PCB) permettent d’effectuer certaines opérations manuellement : EOL 1-4 : Permet l’ajout de cavaliers de fin de ligne pour améliorer les signaux de communication. Mettre le cavalier en position R pour activer la terminaison fin-de-ligne. (Position R offre une terminaison à résistance, tandis que RC offre une terminaison de condensateur.
Démarrage Enregistrement de données (sdcard) Démarrage Quoique la centrale est configurer selon vos besoins, la programmation peut toujours être modifiée par l’entremise de ses menus. Cette section du manuel vous guidera dans les options du menu de programmation. Premier démarrage Assurer que tout le câblage est terminé et effectué selon les spécifications et les détails de connexion avant de mettre la centrale sous tension.
Démarrage Interface de programmation Interface de programmation Le panneau avant du 301C comporte un clavier de boutons poussoirs puis des indicateurs DEL. Panneau 301C Fonctions du clavier La centrale comporte 7 touches de clavier, soit : Flèches : Utilisées pour naviguer les divers menus de programmation (haut, bas, gauche, droite), ou pour ajuster le contraste de l’affichage (appuyer et maintenir enfoncé une touche de flèche (haut = plus clair, bas=plus sombre).
Démarrage Definitions des DEL Definitions des DEL La centrale comporte 7 DEL indiquant le statut de chaque fonction : Alarm A : Le DEL rouge clignotant indique qu’un événement est activé. Le DEL rouge continu indique qu’un ou plusieurs transmetteurs ont atteint un niveau d’alarme programmé.
Programmation du système Operation du système Programmation du système Le mode de programmation Normal offre huit options de menu, tous accessibles du menu principale : Info Tx : Groupes : Evene : Acqui : Copy : Config : Network : Tests : BACNet: Wireless: Permet de configurer les paramètres des transmetteurs Permet de configurer des groupes de transmetteurs Permet de configurer des événement et les actions liées aux événements Permet d’activer ou de désactiver la fonction d’enregistrement de données Pe
Programmation du système Operation du système Lorsqu’en opération normale, le système affiche l’écran ci-dessous et déroule des écrans d’informations pour chaque dispositif connecté à la centrale: 301C Ad: 1 2006-05-17 Gr:0 Ver. 3.0 Ev:0 13:18:18 Si un ou plusieurs appareils connectés à la centrale sont en mode d’alarme, la centrale affichera seulement l’écran principal et les écrans pour les appareils en mode d’alarme.
Programmation du système Operation du système L’écran d’information affiche également des icônes représentant certaines fonctions. Voici la liste des icônes et leurs descriptions : Icône Description BACNet : Indique la présence d’un module BACNet en communication avec la centrale. Erreur BACNet : Indique la présence d’un module BACNet, mais que la communication avec la centrale est en faute (erreur) Débogage : Indique que la centrale est en mode débogage (modes de TX unique, Débogage ou Simulation).
Programmation du système Operation du système Puisque les fonctions de programmation de la centrale sont protégées par mot de passe, il est nécessaire d’accéder à l’écran de mot de passe : • • • • Appuyer sur Enter pour afficher l’écran « Mot de passe » Utiliser les flèches haut ou bas pour augmenter ou diminuer la valeur du premier chiffre Utiliser la flèche de droite pour passer au prochain chiffre Lorsque tous les chiffres sont exactes, appuyer sur Enter pour valider le mot de passe et accéder aux fonc
Programmation du système Menu INFO Tx Menu INFO Tx INFO Tx est l’option de menu dédiée aux informations de transmetteurs et contient plusieurs autres options qui peuvent varier selon l’adresse (ou le type) d’appareil. Certains appareils afficheront les options Tx INFO suivantes : Ident : COM : Permet de consulter ou modifier l’information d’identification de la composante de réseau.
Programmation du système Menu INFO Tx Menu Ident Le menu Ident, ou identification, permet de consulter ou de modifier l’identification de réseau de la composante sélectionnée : 1. InfoTx -Ident- 001 NotVul CO2 (IR) La partie supérieure droit de l’écran affiche l’adresse de réseau de la composante.
Programmation du système Menu INFO Tx Types de produit et types de sondes Voici une liste de tous les types de produits (preprogrammés) disponibles à partir de l’option -Ident- du menu INFO Tx. Types de produit Adresses 1-96 VA301D2 90DM3R VA301IRF IRT100 EC-F9 VA201T2 VA301T GsPnt RgRt3 VA301AP VASQN8X VA301EM VA301EMRP GsPnt2 S301RLC (Std.
