Submittal Sheet

10
NEMA 1
Frame Size HP And Voltage
Configuration
Dimensions (in) Weight (lb)
208/230 VAC 460 VAC W H D
4 0.753 HP 1.57.5 HP
Drive alone 5 12.9 7.5 13.2
Disconnect 8.9 31.9 10.3 33
2Contactor 8.9 31.9 9.6 38
3Contactor 8.9 38.9 10.3 44
3Contactor with AutoBypass 8.9 38.9 10.3 46
5
5 HP
7.5 HP
10 HP
10 HP
15 HP
20 HP
Drive alone 5.7 16.5 8.4 22
Disconnect 8.9 34.7 10.3 43
2Contactor 8.9 34.7 9.6 48/50/50
3Contactor 8.9 41.7 10.3/10.3/10.8 55.5/57/59.5
3Contactor with AutoBypass 8.9 41.7 10.3/10.3/10.8 56/57.5/60
6
15 HP
20 HP
25 HP
30 HP
40 HP
Drive alone 7.7 21.9 9 44.1
Disconnect 12.4 45.1 11.3 50
2Contactor 12.4 45.1 10.1 55/59
3Contactor 12.4 55.2 11.3 94.5/98.5/105.5
3Contactor with AutoBypass 12.4 55.2 11.3 96.5/100.5/107.5
7
25 HP
30 HP
40 HP
50 HP
60 HP
75 HP
Drive alone 9.3 25.4 10.2 82.7
Disconnect 20.8 51.5 13.2 100
2Contactor 20.8 51.5 12.2 169/179/189
3Contactor 20.8 59 13.2 175/184/195
3Contactor with AutoBypass 20.8 59 13.2 177/186/197
8
50 HP
60 HP
75 HP
100 HP
125 HP
150 HP
Drive alone 11.4 38 13.5 154.3
Disconnect 25 60 16.2 200
2Contactor 25 60 15.2 250/265/280
3Contactor 25 70 16.2 285/295/331
3Contactor with AutoBypass 25 70 16.2 287/297/333
9 100125 HP 200250 HP Drive alone 18.9 45.3 14.4 238.1
Honeywell SmartVFD
HVAC and SmartVFD
BYPASS are smaller,
sleeker and require a
smaller footprint than
other manufacturers.
They are specifically
designed for your
HVAC application.
NEMA 12
Frame
Size
HP And Voltage
Configuration
208/230 VAC
Dimensions (in) & Weight (lb)
460 VAC
Dimensions (in) & Weight (lb)
208/230 VAC 460 VAC W H D lb W H D lb
4 0.753 HP 1.57.5 HP
Drive alone 5 12.9 7.5 13.2 5 12.9 7.5 13.2
Disconnect 12 37.5 11 40 12 37.5 11 40
2Contactor 16 37.5 11 55 16 37.5 11 53
3Contactor 16 37.5 11 55 16 37.5 11 53
3Contactor with AutoBypass 16 37.5 11 55 16 37.5 11 53
5 510 HP
10 HP
15 HP
20 HP
Drive alone 5.7 16.5 8.4 22 5.7 16.5 8.4 22
Disconnect 12 41 11 72 12 41 11 72
2Contactor 16 41/41/45 11 70/70/84 16 41/41/45 11 64/64/76
3Contactor 16 41/41/45 11 70/70/84 16 41/41/45 11 64/64/76
3Contactor with AutoBypass 16 41/41/45 11 70/70/84 16 41/41/45 11 64/64/76
6 1520 HP
25 HP
30 HP
40 HP
Drive alone 7.7 21.9 9 44.1 7.7 21.9 9 44.1
Disconnect 12 46.5 13 120 12/12/16 46.5 13 120/120/136
2Contactor 16/20 50.5/54.5 13 125/140 16/16/20 50.5/50.5/54.5 13 120/120/136
3Contactor 16/20 50.5/54.5 13 125/140 16/16/20 50.5/50.5/54.5 13 120/120/136
3Contactor with AutoBypass 16/20 50.5/54.5 13 125/140 16/16/20 50.5/50.5/54.5 13 120/120/136
7 2540 HP
50 HP
60 HP
75 HP
Drive alone 9.3 25.4 10.2 82.7 9.3 25.4 10.2 82.7
Disconnect 16 50.5 13.5 145/160/175 16 50.5 13.5 145/160/175
2Contactor 20/24/30 58.5/65.5/70.5 13.5 160/175/200 20/24/30 58.5/65.5/70.5 13.5 150/165/193
3Contactor 20/24/30 58.5/65.5/70.5 13.5 160/175/200 20/24/30 58.5/65.5/70.5 13.5 150/165/193
3Contactor with AutoBypass 20/24/30 58.5/65.5/70.5 13.5 160/175/200 20/24/30 58.5/65.5/70.5 13.5 150/165/193
8 5075 HP
100 HP
125 HP
150 HP
Drive alone 11.4 38 13.5 154.3 11.42 38.03 13.5 154.3
Disconnect
Contact Customer Care Contact Customer Care
2Contactor
3Contactor
3Contactor with AutoBypass
9 100125 HP 180220 HP Drive alone 18.9 45.3 14.4 238.1 14.37 45.27 18.9 238.1
NEMA 3R
Frame
Size
HP And Voltage
Configuration
Dimensions (in) Weight (Ib)
208/230 VAC 460 VAC W H D
4 0.753 HP 1.57.5 HP
Drive alone 20.5 20 10.5 39
Disconnect 20.5 20 12 43
2Contactor 24.5 24 10.5 49
3Contactor 24.5 24 12 54
3Contactor with AutoBypass 24.5 24 12 54
5 510 HP 1020 HP
Drive alone 20.5 24 10.5 58
Disconnect 20.5 24 12 61
2Contactor 24.5 24 10.5 72
3Contactor 28.5 30 12 78
3Contactor with AutoBypass 28.5 30 12 78
6 1520 HP 2540 HP
Drive alone 28.5 36 10.5 80
Disconnect 28.5 36 12 88
2Contactor 28.5 36 10.5 118
3Contactor 34.5 36 12 124
3Contactor with AutoBypass 34.5 36 12 124
7 2540 HP 5075 HP
Drive alone 28.5 48 12.5 130
Disconnect 28.5 48 14 149
2Contactor 28.5 48 12.5 185
3Contactor 40.5 48 14 193
3Contactor with AutoBypass 40.5 48 14 193
8 5075 HP 100150 HP
Drive alone 40.5 60 12.5 299
Disconnect 40.5 60 14 340
2Contactor 40.5 60 12.5 430
3Contactor 40.5 60 14 440
3Contactor with AutoBypass 40.5 60 14 440
| SMARTVFD HVAC AND BYPASS
Smart Selection
VFD Pricing/Job Estimating Tools
For additional tools you can use for the selection and pricing of VFDs,
see CPQ.Honeywell.com.