MS2420 / MS2430 Bar Code Scanner / Diva Scale Installation and User’s Guide
Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of HII.
Table of Contents Introduction Manual Scope .................................................................................................................................................1 Product Overview ...........................................................................................................................................1 Base Kit Components .....................................................................................................................................
Scanner Operation Scan Zone ....................................................................................................................................................33 Wake Activation Area (Photocell LED Output).............................................................................................. 35 Changing the Wake Area Sensitivity Level ........................................................................................ 36 Audible Indicators ........................................
Introduction Manual Scope This guide provides information on the installation, setup, and operation of Honeywell’s MS2420 and MS2430 scanner/Diva scale unit. It is designed to be used in conjunction with MetroSelect® Configuration Guide (PN 00-02407x) and the MS2x20 Stratos Series Scanner/Diva Scale Configuration Addendum (PN 00-02272x). Product manuals are also available for download in Adobe® Acrobat® file format at www.honeywellaidc.com.
Base Kit Components Part # MS24x0-105Kz Description Scanner/Diva Scale 2 MS2420; 399 mm (15.7") 3 MS2430; 508 mm (20.0") D Diamonex Horizontal Window S Sapphire Horizontal Window x z 00-02407* MetroSelect® Configuration Guide 00-02272* MS2x20 Stratos Series Scanner/Diva Scale Configuration Addendum 00-05310* MS2420/MS2430 Scanner/Diva Scale Installation and User’s Guide * Guides also available for download at www.honeywellaidc.com.
Optional Accessories Part # 46-00980-R Description AC to DC Power Transformer - Regulated Output: +5V @ 4A +12V @ 0.
Optional Accessories Part # Description 46-00375 Remote Single Line Scale Display (lb.) (See Figure 1) 46-00376 Remote Single Line Scale Display (kg.) Dual Interval (See Figure 1) 46-01075 Remote Single Line Scale Display (kg.) Single Interval (See Figure 1) Other Four Line Scale Display currency lens overlay stickers are available. To order additional items or replacement parts, contact the dealer, distributor or call the customer service department.
Replacement Parts Part # Description Window types (Diamonex and Sapphire) are not interchangeable due to laser safety and/or scanner performance differences. Caution To change window type, the scanner must be returned to the manufacturer for reconfiguration.
General Precautions The following are some general precautions to remember when handling your MS2420/MS2430 series scanner. Do not turn the unit upside down with the platter in place. Figure 2 Do not press on the window in the replacement platter or the vertical window frame. Figure 3 Platter Removal No hardware or tools are required to remove the platter (see Figure 4). Refer to the Maintenance section of this manual for additional information on platter replacement.
Design Specifications Operational Light Source: VLD 650 nm Peak Laser Power: <1.5 mW Horizontal Depth of Field: 0 mm – 100 mm (0"- 4") for 0.33 mm (13 mil) Bar Code Vertical Depth of Field: 0 mm - 216 mm (0"- 8.5") for 0.33 mm (13 mil) Bar Code Scan: (Scan) Speed: 5400 Scan Lines per Second (Scan) Zone: 360° No. of Scan Lines: 54 (38 Horizontal / 16 Vertical) Motor Speed: 6000 / 6000 RPM (Horizontal / Vertical ) Min Bar Width: 0.114 mm (4.
Electrical Voltage Supply: 4A @ +5V / 1.5A @ +12V Operating: 11.9 Watts Power: Standby: 3.25 Watts Operating: 1.7A @ 5.2V / 0.2A @ 12V Current: Standby: 0.6A @ 5.2V / 0.07A @ 12V DC Transformers: Class I; 5.2VDC @ 3.8A; 12VDC @ 0.8A For Regulatory Compliance Information, refer to pages 73 - 75. Scale Capacities Capacity: kg unit Minimum Increments: kg unit Maximum Static Weight: kg unit 6.0 / 15.0 kg lb. unit 15.0 / 30.0 lb. 0.002 / 0.005 kg lb. unit 0.005 / 0.01 lb. 75.0 kg lb. unit 150.0 lb.
Base Model Characteristics MS2420/MS2430 Scanner / Mettler-Toledo DIVA Scale Components* Figure 6.