Programmation du système Menu INFO Tx Voici une liste de tous les types de sondes (preprogrammés) disponibles à partir de l’option -Ident- du menu INFO Tx Types de sondes CH4 CO NH3 NO2 HCL R11 R12 R22 R134A R125 R123 F2 HF Comb CH4 CO CO H2 SO2 H2S ETO NO Cl2 SIH4 HCN O3 HBr BCl3 COCl2 B2H6 H2 AsH3 ClO2 PH3 CO Unknown IR sensor Comb (IR) R11 (IR) R12 (IR) R22 (IR) R134A (IR) R125 (IR) R123 (IR) Comb (IR) CO2 (IR) CO2 (IR) R245A (IR) FE227 (IR) R404A (IR) R507A (IR) R401A (IR) R13B1 (IR) R23 (IR) No sen
Programmation du système Menu INFO Tx COM Cet écran affiche le protocole de communication de la composante sélectionnée pour les adresses de 1 à 96. Le protocole de chaque transmetteur est défini par la centrale (voir la section Auto-configuration du réseau).. 1.
Programmation du système Menu INFO Tx Echelle (1 et 2) Ces menus apparaîssent uniquement pour certains dispositifs. Echelle (1) permet de modifier la plage de détection, minimum et maximum, pour l’appareil sélectionné. 1. INFO Tx -Echelle(1)Max 00250 Min 00000 121 Echelle (2) permet de configurer le facteur de division de la plage (entre 0 et 65535) et de modifier l’unité de mesure pour la plage sélectionnée. 1.
Programmation du système Menu INFO Tx Détection Le menu Détection (disponible uniquement pour les adresses de 1 à 96) affiche la plage de détection (plage: 0 à 0.00) ainsi que l’unité de mesure (unité : %) pour le transmetteur sélectionné. La plage de détection est entre 0 et la valeur maximale (0.00) et l’unité de mesure est soit ppm ou pourcent (%).
Programmation du système Menu INFO Tx Affichage Cette option permet de donner une étiquette ou un nom à la composante sélectionnée (transmetteur, relais et annonciateurs). L’étiquette peut contenir jusqu’à 20 caractères, incluant les espaces (ex. : CHAMBRE GICLEURS). Les étiquettes de transmetteurs Modbus sont assignés par défaut et sont composés du nom de la composante, le type de sonde et l’adresse. Les étiquettes de transmetteur Vulbus contiennent 20 espaces blancs. edition 301D2 M-510324 7/10 1.
Programmation du système Menu INFO Tx Alarme A, B et C Puisque les écrans d’affichage sont identiques pour chacun des alarmes, ils ont été regroupés aux fins de ce manuel. Cependant, chaque alarme doit être configuré séparément selon vos besoins. Cette option permet de configurer des niveaux d’alarme minimum et maximum pour les alarmes A, B et C. Ceci crée une plage de tolérance où aucune action n’est effectuée. Toutefois, si les concentrations de gaz dépassent le niveau maximum, un alarme est activé.
Programmation du système Menu INFO Tx Entretien et Exploitation des Menus Ces fonctions varient selon le type d'émetteur. Ces écrans montrent le temps total du dispositif a été mis en service et le temps restant jusqu'à la prochaine calibration nécessaires ou de remplacement. 1. INFO Tx 001 -Entretien4002h en fonction 15514h avant entr. 1. INFO Tx 121 -Temps d’OperationTemps de Vie: 00000 Depuis calib: 00730 M-510324 7/10 1.
Programmation du système Menu INFO Tx Code d’Etat Cet écran affiche l’état de la transmission (Tx) ou du noeud (seulement pour les appareils sans-fil) et l’état de la sonde pour l’adresse du dispositif sélectionné, en valeurs hexadécimales. Cet écran est aux fins d’informations seulement; les données affichées ne peuvent pas être modifiées. 1. INFO Tx 026 -Code d’EtatEtat Tx: 0000 Etat Monitor: 0001 L'étalage typique pour X ou Y 1.
Programmation du système Menu INFO Tx L’option Changer l’adresse permet de modifier l’adresse d’un dispotif : • • • Utiliser les flèches pour dérouler à Changer l’adresse pui appuyer sur Enter pour sélectionner À l’écran suivant, dérouler à l’adresse puis appuyer sur Enter pour sélectionner Utiliser les flèches haut ou bas pour augmenter ou diminuer la valeur puis appuyer sur Enter pour valider la nouvelle adresse.
Programmation du système Menu groupes Menu groupes La programmation de groupes de transmetteurs permet de regrouper des unités, ce qui permet d’agir (événements) en réponse à un groupe d’unités plutôt que sur chaque unité, individuellement. MENU 1. InfoTx 3. Evene 2. Groupes 4. Acqui 2. GROUPE 001 [----] [----] [----] [----] [----] [----] [----] vider les groupes Un groupe est un bloc contenant les adresses de chaque transmetteurs du groupe.
Programmation du système Menu groupes Créer des groupes • • • • • • • • Utiliser les flèches pour déplacer le curseur à la gauche du numéro de groupe Appuyer sur Enter puis changer le numéro Appuyer sur Enter pour valider (créer) Utiliser les flèches pour placer le curseur sur une ligne de groupe et appuyer sur Enter Le champ est en mode édition lorsque le clignote Uitliser les flèches haut et bas pour dérouler dans la liste d’unités connectées à la centrale jusqu’à l’obtention de l’adresse appropr
Programmation du système Menu événement Menu événement Quoique la centrale est expédiée avec des configurations d’événement par défaut (exemple ci-dessous), le menu Évenement offre la flexibilité de modifier les paramètres.
