User manual

4 - 10
Poor Quality PDF Codes
This setting improves the scanner’s ability to read damaged or badly printed PDF codes by combining information from mul-
tiple images. When Poor Quality PDF On is scanned, poor quality PDF code reading is improved, but the scanner’s snap-
piness is decreased, making it less aggressive when reading good quality bar codes. This setting does not affect 1D bar
code reading. Default = Poor Quality PDF Reading Off.
CodeGate
®
When CodeGate is On, the trigger is used to allow decoded data to be transmitted to the host system. The scanner remains on,
scanning and decoding bar codes, but the bar code data is not transmitted until the trigger is pressed. When CodeGate is Off,
bar code data is transmitted when it is decoded. Default = CodeGate Off Out-of-Stand.
Streaming Presentation Mode
When in Streaming Presentation mode, the scanner’s aimer goes out after a short time, but the scan illumination remains on all
the time to continuously search for bar codes. Two modes are available, Normal and Enhanced. Normal mode offers good
scan speed and the longest working ranges (depth of field). Enhanced mode will give you the highest possible scan speed but
slightly less range than Normal mode. Enhanced mode is best used when you require a very fast scan speed and don’t require
a long working range.
Note: Granit 1980i and 1981i do not support Enhanced Streaming Presentation Mode.
Poor Quality PDF Reading On
* Poor Quality PDF Reading Off
* CodeGate Off
Out-of-Stand
CodeGate On
Out-of-Stand
Streaming Presentation Mode
- Normal
Streaming Presentation Mode
- Enhanced