MS2420/MS2430 Scanner / Mettler-Toledo DIVA Scale Components Item No.
MS2420/MS2430 Scanner / Mettler-Toledo DIVA Scale MS2420 Dimensions Figure 7. MS2420 Dimensions MS2430 Dimensions Figure 8. MS2430 Dimensions Specifications are subject to change without notice.
MS2420/MS2430 Scanner / Mettler-Toledo DIVA Scale Connector Panel Figure 9.
MS2420/MS2430 Scanner/Diva Scale Caution and Serial Number Labels Figure 10. MS2420/MS2430 Label Locations (Top) and Examples (Bottom) Caution: To maintain compliance with applicable standards, all circuits connected to the imager must meet the requirements for SELV (Safety Extra Low Voltage) according to EN/IEC 60950-1. To maintain compliance with standard CSA C22.2 No.
14
Installation Quick Installation Outline The following is a quick preview of the steps required for first time installations. Each item is discussed in detail later in this section. Determine clearance, ventilation and service access requirements. Determine checkout counter layout taking into account package flow, cable routing, and power requirements. Choose the mounting option which provides the best cable/power access and unit stability. Unpack the unit.
Site Requirements Service Access When routing and installing the cable(s) and power supply, make sure you leave access that these components may be swapped easily without the need to remove the unit from the checkout counter. When changing the StratosSWAP™ optics engine modules, removing the unit completely from the checkout counter is recommended. When calibrating or zeroing the scale, do not remove the unit from the checkout counter.
Unpacking the Unit 1. Make sure the shipping box is topside up before opening. 2. Remove the accessories box and check the box’s content for the following items. Product Manuals Power Supply Communication Cables Remote Scale Display (Optional) 3. Carefully remove the platter and store it in a safe location until the unit is properly installed into the checkout counter. Figure 11 4.
Unpacking the Unit MS2420/MS2430 Package Warning There is a protective film located on the topside platter surface, vertical scan windows outer surface, and the horizontal scan windows top surface. These protective films must be removed prior to performing any scanner operation (see Figure 14). Both foam wedges securing the scale arms during shipping must be removed or the scale will not function (see Figure 14)! Figure 14. Protective shipping foam and lining.
Installing the Unit in the Counter MS2420 Mounting Diagram Figure 16. MS2420 Mounting Diagram Specifications are subject to change without notice.
MS2430 Mounting Diagram (Two Point Support) Figure 17. MS2430 Mounting Diagram, Two Point Support Specifications are subject to change without notice.
MS2430 Mounting Diagram (Three Point Support) Figure 18. MS2430 Mounting Diagram, Three Point Support Specifications are subject to change without notice.
Cable Installation (Interface Specific) RS232 The following steps describe how to properly install the cables for an RS232 application. The scanner/Diva scale must then be configured to match the host’s RS232 parameters. Cable installation alone does not guarantee that the scanner will communicate properly with the host system.
Cable Installation (Interface Specific) RS232 9. Turn on the host system. 10. Scan the Recall Defaults bar code. Note: The Recall Defaults bar code is located in the MetroSelect Configuration Guide, under Need to Start Over (PN 00-02407x). 11. Configure the scanner to match the host system’s RS232 parameters. Note: Refer to the MetroSelect Configuration Guide (PN 00-02407x) under Section G: RS232 for enabling RS232 Mode (scan the recall defaults bar code first).
Cable Installation (Interface Specific) Full Speed USB The following steps describe how to properly install the cables for a Full Speed USB application. The scanner/Diva scale must then be configured to match the host’s USB parameters. Cable installation alone does not guarantee that the scanner will communicate properly with the host system.
Cable Installation (Interface Specific) Full Speed USB 9. Turn on the host system. 10. Configure the scanner to match the host system’s USB parameters. For Single Cable Applications: The IBM OEM Full Speed USB English and Metric bar codes are located in the MS2x20 Stratos Series Scanner/Diva Scale Configuration Addendum (PN 00-02272x) under Scanner Configuration Bar Codes: Single Cable Protocols for POS Compatibility, IBM OEM Full Speed USB.
Cable Installation (Interface Specific) Full Speed USB xx** Specifies international connection. See the Base Kit Components and Optional Accessories section of this guide for a complete listing. See power source caution statement on page 13 of this manual. Figure 20.