Programmation du système Menu événement 3. EVENEMENT -ActionCible: Ctrl Relais: #01 001 3. EVENEMENT -DelaisAvant: 99min Apres: 01min 001 3. EVENEMENT 1/3 Gr036 = 2.01% 001 ET 3. EVENEMENT -Periode couverteToute la journee Toute la semaine 001 3. EVENEMENT -Statut : desactiveActive evenement . 001 3. EVENEMENT -Base de donneeEffacer evenement Eff. Tous les even. 001 Les valeurs par défaut du système pour les actions à effectuer : • • • • • Relais No.
Programmation du système Menu événement Action Les Actions comprennent deux paramètres : 3.
Programmation du système Menu événement Délais Cette option permet de configurer les paramètres Avant et Après qui retardent l’activation ou la désactivation d’une action. Avant Après Retarde une action pour la durée de temps précisée. Si la condition persiste après le délai précisé, un alarme est activé et l’action précisée est effectuée. Retarde la désactivation d’une action; l’action continuera jusqu’à l’épuisement du temps de délais précisé et si l’événement n’est plus vrai.
Programmation du système Menu événement Délais mode latch La fonction Latch, disponible depuis le menu déroulant du délais Après, est exécuté sur un état d’événement. Essentiellement, c’est un circuit de verrouillage, c’est à dire qu’une intervention humaine est nécessaire pour déverrouiller l’action de l’événement. L’événement demeure actif jusqu’au moment de pression sur la touche Silence. Cette touche arrête l’alarme sonore et relâche l’événement.
Programmation du système Menu événement Conditions Les Conditions sont les paramètres de définition (de calculs) qui décident si un événement est vrai ou non. Chaque condition est définie par quatres éléments. Il est également possible de lier deux conditions pour obtenir une plus grande flexibilité. Une condition défini : Si au moins 1/3 du groupe 36 détecte des concentrations supérieures à 2.01% du gaz précisé ET tout les éléments du groupe 03 détectent une concentration supérieure à 2.
Programmation du système Menu événement La partie supérieur de gauche contient le quantificateur de statistique (disponible seulement pour les groupes). Cette option permet de choisir quelle partie du groupe à inclure dans l’équation.
Programmation du système Menu événement La partie inférieure à gauche de l’écran contient le quantificateur de logique, ou l’opérateur, qui détermine comment les conditions sont calculées. Les options disponibles dans ce champs sont : Symbole opérateur --= <= < >= > ! max./min Description Aucun opérateur Égal à Égal à ou inférieur à Plus petit que Égal à ou supérieur à Plus grand que Pas égal Lorsque la valeur maximum est atteinte, une action est déclenchée.
Programmation du système Menu événement La partie inférieure à droite de l’écran contient l’opérande, qui défini quel statut déclenchera un événement. Les options disponibles dans ce champ sont : OFF : ON : Faute : Alrm A: Alrm B: Alrm C: Utilisé pour le statut des entrées binaires (ex. : utilisé avec le 301ADI) Utilisé pour le statut des entrées binaires (ex.
Programmation du système Menu événement Statut Cet écran affiche le statut de l’évenement sélectionné et permet soit d’activer ou de désactiver, selon le statut actuel. Active evenement Appuyer sur Enter pour sélectionner Active evenement ou Desactive evenement 3. EVENEMENT -Statut : desactiveActive evenement . 001 Lorsque tous les détails d’un événement sont inscrits, le dernier écran de configuration affiche « Active evenement ». Appuyer sur Enter pour valider les paramètres et activer l’événement.
Programmation du système Menu acquisition Menu acquisition Le mode Acquisition est seulement disponible lorsque la centrale est munie d’une carte SD (option d’enregistrement de données). Cette fonction permet d’activer ou de désactiver l’enregistrement des événements du système ou les informations des transmetteurs. L’information est enregistrée sur une carte de mémoire « SD ». L’utilisateur doit configurer les intervales et les conditions d’enregistrement nécessaires à cette fonction. 4.
Programmation du système Menu acquisition Debuter et arreter log Tx L’étape précédente traitait la fréquence d’enregistrement de données. Maintenant, il faut débuter le processus : Lorsque « Debuter log Tx » est affiché, le mode acquisition (enregistrement) est inactif. Lorsque « Arreter log Tx » est affiché, les données sont en cours d’enregistrement. Un message d’enregistrement est affiché à l’écran et le DEL de la carte SD s’allume. Appuyer sur Enter pour Débuter ou Arrêter l’enregistrement.
Programmation du système Menu acquisition Débuter et arrêter log even. Le menu Acquisition offre l’option d’enregistrement d’événements. L’enregistrement d’événements enregistre les transactions de la centrale, les événements, les avertisseurs de Tx et d’alarmes et le statut de relais. Lorsque « Debuter log even. » est affiché, le mode acquisition (enregistrement) est inactif. Lorsque « Arreter log even. » est affiché, les données sonten cours d’enregistrement.
