Aquastat Controllers L4006; L6006 Aquastat® Controller Aquastat® Controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. • Totally enclosed Micro Switch® snap-acting switches operate on temperature rise to setpoint. • Visible control point scale and external adjustment screw permit easy setting. • Horizontal or vertical insertion of the sensing element.
Aquastat Controllers Product Number Application (F) Well Spud Size Capillary Length (F) (inch) 3 in. 76 mm SPST, contacts break Horizontal or on temperature rise. Vertical Heat-conductive compound; Stop factoryset at 240 F (116 C) * L4006A1959 High or Low limit 40 F to 180 F — 3 in. 76 mm SPST, contacts break Horizontal or on temperature rise. Vertical Heat-conductive compound * L4006A1967 High or Low limit 100 F to 38 C to 5 F to 3 C to 1/2 in. 240 F 116 C 30 F adj. 17 C adj.
Aquastat Controllers L4008; L6008 Remote Bulb Controller Aquastat® Controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. • Remote temperature sensing element detects and responds rapidly to temperature changes. • Totally enclosed Micro Switch® snap-acting switch. • Visible control point scale and external adjustment screw permit easy setting.
Aquastat Controllers WELL-CLAMP SCREW KNOCKOUT FOR 1/2 INCH CONDUIT (6) 3/4-14 NPT Residential Combustion Controls Dimensions in inches (millimeters) Indoor Air Quality The L4103A,B is an immersion-type controller for oil-fired water heaters. The Aquastat® Controller senses water temperature and cycles the burner through the oil primary. The high-limit controller breaks the circuit to the burner on a temperature rise past the factory-set setpoint.
Aquastat Controllers L8100 Aquastat® Controller L8100A,B, and C are immersion type controllers for regulating and limiting the tank temperature in water heaters. As the water temperature rises past the setpoint, the controller switches off the gas valve. • Regulates temperature and provides energy cutoff (ECO) action on a temperature rise past the setpoint. • Includes a second sensing element that senses average water temperature to minimize stacking.
Aquastat Controllers Maximum Ambient Temperature: 150 F at switches; 265 F at sensing element (66 C at switches; 129 C at sensing element) Operating Range, High Limit: 130 F to 240 F (54 C to 116 C) Operating Range, Low Limit: 110 F to 220 F (43 C to 104 C) Operating Humidity Range (% RH): 0 to 95% RH, non-condensing Full Load: 5.1A @ 240 Vac; 8A @ 120 Vac Locked Rotor: 30.6A @ 240 Vac; 48A @ 120 Vac Millivolt: 0.25 A @ 0.25 to 12 Vdc Approvals: Canadian Standards Association: Certified: File No.
Aquastat Controllers JUNCTION BOX R4184D PROTECTORELAY™ CONTROL SS BLACK 1K2 ORANGE 1K CAD CELL F SOLID STATE SWITCH BURNER MOTOR OIL VALVE 1K1 SAFETY SWITCH HEATER IGNITION WHITE F L1 (HOT) 1 L2 CIRCULATOR B 2 4 24V THERMOSTAT 3 1 2 B W 1R1 R L6081A T 1R T 1 RA89A SWITCHING RELAY R JUMPER ADDED POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2 B TERMINALS ARE TAB TERMINALS. 196 customer.honeywell.
Aquastat Controllers Vertical Hydronic Controls Horizontal Voltage: 120 Vac Maximum Ambient Temperature: 150 F at switches, 265 F at sensing element. (66 C at switches, 129 C at sensing element.) Operating Range, High Limit: 130 F to 240 F adj. (54 C to 116 C adj.) Operating Range, Low Limit: 110 F to 220 F adj. (43 C to 104 C adj.) Maximum Operating Pressure: 200 psi on outside of immersion well, 100 psi on capsule if inserted directly.
Aquastat Controllers Dimensions in inches (millimeters) ZONE 2 THERMOSTAT ZONE 1 THERMOSTAT V8043F TH TR TH V8043F TH TR TR TR TH 2 L8124G,L 3 G TV T Z 1 L1 (HOT) 2 L2 1 1K 1K1 R W B ZR LOW LIMIT/ CIRCULATOR ZC B 1K2 HIGH LIMIT 4 R LINE VOLTAGE OIL BURNER RELAY OR GAS VALVE B1 LOW VOLTAGE THERMOSTAT B2 C2 L8124A,C 2 G T T C1 1 L1 (HOT) 2 L2 1K R W B LOW LIMIT/ CIRCULATOR LINE VOLTAGE CIRCULATOR 2 UP TO TWO V8043F ZONE VALVES CAN BE POWERED WITH L8124G,L.
