Submittal Sheet

SMARTVFD HVAC2
31-00109EF—01 14
FEATURES / FUNCTIONS
Easy to set-up features
Table 17.
Compact and robust design with easy installation
Table 18.
Uninterruptible operation functions
Table 19.
Feature Functions Benefit
30 second Start-up wizard Quick wizard allows you to set up basic parameters upon first
power up of drive.
Speeds up drive set-up for
basic parameters. Includes
fire mode set-up if needed.
“Keypad – Remote”
Operation
Push the Local/Remote button. Single button operation to
change the control to
manual (keypad) and back.
Useful function when
commissioning and
testing applications
Quick Setup Menu Only the most commonly used parameters are visible in basic
view to provide easier navigation. The full view can be seen after
P16.2 in HVAC2 Parameter conceal is deactivated by changing
the value to 0.
Easy navigation through
the most common
parameters
SmartVFD Commissioning
Tool
1. Parameter sets can be uploaded and downloaded with
this tool.
2. Easy to use PC-tool for commissioning the SmartVFD
Inverters. Connection with HVFDCABLE and MCA adapter,
(HVFDCDMCAKIT/U), to the USB port of the PC. PC-tools
available for download free of charge from
https://customer.honeywell.com/en-US/support/com-
mercial/software/vfds/Pages/default.aspx
Parameter copying easily
from 1 inverter to another.
Easy download of
parameter sets created
with PC-tool
Parametering with PC
Saving settings to PC
Comparing parameter
settings
Feature Functions Benefit
Compact size Minimum free space above and below the drive is required for
cooling airflow.
Minimum space
requirements
Integrated RFI-filters Units with E2 suffix in the part number comply with EN61800-
3 category C2 as standard. This level is the required level for
public electricity networks such as buildings.
Easy selection and
installation of products.
Space savings
Cost savings
Max. ambient temperature
+ 122 °F (some exceptions)
High maximum ambient operating temperature Uninterruptible operation
Side by side mounting with
screws or DIN-rail as
standard
SmartVFD HVAC2 MI1-MI3 can be mounted side by side with
no space between the units either with screws or on DIN-rail
as standard. (For MI4-MI5, side to side installation is not
allowed and there is no DIN rail option.)
Dimensions for screw mounting can be found also on the back
of the inverter.
Easy installation
Space savings
Feature Functions Benefit
Overtemperature
ride-through
Automatically adjusts switching frequency to adapt to
unusual increase in ambient
Uninterruptible operation
Power ride-through Automatically lowers motor speed to adapt to sudden voltage
drop such as power loss
Uninterruptible operation
Auto restart function Auto restart function can be configured to make VFD restart
automatically once fault is addressed
Uninterruptible operation