Datasheet

31
sensing.honeywell.com
Table 13. TruStability
®
Board Mount Pressure Sensors Portfolio Overview
Characteristic
Series
HSC SSC TSC NSC
Package:
DIP (Dual In-Line Pin)
SMT (Surface Mount Technology)
SIP (Single In-Line Pin)
Option:
dry gases only, no diagnostics (all pressure ranges)
dry gases only, diagnostics on (all pressure ranges)
liquid media on port 1, no diagnostics (±60 mbar to ±10 bar | ±6 kPa to ±1 MPa | ±1 psi to ±150 psi
)
liquid media on port 1, diagnostics on (±60 mbar to ±10 bar | ±6 kPa to ±1 MPa | ±1 psi to ±150 psi)
Pressure range:
Absolute:
1 bar to 10 bar | 100 kPa to 1 MPa | 15 psi to 150 psi
Differential:
±60 mbar to ±10 bar | ±6 kPa to ±1 MPa | ±1 psi to ±150 psi
±1.6 mbar to ±40 mbar | ±160 Pa to ±4 kPa | ±0.5 inH
2
O to ±30 inH
2
O
Gage:
60 mbar to 10 bar | 6 kPa to 1 MPa | 1 psi to 150 psi
2.5 mbar to 40 mbar | 250 Pa to 4 kPa | 1 inH
2
O to 30 inH
2
O
Temperature compensated
Amplified
Output type:
analog
digital (SPI and I
2
C)
Transfer function:
10% to 90% of Vsupply (analog), 2
14
counts (digital)
5% to 95% of Vsupply (analog), 2
14
counts (digital)
5% to 85% of Vsupply (analog), 2
14
counts (digital)
4% to 94% of Vsupply (analog), 2
14
counts (digital)
Supply voltage:
3.3 Vdc
5.0 Vdc
1.5 Vdc to 12.0 Vdc (for pressure ranges >60 mbar | 6 kPa | 1 psi)
2.7 Vdc to 6.5 Vdc (for pressure ranges <40 mbar | 4 kPa | 20 inH
2
O)
Accuracy <0.25 %FSS BFSL
Compensated temperature range:
-20 °C to 85 °C [-4 °F to 185 °F]
0 °C to 85 °C [32 °F to 185 °F]
0 °C to 50 °C [32 °F to 122 °F]
Operating temperature range:
-20 °C to 85 °C [-4 °F to 185 °F]
-40 °C to 85 °C [-40 °F to 185 °F]
Total Error Band:
down to ±1% Full Scale Span max.
down to ±2% Full Scale Span max.
TruStability
®
Board Mount Pressure Sensors Portfolio Overview