Aquastat Controllers Home Controls LOW VOLTAGE THERMOSTAT LOW VOLTAGE THERMOSTAT L8124B L8124E 2 2 G G T T TV 1 L1 (HOT) 2 L2 Z 1K 1 L1 (HOT) 2 L2 1 Indoor Air Quality T 1 1K2 1K W 1K2 1K3 R B W 1K1 R B 1K1 LINE VOLTAGE CIRCULATOR R HIGH LIMIT LINE VOLTAGE CIRCULATOR R HIGH LIMIT C1 B C1 B C2 C2 3 3 2 TH B1 TR B2 TH B2 TH POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. POWERPILE® CONTROL CASE MUST BE CONNECTED TO EARTH GROUND.
Aquastat Controllers L8148 Aquastat® Relay Immersion-type controllers that combine high limit protection with switching relay control of burner and circulator motors. • High limit opens burner circuit only. • Include transformer and accessory terminals for adding a remote low limit controller. • Case available for horizontal or vertical mounting. • Requires a 24 Vac thermostat with heat anticipator set at 0.2A. • TRADELINE models include well adapter, tube of heat conductive compound and range stops.
Aquastat Controllers Product Number Application (F) (inch) L8148E1299 (inch) Switching Action (mm) Mounting Includes High Limit 15 F fixed 4 1/2 in. 114 mm 1 1/2 in. to 3 38 mm to 76 in. less well mm less well SPST: High Vertical Limit & Mount Circulator 50 VA transformer and heat conductive compound. Aquastat Relay 8 F fixed 4 1/2 in. 114 mm 1 1/2 in. to 3 38 mm to 76 in. less well.
Aquastat Controllers L1 L2 HOT 1 24V THERMOSTAT 24V THERMOSTAT 3 W G L1 L2 T T R L8148A L6006 B LOW LIMIT CONTROLLER 2 R 3 W B HIGH LIMIT B L6006 LOW LIMIT CONTROLLER PP 4 C2 PP B2 B1 TO LINE VOLTAGE OIL BURNER RELAY OR GAS VALVE CIRCULATOR W T Z 2 TP 3 B MILLIVOLTAGE POWERPILE® GAS VALVE R C1 TV HIGH LIMIT R C1 C2 TH2 B1 B2 TH1 B3 L2 L1 5 1 B JUMPER L1 L2 (HOT) THTR T T L8148J L1 R CIRCULATOR 4 G L1 G TH TR LOW VOLTAGE GAS VALVE (eg, VR8300) G L8148
Aquastat Controllers Operating Humidity Range (% RH): 0 to 95% RH, non-condensing Electrical Ratings (burner AFL): 7.4 A @ 120 Vac (burner ALR): 44.4 A inrush (circulator AFL): 7.4 A @ 120 Vac (circulator ALR): 44.4 A inrush Hydronic Controls Dimensions, Approximate: 7 1/8 in. high x 4 1/4 in. wide x 2 5/8 in.
Aquastat Controllers R8182 Combination Protectorelay® and Hydronic Heating Controllers Immersion type Aquastat controller and oil burner primary control provides high limit and low limit/circulator control for oil-fired hydronic heating systems. • Use in intermittent ignition applications. • Capable of zone control with zone valves. • Circulator zone control with ZC and ZR terminals on R8182D,E,H,J. 8*Flame failure during the running cycle results in a 45 second attempt to restart.
Aquastat Controllers Insulation Depth (mm) Home Controls Differential Temperature (F) (inch) R8182D1079 High limit: 10 F fixed; Low limit/circulator: 10 F to 25 F adj. 1 1/2 in. 38 mm Vertical Mount Auxiliary ZC and ZR terminals may be used to provide circulator zone control through an R845A Switching Relay. Heat-conductive compound and vertical case. Mounting Includes * R8182D1111 High limit: 10 F fixed; Low limit/circulator: 10 F to 25 F adj. 1 1/2 in.
Well Assemblies Well Assemblies Product Number Description Shell Spud Insertion (internal Thread Materials Length diameter) Size Includes 121371A Copper. Bulb size: 3/8 in. x Copper 3 in. (10 mm x 76 mm). Well size:3 in. (76 mm) insertion, 1 1/2 in. NPT. Includes mounting clamp. 1 1/2 in. 3/8 in. 1/2 in.
AQUATROL Zoning System Home Controls AQ250 Electronic Relay Boiler Control Panel for Hydronic Zoning System Commercial Components Replacement Parts Zone pumps or 2-wire 4 valves (line voltage) 120 Vac/250 Vac 120 Vac/250 Vac 5A, 1/3HP 5A, 1/3HP AQ15000B boiler control module AQ12C11 supply/return/mixed loop sensor AQ10X38 24 Vac 38 VA transformer AQ15540B 4-zone pump expansion module AQ25044B Zone valves with end 4 switches 120 Vac/250 Vac 120 Vac/250 Vac 5A, 1/3HP 5A, 1/3HP AQ15000B boiler contro
AQUATROL Zoning System AQ25A Programmable Relay Control Panel for Hydronic Zoning System • • • • • • The AQ25A family of AQUATROL Programmable Relay Boiler Controls provides simplified, energy-efficient control of singletemperature, residential hydronic heating systems.
