Datasheet

9
sensing.honeywell.com
Table 5. Analog Operating Specifications
Characteristic
Min. Typ. Max. Unit
Supply voltage (V
supply
):
1, 2, 3
pressure ranges >60 mbar | 6 kPa | 1 psi:
3.3 Vdc
5.0 Vdc
pressure ranges <40 mbar | 4 kPa | 20 inH
2
O:
3.3 Vdc
5.0 Vdc
3.0
4.75
3.27
4.95
3.3
5.0
3.3
5.0
3.6
5.25
3.33
5.05
Vdc
Supply current:
3.3 Vdc
5.0 Vdc
2.1
2.7
2.8
3.5
mA
Operating temperature range
4
-20 [-4] 85 [185] °C [°F]
Compensated temperature range
5
0 [-32] 50 [122] °C [°F]
Startup time (power up to data ready) 5 ms
Response time 1 ms
Clipping limit:
upper
lower
2.5
97. 5
%Vsupply
Accuracy
6
±0.25
%FSS BFSL
8
Output resolution 0.03 %FSS
Orientation sensitivity (±1 g):
7, 9
pressure ranges <40 mbar | 4 kPa | 20 inH
2
O
pressure ranges <2.5 mbar | 250 Pa | 1 inH
2
O
±0.1
±0.2
%FSS
8
1
Sensors are either 3.3 Vdc or 5.0 Vdc based on the catalog listing selected.
2
Ratiometricity of the sensor (the ability of the device output to scale to the supply voltage) is achieved within the specified operating voltage.
3
The sensor is not reverse polarity protected. Incorrect application of supply voltage or ground to the wrong pin may cause electrical failure.
4
Operating temperature range: The temperature range over which the sensor will produce an output proportional to pressure.
5
Compensated temperature range: The temperature range over which the sensor will produce an output proportional to pressure within the specified
performance limits.
6
Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at 25 °C [77 °F]. Includes
all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability.
7
Orientation sensitivity: The maximum change in offset of the sensor due to a change in position or orientation relative to Earth’s gravitational field.
8
Full Scale Span (FSS): The algebraic difference between the output signal measured at the maximum (Pmax.) and minimum (Pmin.) limits of the pressure range.
(See Figure 4 for ranges.)
9
Insignificant for pressure ranges above 40 mbar | 4 kPa | 20 inH
2
O.