Programmation du système Menu copie Menu copie L’option Copie du menu Info TX permet de copier ou de transférer les paramètres programmés. Il est possible de transférer des données d’une carte SD de la centrale à un ordinateur et vice versa ou de copier des paramètres d’un transmetteur à un autre. L’option Copie offre trois écrans : Configuration, Paramètres et Journal Sys.
Programmation du système Menu copie Paramètres La fonction paramètres permet de copier la configuration d’un transmetteur à un autre ou de copier les paramètres d’un événement à un autre. Ceci permet une configuration plus rapide pour les unités partageant des paramètres identiques ou similaires. 5. Copie -parametresInfoTx vers InfoTx Evene. vers Evene. Les options de cette écran sont : InfoTx vers InfoTx copie les paramètres de transmetteur d’un unité à l’autre. Evene. vers Evene.
Programmation du système Menu copie Journal Sys La centrale enregistre les données du journal dans sa mémoire interne. Si la centrale est munie d’une carte mémoire, la fonction Journal Sys permet d’enregistrer les informations de journal du système en format texte sur la carte de mémoire flash (SD card). 5. Copie -Journal SysJournal vers SDcard Lorsque sélectionnée, cette option créé un registre de toutes les dernières actions de la centrale sur la carte de mémoire, dans un fichier nommé « slaammjj.
Programmation du système Menu config Menu config Le menu Config, avec quatres écrans principaux, permet de configurer le mode d’affichage de la centrale, d’ajuster la date et l’heure, de sélectionner le langage d’affichage , de changer le mot de passe d’accès à la centrale, de modifier le port esclave, régler la configuration des relais, sélectionner le mode d’émission AP. Chaque écran principale offre des options de programmation supplémentaires. MENU 5. Copie 6. Config 7. Reseau 8. Tests 6.
Programmation du système Menu config La sélection de la première ligne (du premier écran) offre le choix de trois modes d’affichage : Defilement manuel, Defilement 3 sec, Defilement 5 sec. Ces réglages contrôlent la présence et la fréquence d’affichage des données à l’écran de la centrale. Le mode de défilement manuel signifie que l’utilisateur doit appuyer sur les flèches pour visionner le statut de chaque unité connectée à la centrale.
Programmation du système Menu config Le deuxième écran principale de configuration permet de modifier le mot de passe et de modifier la configuration du port esclave. 6. Config Mot de passe usage - 2967 Cnfg port esclave Le mot de passe par défaut est 2967.
Programmation du système Menu config Pour changer l’adresse, le débit en bauds ou pour visionner le protocole de communication du port esclave : Déplacer le curseur à gauche de Cnfg port esclave et appuyer sur Enter.
Programmation du système Menu config Le troisième écran principale permet de régler la configuration des relais, le mode d’émission AP et de choisir parmi quatre fabricants pour la centrale. 6. Config Configurat. relais Emission AP: auto Honeywell La sélection Configurat. relais offre deux options supplémentaires pour la configuration des relais : La première option, Failsafe, permet d’activer (ou désactiver) tous les relais en appuyant sur la touche Enter.
Programmation du système Menu config Le quatrième écran de configuration permet de programmer une définition d’un jour et d’une semaine. 6. Config Definition jour Definition semaine Les définitions de jour ou de semaine permettent de définir les plages d’heures représentées par Jour et les plages de journées représentées par Semaine.
Programmation du système Menu Réseau Menu Réseau Le menu Reseau permet soit de réinitialiser ou de balayer les informations de dispositifs de réseau. Ce menu offre plusieurs options supplémentaires, en deux écrans. Le premier écran contient trois options : RAZ base de donnee : Réinitialise toutes les informations de dispositifs de réseau dans la base de données. Ceci réinitilise seulement les données de dispositif de réseau. Il n’y a aucun impacte sur les groupes ou les événements.
Programmation du système Menu Réseau La sélection de statistiques affichent les statistiques pour l’adresse précisée. Statistiques Valide 16 Erreurs 0 Sans rep 0 100% 0% 0% Valide: Indique le nombre de réponses valides pour les 16 dernières requêtes. Erreurs: Indique le nombre d’erreur de réponse pour les 16 dernières requêtes. Sans rep: Indique le nombre d’erreurs de temporisation (pas de réponse) pour les 16 dernières requêtes.
Programmation du système Menu Réseau Etalonnage Le menu Reseau offre également l’option Etalonnage permettant d’effectuer un étalonnage à distance pour les dispositifs qui supportent l’étalonnage en réseau. 7.
Programmation du système Menu Réseau 1. Déplacer le curseur à la gauche de l'adresse de l'unité sur la première ligne et appuyer sur Enter Etalon 001 : 301D2 Statut : Normal Etal Zero Etal plage 246 ppm 2. Dérouler la liste pour afficher l'adresse de l'unité désirée* puis appuyer sur Enter pour sélectionner. 3. La deuxième ligne affiche le statut de l'unité 4. Déplacer le curseur à la gauche de la fonction désirée, Etal Zero pour étalonner le zéro de l'unité, et appuyer sur Enter pour sélectionner. 5.