Cable Installation (Interface Specific) RS485 The following steps describe how to properly install the cables for a RS485 application. The scanner/Diva scale must then be configured to match the host’s RS485 parameters. Cable installation alone does not guarantee that the scanner will communicate properly with the host system. Note: Configuration bar codes are located in the MetroSelect Configuration Guide (PN 00-02407x) and the MS2x20 Stratos Series Scanner/Diva Scale Configuration Addendum (PN 00-02272x).
Cable Installation (Interface Specific) RS485 9. Turn on the host system. 10. Configure the scanner to match the host system’s RS485 parameters. For Single Cable Applications: The IBM 3rd Generation 46xx, English and Metric bar codes are located in the MS2x20 Stratos Series Scanner/Diva Scale Configuration Addendum (PN 00-02272x) under Scanner Configuration Bar Codes: Single Cable Protocols for POS Compatibility, IBM 3rd Generation 46xx.
Cable Installation (Secondary Honeywell Scanner) The following steps describe how to properly install the cables between a secondary Honeywell scanner and the MS2420/MS2430. The MS2420/MS2430 and the secondary scanner must then be configured to communicate properly. Cable installation alone does not guarantee that the MS2420/MS2430 will communicate properly with the host system and secondary scanner.
Cable Installation (Secondary Honeywell Scanner) † See Aux power notes on page 29 See power source caution statement on page 13 of this manual. Figure 22.
EAS Deactivation SW1 and SW2 are the switch banks inside the Checkpoint Device that set the deactivation range. The following is a list of Checkpoint recommended switch bank settings. Base Model MS2420 MS2430 Checkpoint Recommended Switch Bank Settings SW1 & SW2 switches 1 and 6 set to ON SW1 & SW2 switches 1 and 6 set to ON All MS2420/MS2430 models have a connector labeled EAS In on the bottom of the unit.
32
Scanner Operation Scan Zone Figure 25. Checker-Side (13 mil) Figure 26. Horizontal Left/Right (13 mil) Specifications are subject to change without notice. Typical scan zones shown.
Scan Zone Figure 27. Horizontal Direct (13 mil) Figure 28. Vertical Direct (13 mil) Specifications are subject to change without notice. Typical scan zones shown.
Wake Activation Area (Photocell LED Output) The MS2420/MS2430 scanner’s default power save mode† is Dual Action Power Save Mode #2 (see page 43). This power save mode turns the laser OFF after a configured period of non-use then turns the motor OFF after thirty-minute intervals. Any movement detected by the photocell in the activation area, shown below in grey, will cause the scanner to exit the power save mode.
Wake Activation Area Sensitivity (Photocell LED Output Range) Changing the Wake Area Sensitivity Level (Photocell LED Range Adjust) The MS2400 Series bar code scanner wake area sensitivity level can be set to the end users preference by scanning one of the Photocell Sensitivity adjustment bar codes below. *Max Photocell Sensitivity This feature enables the MS24xx to be at Max sensitivity or far sensing for the wake up photo transistor. ³ 2 2 1 2 0 0 * This is the default setting.
Audible Indicators When in operation the MS2420/MS2430 provides audible feedback that indicates the status of the unit and the current scan. Eight settings are available for the tone of the beep (normal, six alternate tones and no tone) plus three volume settings. To change the tone or volume, refer to the Changing the Beeper Tone & Volume section of this manual. One Beep When the scanner first receives power the blue LED will flash then the blue LED will stay on and the scanner will beep once.
Visual Indicators Blue LED is located near the bottom corner of the vertical output window on the MS2420/MS2430. When the scanner is ON, the flashing or constant, illumination of the LED indicates the status of the MS2420/MS2430 and the current scan. There is an additional amber LED next to the scale zero symbol on all MS2420/MS2430 models that include a scale (see Figure 32). No Blue LED The blue LED will not be illuminated if the scanner is not receiving power from the host or transformer.
Failure Modes Flashing Blue and One Razzberry Tone This indicates that the scanner has experienced a laser subsystem failure. The scanner will try up to three times to correct the failure condition. If the laser subsystem continues to fail, that subsystem (horizontal or vertical) will be shut down and an error indication will be shown on the Diagnostic Indicator Display. This error stays on the display until corrected.
