Datasheet

MIP SERIES
Heavy Duty, Media-Isolated Pressure Transducers
1 bar to 60 bar | 15 psi to 870 psi
DESCRIPTION
The MIP Series offers a heavy duty,
media-isolated pressure transducer in a
compact, stainless steel construction for
use with a wide range of media including
aggressive fluids and water. The MIP
Series provides a cost-competitive
solution for wide-ranging potential
applications in tough environments.
VALUE TO CUSTOMERS
Total Error Band (TEB) ±0.75 %FSS
(Full Scale Span) from -40°C to
125°C: Provides true measurement
performance over the compensated
temperature range; small error
promotes system uptime and
efficiency (see Figure 4).
EMC performance: Operates reliably
in the presence of electromagnetic
fields, such as wireless signals, RF
communication, and electrical devices.
Hermetically welded design supports
almost any media without the use of an
internal seal. The sensors are designed to
be used in harsh environments that see
aggressive media.
PORTFOLIO
Honeywell offers a variety
of heavy duty pressure
transducers for potential use in
industrial and transportation
applications. To view the entire
product portfolio, click here.
DIFFERENTIATION
Diagnostics: Beneficial in applications
where the sensor functionality and
the need to know internal or external
failure modes is critical.
Great customer value: Multiple
configuration possibilities provide
flexibility of use in the application with
no up front NRE or tooling charges.
Durable: Provides the tough
environmental capabilities needed,
including long-term stability, insulation
resistance and dielectric strength,
external freeze-thaw resistance and
EMC performance.
32346591
Issue B
TABLE 1. POTENTIAL APPLICATIONS
INDUSTRY MEDIA
Industrial:
pumps
compressors
process
water, hydraulic fluids
compressed air
food, beverage, oil, gas, steam
HVAC/R
refrigerants (butane, propane, ammonia, CO
2
, R134A, R407C,
R410A, R448A/Solstice
®
N40, R32 and R1234ze, R1234yf,
glycol + water
Transportation gasoline, diesel fuel, engine oil, brake fluid, coolants, CNG
Medical O
2
, N
2
, CO
2
, N
2
O, air
FEATURES
Rugged, stainless steel construction
Ratiometric output: 0.5 Vdc to 4.5 Vdc
Operating temperature: -40°C to 125°C
Total Error Band up to ±0.75 %FSS
(-40°C to 125°C)
Industry-leading accuracy: ±0.15
%FSS BFSL
Long term stability: ±0.25 %FSS
Radiated immunity: 100 V/m
High burst pressure: 207 bar [3000 psi]
Drinking water approval: NSF/ANSI/CAN 61
CE, RoHS, REACH compliant
Mis-wiring protection
Over voltage protection ±40 Vdc
Certified to
NSF/ANSI/CAN 61