Programmation du système Menu Réseau 6. Appuyer sur Enter pour confirmer ou Esc pour annuler. Si confirmé, la centrale procède à l'étalonnage du zéro de l'unité. Le processus nécessite seulement quelques instant, puis l'écran affiche de nouveau l'écran d'étalonnage. Note: Ne jamais étalonner le zéro de l’unité avec de l’air ambiante seulement. Toujours utiliser de l’azote (N2) au port d’étalonnage pour étalonner le zéro. 7.
Programmation du système Menu Tests Menu Tests Le menu Tests permet d’effectuer une gamme de vérifications sur les composantes et sur les communications de réseau. Ce menu permet également d’opérer le système dans quatre modes différents, chacun offrant des fonctionalités particulières. MENU 5. Copie 6. Config 7. Reseau 8. Tests 8. Tests Sequence de test Debuter sequ. Sim.
Programmation du système Menu Tests Le menu Tests offre quatre options principales, disponibles sur deux écrans. Chacune de ces options offres des fonctionnalités supplémentaires. Le premier écran présente trois options : 8. Tests Sequence de test Debuter sequ. Sim. Charge maximum Sequence de test : Permet d’activer chaque sortie et de valider l’opération de chaque touche de clavier, des pixels d’affichage et les divers protocoles de communication de la centrale.
Programmation du système Menu Tests Sequence de test Lors de la sélection de cette option, la centrale affiche l’écran de Séquence de test. Appuyer sur ESC à n’importe quelle étape pour revenir à l’écran principale du menu Tests. Sequence de test Relais actives Appuyez une touche ESC pour quittter Appuyer sur n’importe quelle touche pour procéder aux tests du système.
Programmation du système Menu Tests Sequence de test Test affichage Pressez une touche ESC pour quitter Le dernier test est l’essais de communication de réseau : Sequence de test Test comm. reseau 9600 bauds Channel 1 SUCCES Assitôt ces essais commencés, il n’est pas possible de les interrompre ou de les arrêter. Le système essaye chacun des cinq bauds (vitesse de communication : 9600, 19200, 38400, 57600, 115200) et chacun des quatre canaux par baud.
Programmation du système Menu Tests Mode Normal Ceci est le mode d’opération normal (par défaut) du système. Lorsque le système est en mode normal, certaines valeurs peuvent être modifiées sans interruption de services. Toute modification est validée et effectuée lors du retour à l’écran principale. Mode Tx unique Ce mode permet d’effectuer l’analyse de transmetteurs, un à la fois. La centrale interroge seulement le transmetteur précisé, ce qui met à jour seulement les données de ce transmetteur.
Programmation du système Menu Tests Mode Simulation Ce mode désactive les mises à jour d’information de communication de réseau. Ce mode peut être employé, peu importe quel est le mode d’opération actuel du système (exemple: l’emploi du mode Silumlation simultanément avec le mode Débogage permet d’évaluer le système au complet [groupes, événements, etc.] sans déclencher des actions ou sans utilisation de matériel supplémentaire).
Programmation du système Menu BACNet Menu BACNet Le menu BACNet offre plusieurs écrans d’options permettant de configurer la connexion IP de BACNet, l’information du serveur et l’information du fuseau horaire. MENU 9. BACNet 10. Reseau sans-fil 9. BACNet - Appareil BACnet ID : 1 9. BACNet - DHCP : desactive Active DHCP 9. BACNet - Static IP Address 1 .254 192. 168. 9. BACNet - Static Netmask 0 255 .255 .255. 9. BACNet - Static Gateway 1 192 . 168 . 1 . 9.
Programmation du système Menu BACNet Le premier écran permet de configurer l’identification et l’adresse : 9. BACNet -AppareilBACnet ID : 1 Adresse statique IP BACnet ID : (Building Automation and Control Networks) est le numéro assigné à une centrale sur le réseau. 9. BACNet -Static IP Address 192.168. 1.
Programmation du système Menu BACNet Le deuxième écran permet d’activer ou de désactiver le protocole DHCP (Dynamic Host Configuration Protocol). 9. BACNet -DHCP : desactiveActive DHCP • Appuyer sur la touche Enter pour basculer le champs Activer ou Desactiver DHCP. Consulter votre service de TI pour de plus amples informations sur le DHCP.
Programmation du système Menu BACNet Le prochain écran principale BACNet permet de modifier l’adresse du serveur SNTP et de configurer la fréquence à laquelle le système effectuera des requêtes de serveur SNTP. Honeywell offre ces options pour que nos produits s’adaptent mieux à vos protocoles de réseau, cependant, nous ne’offrons ni la configuration, ni le soutien technique pour ces options. (SNTP=Simple Network Time Protocol, ) 9.