Diagnostic Indicator Display There is a two-digit error code display located under horizontal output window near the top of the platter (see figure below). Figure 31. Error Code Display The following is a list of possible error codes and their meanings. Some errors will require immediate scanner maintenance. Error Code 01 40 Description Reserved 02 RAM ERROR – The scanner’s Random Access Memory (RAM) is tested as faulty. Return the unit for repair at an authorized service center.
Diagnostic Indicator Display Error Code Description 09 COPROCESSOR COMMUNICATION ERROR – The main microprocessor is not communicating with the interface coprocessor. The interface coprocessor may be in a fault condition with the host or just not able to respond. This error may appear when the scanner is configured for USB or RS485 interface applications or during an attempt to update the interface software through the flash utility. The unit should be repaired at an authorized service center.
Diagnostic Indicator Display Error Code Description 26 LASER #3 (LEFT HORIZONTAL) HIGH CURRENT WARNING – The laser in the vertical scanning subsystem is drawing excessive current. This could be a warning for a future total failure. Have the unit checked at an authorized service center when convenient. 27 LASER #1 (VERTICAL) UNDERCURRENT WARNING – The laser in the vertical scanning subsystem is drawing too little current. The laser is probably not on.
Power Save Modes The MS2420/MS2430 has five configurable power save modes. Refer to the MetroSelect Configuration Guide for additional information on Power Save Modes. 1. Blink Power Save Mode: Blinks the laser OFF and ON after a configured period of non-use. When the scanner recognizes a bar code, it will exit the Blink mode. 2. Laser Off Power Save Mode: Turns the laser OFF after a configured period of non-use. The motor continues to spin allowing for a faster “wake” up time.
Beeper Options and Button Functions Changing the Beeper Tone Beeper tones may be configured incrementally using the following bar code. The new tone will be heard followed by a short pause. Two more new tones will be heard signifying the new setting has been stored in memory. The silent (no beep) tone is also selectable. N ³ 9 9 9 9 7 5 Changing the Beeper Volume Volume levels may be configured using the volume button or incrementally using the following bar code.
Startup When the scanner first receives power, the blue LED will turn on and the scanner will beep once. The scanner is now ready to scan. Power-Up Test Mode When a MS2420/MS2430 scanner is first powered up, it cycles through a number of self-tests before starting normal operation. If there are any initial failures during this sequence of tests the scanner will beep or razz to indicate the error and an error code will appear in the diagnostic indicator display.
46
Scale Operation Scale Zeroing After the unit has been officially calibrated (see page 48) the scale can be re-zeroed by pressing the scalezeroing button either on the unit or on the remote display stand. When the scale is at zero the amber LED will be illuminated. Figure 36. The scale zero button on scanner/scale. Figure 37. The scale zero indicator. Figure 38. The scale zero button on the optional remote display.
Calibration The scanner/Diva scale must be calibrated if: it is a first time installation the scale cannot be re-zeroed the calibration verification tests indicate errors there is a change in the units of measure [i.e. from pounds (lbs.
Priming the Scale for Calibration (lbs. or kg) Prime the scale before starting either method of calibration. Note: Calibrate the scanner/Diva scale after the unit is installed in the checkout countertop. It is important to use the correct certified (lb. or kg.) field weight set when calibrating the scale. 1. Check the platter to ensure that nothing is interfering with its freedom to move. Assure that no debris is present from daily use of the scanner/Diva scale if it has been in service. 2.
Scale Calibration Procedure (lbs. or kg) with Remote Display* 1. Temporarily remove the platter and place it in a safe location. Note: It is the responsibility of the owner of the scale to confirm compliance with the relevant Weights and Measures statutes and regulations applicable in your area by checking with the appropriate government agency before placing a newly calibrated unit into service or removing any official seals. 2.
Scale Calibration Procedure (lbs. or kg) with Remote Display* 4. Reinstall the platter onto the scanner/Diva scale. Figure 44. Install Platter 5. Go to Group 1 Step 8 (Weight Unit) of the Service Mode by pressing the Zero ( ) key several times until ‘Group 1 Step 8’ is displayed on the Remote Scale Display screen (see Figure 45 below). x Depending on the current Weight Unit setting, this value will either be 1, 2, 3, or 4. Figure 45. Remote Scale Display Group 1 Step 8 example shown 6.
