User manual

3 - 20
another. Consequently, any desired changes to either the retail or warehouse area would apply to all scanners in that particular
work group. Honeywell’s online configuration tool, EZConfig-Scanning (page 11-2), makes it easy for you to program your sys-
tem for use with multiple scanners and multiple work groups.
The scanner keeps a copy of the menu settings it is using. Whenever the scanner is connected or reconnected to a base or an
Access Point, the scanner is updated with the latest settings from the base or Access Point for its work group. The scanner also
receives menu setting changes processed by the base or Access Point. If a scanner is removed from a base or an Access Point
and placed into another base or linked to another Access Point, it will be updated with the new base/Access Point settings for
whatever work group to which that the scanner was previously assigned. For example, if the scanner was in work group 1 linked
to the first base, it will be placed in work group 1 in the second base with the associated settings.
Application Work Group Selection
This programming selection allows you to assign a scanner to a work group by scanning the bar code below. You may then
program the settings (e.g., beeper volume, prefix/suffix, data formatter) that your application requires.
Default = Group 0.
Resetting the Factory Defaults: All Application Work Groups
The following bar code defaults all of the work groups to the factory default settings.
* Group 0
Group 1
Group 2
Group 3
Group 4
Group 5
Group 6
Factory Default Settings:
All Work Groups
PAPDFT&