Programmation du système Menu BACNet Le prochain écran est l’écran Fuseau horaire. Cet écran permet de définir le fuseau horaire de votre système (S’il y a une différence entre celui de votre système et le temps universel) et si le système est dans une zone utilisant l’heure avancée. La sélection du champs fuseau permet d’utiliser les flèches pour dérouler dans une liste d’heures disponibles (de 0 :00 à +13 :00 et -12 :00 à 0 :00) 9.
Programmation du système Menu BACNet L’écran Foreign Device Registration (FDR) permet d’activer le FDR et de préciser une durée de vie (TTL, ou Time To Live) en secondes. 9. BACNet -ForeignDevReg:desActive: FDR TTL: 43200 sec Un « Foreign Device » est un dispositif BACNet dont l’adresse IP du sous-réseau est différente du réseau BACNet/IP auquel le dispositif veut se joindre.
Programmation du système Menu reseau sans-fil Menu reseau sans-fil Le réseau sans fil (disponible seulement dans le 301C-W, version 3 et plus du 301C) permet de configurer les paramètres de communication sans-fil, de consulter les diagnostics du réseau et de travailler avec les divers aspects des noeuds sans-fil (sondes). Reseau sans-fil 1. Parametres 2. Diagnostics 3. Noeuds 4. Nouveau noeud 5. Hiberner 6. RAZ reseau 7. Log Statut NoLog 8. Consolider accès Parametres 1. 7B7177EFACE0049 2. WC Version 3.
Programmation du système Menu reseau sans-fil Parametres Lors de la sélection de l’option Parametres depuis le menu Sans-fil, les paramètres sont affichés en ordre. Puisque l’écran peut seulement afficher 3 items à la fois, il est nécessaire de dérouler la liste de paramètres en utilisant les flèches haut et bas. Parametres 1. 7B7177EFACE0049 2. WC Version 3. PAN ID 4. Canal RF 5. Mode Log No Log 6. Association Ena 7. Noeuds 0 8. Max noeuds 0 9. Max sauts 0 10. Puissance 0 11. AHFO 0 12. BO 0 13.
Programmation du système Menu reseau sans-fil Modifier le PAN ID ou le Canal RF Lorsque le PAN ID ou le Canal RF est modifié depuis l’option Parametres du menu Reseau sans-fils, il est nécessaire de confirmer les modifications à plusieurs étapes.
Menu reseau sans-fil Le tableau ci-dessous contient la liste de paramètres affichés pour le coordonnateur (module de communication sans fil). Utiliser les flèches haut et bas pour dérouler la liste. # 1. 2. Titre Valeur 7B177A7EFACE0049 WC Version A10 3. PAN ID FF07 4. Canal RF 11 5. 6. Mode Log Association Log Ina 7. Noeuds 0 8. Max noeuds 0 9. Max sauts 0 10. Puissance 0 11. AHFO 0 12. BO 0 13. SUO 0 14.
Programmation du système Menu reseau sans-fil # 15. Titre LTO Valeur 0 16. MMO 0 17. BMO 0 18. KNSRO 0 19. FNSRO 0 20.
Programmation du système Menu reseau sans-fil Diagnostics Le menu diagnostics permet de consulter des rapports de liens faibles et de liens perdus. Lors de la sélection d’une de ces options, l’écran affiche une liste d’information pour le noeud (cette liste est identique à celle de l’option 3, Noeuds, du menu principal Sans-fil). S’il n’y a pas de liens faibles ou de liens perdus, l’écran affiche brièvement « Menu Systeme - Aucun noeud trouve » .
Programmation du système Menu reseau sans-fil Noeuds Le menu Noeuds contient toutes les informations sur un noeud. Utiliser les touches de clavier gauche et droite pour naviguer entre les noeud, puis les flèches haut et bas pour dérouler les informations de chaque noeud. Noeuds 1. ID : 121 (79h) 2. 7B7177EFACE0049 3.
Programmation du système Menu reseau sans-fil Le tableau suivant contient la liste des données affichées pour chaque noeud. Utiliser les flèches de gauche ou de droite pour naviguer de noeud en noeud, ensuite utiliser les flèches haut et bas pour dérouler la liste pour le noeud sélectionné. # 4. Titre Qualité lien Valeur 1 5. Mode d’op. Log 6. Adr reseau 0009 7. 1 8. Fenetre SWU # de parents 1 9. DP Id 0 10. DP Adr res 0 12. DP LQI 2 12. DP Retries (?) 13. DP BM 0 14.
Programmation du système Menu reseau sans-fil # 17. Titre AP1 LQI Valeur 16 18. AP1 Retries 128 19. AP1 BM (?) 20. AP1 LC 27132 032 21. AP2 ID 2 22. AP2 Adr res 31756 23. AP2 LQI 198 24. AP2 Retries 190 25. AP2 BM 0 26. AP2 LC 56320 27. LSU 661 28. 29. Statut Freshness Actif 2 30.