Scale Calibration Procedure (lbs. or kg) with Remote Display* 7. Go to Group 2 Step 6 (Calibration) of the Service Mode. Press the Tare ( then use the Zero ( ) key to advance to step 6 of group 2. 8. Press the Tare ( ) key to change the prompt to ‘YES’. 9. Press the Zero ( ) key to accept. ) key to advance to Group 2, 10. The display will now show “- - - - - -“. This indicates the scale is ready to take a zero reading.
Bar Code Calibration Procedure without Remote Display* The following calibration procedure can be used when the remote scale display is not present. The MultiFunction Button (see page 44) is used to advance to the next stage of calibration and the LED display notifies the operator which ‘calibration stage’ is active. 1. Temporarily remove the platter and place it in a safe location.
Bar Code Calibration Procedure without Remote Display* 3. Enter the scale program mode. Press the calibration button to engage the scale calibration mode. If the system is a dual cable system, disconnect the host to scale RS232 cable from the unit. Figure 47. Entering the Scale Program Mode 4. Reinstall the platter onto the MS2420/MS2430 scanner/Diva scale (see Figure 48). Figure 48. Platter Installation 5. Enter bar code calibration mode.
Bar Code Calibration Procedure without Remote Display* Unit Calibration (Pounds) For Kilogram weight units see instructions on page 55. Pounds Calibration ³ 9 9 6 0 4 2 Figure 49. Entering Bar Code Calibration Mode (Pounds) Note: If a razz tone sounds, an error has occurred. Refer to Diagnostic Indicator Display; Error Codes starting on page 40 for additional information. Unit Calibration (Kilograms) For Pound weight, units see instructions on page 54.
Bar Code Calibration Procedure without Remote Display* 6. Make sure there is no load on the scale platter. The blue LED will be used to indicate the current step in the calibration process. 7. Calibrate a zero load. The blue LED will blink once periodically. Wait 8 to 10 seconds for scale stability, and then press the Multi-Function Button once. After the Multi-Function Button has been pressed, there will be a short delay followed by one short beep indicating that the zero load value has been stored.
Bar Code Calibration Procedure without Remote Display* 10. Calibration process is now complete. The scanner will automatically restart, and beep one time, in approximately 12 seconds. 11. Verify the calibration was successful with the calibrated weight. If the scale display does not accurately show the calibrated load weight correctly, restart this procedure from Step 1 on page 53. 12.
Calibration Verification U.S. Pounds (lbs.) The following tests verify if the scale's Calibration is accurate. For Kilograms see instructions starting on page 59. Note: • • • • The following tests are based on a 2-digit accuracy setting for pounds. Increasing Load Test Shift Test Decreasing Load Test Return to Zero Test Increasing Load Test 1. Ensure there is no load on the scale platter and verify the remote display reads 0.00 lbs. 2. Place a 5.00 lb.
Calibration Verification Kilograms (kg) The following tests verify if the scale's Calibration is accurate. For US Pounds see instructions starting on page 58. Note: The following tests are based on a 3-digit accuracy setting for kilograms. • Increasing Load Test • Shift Test • Decreasing Load Test • Return to Zero Test Increasing Load test 1. Ensure there is no load on the scale platter and verify the remote display reads 0.000 kg. 2. Place a 2.
Security Seal Installation Note: The certification of the weighing mechanism of the scale version of this scanner is subject to federal, state and local Weights and Measures statutes and regulations and can only be performed by authorized government agencies and/or their duly registered agents. Each time the scale or weighing mechanism is calibrated, it should be properly sealed with a paper seal or a wire seal prior to being placed into service in commerce.
Wire Security Seal (Seal Conversion Kit PN 46-00359)* 1. Temporarily remove the platter and place it in a safe location. 2. Install the calibration button sealing cover and through-hole sealing screw. 3. Tighten the screw and route the wire seal through the holes in the plate and screw. Figure 59. Calibration Switch/Button Wire Security Seal Assembly 4. Leaving the least amount of slack in the wire loop as possible, close the wire seal and verify the seal connection is secure. 5. Reinstall the platter.