AQUATROL Zoning System • • • • • Industrial Combustion Controls 209 Pneumatic Controls Approvals: Canadian Standards Association: CSA C/US Certified to CSA and UL Standards, File No. LR76030 Commercial Components Return Minimum Control Temperature: 80 F to 180 F (27C to 82C) Pump/Valve exercise: 30 seconds per 2 weeks of space heating inactivity Auxiliary Pump Output Rating: Dry contact output, 120 Vac/250 Vac 5A, 1/3 HP Auxiliary Low Voltage Output Rating: 24 Vac, 0.
AQUATROL Zoning System Product Number Type of Zoning Number of Devices Zones Controlled Controlled AQ25110B None AQ25142B AQ25144B 210 120 Vac/250 120 Vac/250 Vac Vac 5A, 1/3HP 5A, 1/3HP AQ15100B boiler reset module AQ12C11 supply/return/mixed loop sensor AQ12C10 outdoor sensor AQ10X38 24 Vac 38 VA transformer Pumps or 2-wire 4 valves 120 Vac/250 120 Vac/250 Vac Vac 5A, 1/3HP 5A, 1/3HP AQ15100B boiler reset module AQ12C11 supply/return/mixed loop sensor AQ12C10 outdoor sensor AQ10X38 24 Vac 38 VA
AQUATROL Zoning System • • • • • • • Industrial Combustion Controls 211 Pneumatic Controls Approvals: Canadian Standards Association: CSA C/US Certified to CSA and UL Standards, File No. LR76030 Commercial Components Secondary Pump Output Rating: 120 Vac 5A, 1/3HP Auxiliary Pump Output Rating: Dry contact output, 120 Vac/250 Vac 5A, 1/3 HP Auxiliary Low Voltage Output Rating: 24 Vac, 0.
AQUATROL Zoning System Type of Zoning Devices Controlled Mixing Valve Number of Floating Zones Output Controlled (Com,O,C) Mixing Valve Modulating Boiler Pump Output Output Rating DHW Pump/ Valve Output Rating Replacement Parts AQ25242B Zone pumps or 2-wire valves (line voltage) 4 24Vac rated dry contacts 0-10 Vdc 120 Vac/250 Vac 5A, 1/3HP 120 Vac 5A, 1/3HP AQ15200B universal injection/mixing boiler reset module AQ12C11 supply/return/mixed loop sensor AQ12C10 outdoor sensor AQ10X38 24 Vac 38 VA t
AQUATROL Zoning System Home Controls AQ255 and AQ257 Zoning Expansion Panel for Hydronic Zoning System Building Automation Number of Weight Zones Controlled (kg) Water Controls Approvals: Canadian Standards Association: CSA C/US Certified to CSA and UL Standards, File No.
AQUATROL Zoning System AQ2000 Series Replacement Control Modules Dimensions, Approximate AQ15000B and AQ15400B: 3 1/2 in wide x 2 1/2 in high x 4 1/4 in wide (9 cm wide x 94 cm high x 10.09 cm deep) AQ15100B, AQ15200B and AQ15A00B: 7 1/8 in wide x 2 1/2 in high x 4 1/4 in deep (18 cm wide x 94 cm high x 10.
AQUATROL Zoning System Home Controls AQ2000 Series Accessories and Replacement Parts Product Number Description Replacement transformer module for AQ250, AQ25A, AQ251, AQ252, AQ254, AQ257 and AQ25742B series control and zoning panels. It can be used to add an additional 38 VA power per transformer to drive high VA devices. AQ11D10 Replacement enclosure for AQ25400B, AQ25542B, AQ25742B, AQ25744B, AQ25582B panels, Consists of case, cover, and DIN rail for mounting of transformer, control or zoning modules.
AQUATROL Zoning System AQ1000TN2 Non-Programmable Communicating Thermostat The AQ1000TN2 thermostat is used to control the ambient air temperature or floor temperature in hydronic heating applications. It communicates with and is powered by an AQ2000 series zoning module to provide zoning control. • 2-wire polarity-insensitive non-programmable network communicating thermostat. • Liquid crystal display with user buttons . • Outdoor, indoor and floor temperature displays.
AQUATROL Zoning System Indoor Air Quality The AQ1000TP2 thermostat is used to control the ambient air temperature or floor temperature in hydronic heating applications. It communicates with and is powered by an AQ2000 series zoning module to provide zoning control.