Programmation du système Menu reseau sans-fil # 31. 32. 33. Titre Hiberner Remplacer Enlever Valeur 34. Consolider accès 35. ’Failsafe’ N/A Description La sélection d’une de ces options ouvre un écran de confirmation. Lors de la confirmation, l’appareil est msi en sommeil profond (hors tension) pour pouvoir effectuer des réparations, pour effectuer des réparations, pour remplacer ou pour enlever le noeud.
Programmation du système Menu reseau sans-fil Les options 31 à 33 permettent de mettre le détecteur en mode d’hibernation (hors tension) pour effectuer des réparations, pour remplacer ou pour enlever le noeud. Hiberner Remplacer Enlever Met le noeud en hibernation (hors tension). Ce mode est utilisé aux fins d’entretien ou de remplacement de pile.
Programmation du système Menu reseau sans-fil Nouveau noeud Le menu Nouveau noeud permet d’ajouter un nouveau noeud dans le réseau et de préciser le numéro d’identificateur assigné à l’adresse MAC. Reseau sans-fil 4. Nouveau noeud 5. Hiberner 6.
Programmation du système Menu reseau sans-fil Menu Hiberner Le menu Hiberner permet de mettre (le réseau) en hibernation, c’est à dire de mettre les appareils sur le réseau hors tension. Ceci permet de faire de l’entretien sans risque d’endommager les appareils. Reseau sans-fi 4. Nouveau noeud 5. Hiberner 6.
Programmation du système Menu reseau sans-fil Menu Log Statut Ce menu permet de générer un fichier log qui sera enregistré sur la carte mémoire de la centrale (nommé waammjjq.log). Le registre contient 27 colonnes d’informations, correspondantes aux 27 premiers champs du menu noeuds. Reseau sans fil 5. Hiberner 6. RAZ reseau 7. Log Statut NoLog Log Statut Log Log Statut Enter pour confirmer Esc pour annuler Le fichier générer peut ensuite être consulté sur un ordinateur ou imprimé, selon les besoins.
Programmation du système Menu reseau sans-fil M-510324 7/10 Manuel de l’utilisateur 301C Honeywell 93
MODULE BACNET/IP (option -BIP) Spécifications Port Ethernet : Indicateurs : 10/100-compatible avec 10Base-T interface, RJ-45 DEL vert LINK DEL jaune ACT Configuration de réseau Voir section du menu VA301C BACnet. Protocole BACnet/IP Port UDP/IP: 47808, non modifiable depuis la centrale VA301C. Le module est développé selon la norme 135-2001 ANSI/ASHRAE : « BACnet®— A Data Communication Protocol for Building Automation and Control Networks ».
Objets BACNet Objets BACNet Les objets BACnet représentent toutes les informations disponibles par le sous-réseau du VA301C. Chacune des valeurs disponibles est représentée par un objet de type précis.
Objets BACNet Entrée binaire Le type d'objet Entrée binaire définit un objet normalisé dont les propriétés représentent des caractères externes visibles d'une entrée binaire. Une entrée binaire est un appareil ou un matériel physique qui peut être seulement en un de deux états possibles, tels les entrées numériques du VA301ADI.
Objets BACNet Dispositif Le type d'objet Dispositif définit un objet normalisé dont les propriétés représentent des caractères externes visibles d'un dispositif BACNet. Il y a seulement un objet Dispositif pour représenter le module BACNet.
Objets BACNet Labels repères d'objets Vulcain Labels repères .‘Gas label’ .Alrm .Amin / .Amax .Bmin / .Bmax .Cmin / .Cmax .relx .buzz .outx .AIx .BIx .RH .
Objets BACNet Objets pour les dispositifs de réseau Honeywell Objets pour les dispositifs de réseau Honeywell Dispositif GP2 301IRF 301EM 201T2/vulbus 90DM3R .GAZ .GAZ .GAZ .GAZ .GAZ .Amin .Amin .Amin .Amin .Alrm .Amax .Amax .Amax .Amax .Bmin .Bmin .Bmin .Bmin .Bmax .Bmax .Bmax .Bmax .Cmin .Cmin .Cmin .Cmin .Cmax .Cmax .Cmax .Cmax .rel1 .rel1 .rel1 (snsr1) .rel1 .rel2 .rel2 .rel2 (snsr1) .rel3 .rel3 (snsr1) .rel4 (snsr1) .out1 (snsr1) Objets .
Objets BACNet Objets pour les dispositifs de réseau Honeywell Objets pour les dispositifs de réseau Honeywell Dispositif 301AP 301C 301R 301ADI 901T .rel1 .rel1 .rel1 .AI1 to .AI16 .GAZ .rel2 .rel2 .rel2 .BI1 to .BI12 .Amin .rel3 .rel3 .rel3 .Amax .buzz .rel4 .rel4 .Bmin .buzz .rel5 .Bmax .rel6 .Cmin .rel7 .Cmax Objets .
