Brochure

10
NEMA 1
Frame Size HP And Voltage
Configuration
Dimensions (in) Weight (lb)
208/230 VAC 460 VAC W H D
4 0.75-3 HP 1.5-7.5 HP
Drive alone 5 12.9 7.5 13.2
Disconnect 8.9 31.9 10.3 33
2-Contactor 8.9 31.9 9.6 38
3-Contactor 8.9 38.9 10.3 44
3-Contactor with Auto-Bypass 8.9 38.9 10.3 46
5
5 HP
7.5 HP
10 HP
10 HP
15 HP
20 HP
Drive alone 5.7 16.5 8.4 22
Disconnect 8.9 34.7 10.3 43
2-Contactor 8.9 34.7 9.6 48/50/50
3-Contactor 8.9 41.7 10.3/10.3/10.8 55.5/57/59.5
3-Contactor with Auto-Bypass 8.9 41.7 10.3/10.3/10.8 56/57.5/60
6
15 HP
20 HP
25 HP
30 HP
40 HP
Drive alone 7.7 21.9 9 44.1
Disconnect 12.4 45.1 11.3 50
2-Contactor 12.4 45.1 10.1 55/59
3-Contactor 12.4 55.2 11.3 94.5/98.5/105.5
3-Contactor with Auto-Bypass 12.4 55.2 11.3 96.5/100.5/107.5
7
25 HP
30 HP
40 HP
50 HP
60 HP
75 HP
Drive alone 9.3 25.4 10.2 82.7
Disconnect 20.8 51.5 13.2 100
2-Contactor 20.8 51.5 12.2 169/179/189
3-Contactor 20.8 59 13.2 175/184/195
3-Contactor with Auto-Bypass 20.8 59 13.2 177/186/197
8
50 HP
60 HP
75 HP
100 HP
125 HP
150 HP
Drive alone 11.4 38 13.5 154.3
Disconnect 25 60 16.2 200
2-Contactor 25 60 15.2 250/265/280
3-Contactor 25 70 16.2 285/295/331
3-Contactor with Auto-Bypass 25 70 16.2 287/297/333
9 100-125 HP 200-250 HP Drive alone 18.9 45.3 14.4 238.1
Smart Selection
Honeywell SmartVFD
HVAC and SmartVFD
BYPASS are smaller,
sleeker and require a
smaller footprint than
other manufacturers.
They are specifically
designed for your
HVAC application.
VFD Pricing/Job Estimating Tools
For additional tools you can use for the selection and pricing of VFDs, click on the
“Commercial Components Estimating Tools” link at customer.honeywell.com.
NEMA 12
Frame
Size
HP And Voltage
Configuration
208/230 Vac
Dimensions (in) & Weight (lb)
460 Vac
Dimensions (in) & Weight (lb)
208/230 VAC 460 VAC W H D lb W H D lb
4 0.75-3 HP 1.5HP-7.5 HP
Drive alone 5 12.9 7.5 13.2 5 12.9 7.5 13.2
Disconnect 12 37.5 11 40 12 37.5 11 40
2-Contactor 16 37.5 11 55 16 37.5 11 53
3-Contactor 16 37.5 11 55 16 37.5 11 53
3-Contactor with Auto-Bypass 16 37.5 11 55 16 37.5 11 53
5 5-10 HP
10 HP
15 HP
20 HP
Drive alone 5.7 16.5 8.4 22 5.7 16.5 8.4 22
Disconnect 12 41 11 72 12 41 11 72
2-Contactor 16 41/41/45 11 70/70/84 16 41/41/45 11 64/64/76
3-Contactor 16 41/41/45 11 70/70/84 16 41/41/45 11 64/64/76
3-Contactor with Auto-Bypass 16 41/41/45 11 70/70/84 16 41/41/45 11 64/64/76
6 15-20 HP
25 HP
30 HP
40 HP
Drive alone 7.7 21.9 9 44.1 7.7 21.9 9 44.1
Disconnect 12 46.5 13 120 12/12/16 46.5 13 120/120/136
2-Contactor 16/20 50.5/54.5 13 125/140 16/16/20 50.5/50.5/54.5 13 120/120/136
3-Contactor 16/20 50.5/54.5 13 125/140 16/16/20 50.5/50.5/54.5 13 120/120/136
3-Contactor with Auto-Bypass 16/20 50.5/54.5 13 125/140 16/16/20 50.5/50.5/54.5 13 120/120/136
7 25-40 HP
50 HP
60 HP
75 HP
Drive alone 9.3 25.4 10.2 82.7 9.3 25.4 10.2 82.7
Disconnect 16 50.5 13.5 145/160/175 16 50.5 13.5 145/160/175
2-Contactor 20/24/30 58.5/65.5/70.5 13.5 160/175/200 20/24/30 58.5/65.5/70.5 13.5 150/165/193
3-Contactor 20/24/30 58.5/65.5/70.5 13.5 160/175/200 20/24/30 58.5/65.5/70.5 13.5 150/165/193
3-Contactor with Auto-Bypass 20/24/30 58.5/65.5/70.5 13.5 160/175/200 20/24/30 58.5/65.5/70.5 13.5 150/165/193
8 50-75 HP
100 HP
125 HP
150 HP
Drive alone 11.4 38 13.5 154.3 11.42 38.03 13.5 154.3
Disconnect
Contact Customer Care Contact Customer Care
2-Contactor
3-Contactor
3-Contactor with Auto-Bypass
9 100-125 HP 180-220 HP Drive alone 18.9 45.3 14.4 238.1 14.37 45.27 18.9 238.1
NEMA 3R
Frame
Size
HP And Voltage
Configuration
Dimensions (in) Weight (Ib)
208/230 VAC 460 VAC W H D
4 0.75-3 HP 1.5-7.5 HP
Drive alone 20.5 20 10.5 39
Disconnect 20.5 20 12 43
2-Contactor 24.5 24 10.5 49
3-Contactor 24.5 24 12 54
3-Contactor with Auto-Bypass 24.5 24 12 54
5 5-10 HP 10-20 HP
Drive alone 20.5 24 10.5 58
Disconnect 20.5 24 12 61
2-Contactor 24.5 24 10.5 72
3-Contactor 28.5 30 12 78
3-Contactor with Auto-Bypass 28.5 30 12 78
6 15-20 HP 25-40 HP
Drive alone 28.5 36 10.5 80
Disconnect 28.5 36 12 88
2-Contactor 28.5 36 10.5 118
3-Contactor 34.5 36 12 124
3-Contactor with Auto-Bypass 34.5 36 12 124
7 25-40 HP 50-75 HP
Drive alone 28.5 48 12.5 130
Disconnect 28.5 48 14 149
2-Contactor 28.5 48 12.5 185
3-Contactor 40.5 48 14 193
3-Contactor with Auto-Bypass 40.5 48 14 193
8 50-75 HP 100-150 HP
Drive alone 40.5 60 12.5 299
Disconnect 40.5 60 14 340
2-Contactor 40.5 60 12.5 430
3-Contactor 40.5 60 14 440
3-Contactor with Auto-Bypass 40.5 60 14 440