Objets pour les dispositifs de réseau Honeywell Objets pour les dispositifs de réseau Honeywell Dispositif ECF9 S301RLC 301W 301RW Std.Device* .GAZ .GAZ .GAZ .rel1 .GAZ .Amin .Amin .Amin .rel2 .Amin .Amax .Amax .Amax .rel3 .Amax .Bmin .Bmin .Bmin .rel4 .Bmin .Bmax .Bmax .Bmax .rel5 .Bmax .Cmin .Cmin .Cmin .rel6 .Cmin** .Cmax .Cmax .Cmax .rel7 .Cmax** Objets .rel8 * Std.Device comprend les produits suivants : S301M, 420MDBS and 90DM4 ** Les valeurs .Cmin et .
Objets BACNet Exemples d'objet Exemple 1 Voici une représentation de l'entrée de sonde d'un dispositif de réseau VA301D2 de Vulcain. Name : “301D2 CO2 AD:14.CO2” Value : 600 Units : PPM Object : 1.AI2* Description : Analog Input * 1 est l'instance de dispositif unique du 301C, AI est le type d'objet et 2 est l'instance unique de l'objet dans ce dispositif. Cet objet est identifié « Entrée analogique 2 du dispositif BACNet 1 ».
Énoncé de conformité d'implémentation de protocole Énoncé de conformité d'implémentation de protocole (NORMATIF) Énoncé de conformité d'implémentation de protocole BACnet Date : août 1 2005 Nom du vendeur : Honeywell Analytics Nom du produit : 301C -BIP Numéro de modèle du produit : N/A Version de logiciel d'application : 1.0 Révision de micro logiciel : 1.0 Révision de protocole BACnet : 1.0 Description du produit : Le 301C -BIP comporte un module utilisant la communication BACnet.
Énoncé de conformité d'implémentation de protocole Liste de toutes les unités de structure d'interopérabilité BACnet supportées (Annexe K) : Partage de données Data Sharing-ReadProperty-A (DS-RP-A) Data Sharing-ReadProperty-B (DS-RP-B) Data Sharing-ReadPropertyMultiple-A (DS-RPM-A) Data Sharing-ReadPropertyMultiple-B (DS-RPM-B) Data Sharing-ReadPropertyConditional-A (DS-RPC-A) Data Sharing-ReadPropertyConditional-B (DS-RPC-B) Data Sharing-WriteProperty-A (DS-WP-A) Data Sharing-WritePropert
Énoncé de conformité d'implémentation de protocole Gestion de réseau Network Management-Connection Establishment-A (NM-CE-A) Network Management-Connection Establishment-B (NM-CE-B) Network Management-Router Configuration-A (NM-RC-A) Network Management-Router Configuration-B (NM-RC-B) Gestion d'alarme et d'événement Alarm and Event-Notification-A (AE-N-A) Alarm and Event-Notification Internal-B (AE-N-I-B) Alarm and Event-Notification External-A (AE-N-E-B) Alarm and Event-ACK-A (AE-ACK-A)
Énoncé de conformité d'implémentation de protocole Device Management-List Manipulation-A (DM-LM-A) Device Management-List Manipulation-B (DM-LM-B) Device Management-Object Creation and Deletion-A (DM-OCD-A) Device Management-Object Creation and Deletion-B (DM-OCD-B) Device Management-Virtual Terminal-A (DM-VT-A) Device Management-Virtual Terminal-B (DM-VT-B) Capacité de segmentation : Segmented requests supported window Size Segmented responses supported window Size : Take maximum Windows
Énoncé de conformité d'implémentation de protocole Options Couche liaison de données (Data Link Layer) : BACnet IP, (Annex J) BACnet IP, (Annex J), Foreign Device ISO 8802-3, Ethernet (Clause 7) ANSI/ATA 878.1, 2.5 Mb. ARCNET (Clause 8) ANSI/ATA 878.
Spécifications Spécifications Alimentation 301C 17-27 Vca, 50/60 Hz, 8.64 VA 18-36 Vcc, 350mA@24 Vcc, 8.
Garantie limitée Garantie limitée Garantie limitée Honeywell Analytics, Inc. garantie à l’Acheteur d’origine et/ou au client final (« Acheteur ») de produits Vulcain (« Produit ») que si une pièce quelconque du produit s’avère défectueuse , soit en matériel ou en main d’oeuvre, dans douze (12) mois, cette pièce sera réparée ou remplacer, sans frais, à la discrétion d’Honeywell Analytics si expédié, port payé, à Honeywell Analytics at 4005 Matte Blvd.
Garantie limitée Exclusions A. Si des capteurs de gaz font partie du Produit, le capteur est couvert par une garantie limitée de douze (12) mois du fabricant. B. Si les capteurs de gaz sont couverts par cette garantie limitée, le capteur sera assujeti à l’inspection par Honeywell Analytics pour l’exposition prolongée à des concentrations de gaz élevées si l’Acheteur fait une réclamation sous cette garantie limitée.
Garantie limitée Dénégation de responsabilité d’autres garanties La garantie ci-haut est la seule garantie applicable à cet achat. Toutes autres garanties, soit implicites ou exprès, incluant mais pas limité à, les garanties tacites de qualité marchande ou de l’aptitude à un emploi particulier sont dénéguées par le présent document.