62
Maintenance Horizontal Scan Window Replacement* Figure 61. Platter/Horizontal Scan Window Replacement * See replacement parts on page 4.
Daily Maintenance Smudges and dirt on the unit’s window can interfere with the unit’s performance. If the horizontal or vertical output windows require cleaning, use only a mild glass cleaner containing no ammonia. When cleaning the window, spray the cleaner onto a lint free, non-abrasive cleaning cloth then gently wipe the window clean. If the unit’s case requires cleaning, use a mild cleaning agent that does not contain strong oxidizing chemicals.
Troubleshooting The following guide is for reference purposes only. Contact a customer service representative to preserve the limited warranty terms. Symptom All Interfaces Possible Cause(s) Solution No LEDs, beep, or motor spin. No power is being supplied to the scanner. Check the transformer, outlet and the power strip. Make sure the power cable is plugged into the scanner. No LEDs and no beep. No power is being supplied to the scanner.
Symptom All Interfaces Possible Cause(s) Solution The unit scans a bar code, but locks up after the first scan (the blue LED stays on). The scanner is configured to support some form of host handshaking but is not receiving the signal. If the scanner is setup to support ACK/NAK, RTS/CTS, XON/XOFF, or D/E, verify that the host cable and host are supporting the handshaking properly. The unit scans but the data transmitted to the host is incorrect.
Symptom Possible Cause(s) Solution RS232 Only The unit powers up OK and scans OK but does not communicate properly to the host. The com port at the host is not working or is not configured properly. The cable is not connected to the proper com port. Check to make sure that the baud rate and parity of the scanner and the communication port match and the program is looking for RS232 data. The com port is not operating properly. The host is receiving data but the data does not look correct.
68
Scanner and Cable Terminations Scanner Pinout Connections The MS2420/MS2430 scanner terminates to 10-pin modular jacks located on the bottom of the unit. The serial number label indicates the model number and interface of the scanner. Pin 1 EAS Function EAS In Pin 1 DC Power Function No Connect 2 EAS Out 2 Earth Ground 3 No Connect 4 5.2VDC 5 Ground 6 12VDC Figure 62.
Scanner Scale Pinout Connections There are four additional 10-pin modular jacks located on the bottom of the of the MS2420/MS2430 scanner models that may be used for an integrated scale application and the use of a remote display. Note: Please keep in mind that every application is unique. The use of these connections depends on the specifications of the scale’s manufacturer. The following pinouts are for reference only.
Cable Connector Configurations RS232 Interface Cable, PN 57-57210x-N-3 Pin Function ** 1 No Connect 2 RS232 Transmit Output 3 RS232 Receive Input 4 DTR Input 5 Power/Signal Ground 6 DSR Output 7 CTS Input 8 RTS Output 9 No Connect 9-Pin D-Type Connector Full Speed USB Cable, PN 57-57201x-N-3 or PN 57-57227x-N-3 Pin Function** 1 PC +5V USB 2 D- 3 D+ 4 Ground Locking, Type A 57-57227x-N-3 Non-Locking, Type A 57-57201x-N-3 RS485 Cable, PN 57-57212x-N-3 Pin Function** 1 Signa
Cable Connector Configurations Aux Port Configuration Cable*, PN 57-57008x-N-3 Pin Function** 1 No Connect 2 Output from Scanner 3 Input to Scanner 4 No Connect 5 Ground 6-9 9-Pin D-Type Connector No Connect RS232 LSO/AUX Cable PN 57-57099x-3 or PN 57-57099x-3-12 Pin Function† 1 Signal Ground 2 RS232 from Aux / Secondary Scanner 3 RS232 to Aux / Secondary Scanner 4 RTS from Aux / Secondary Scanner 5 CTS to Aux / Secondary Scanner 6-8 No Connect 9 + 5VDC – Transformer / Direct
Regulatory Compliance Safety ITE Equipment IEC 60950-1, EN 60950-1 Laser Laser Class 1: IEC 60825-1:1993+A1+A2, EN 60825-1:1994+A1+A2 Caution Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure. Under no circumstances should the customer attempt to service the laser scanner. Never attempt to look at the laser beam, even if the scanner appears to be nonfunctional.
EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity CISPR 24, EN 55024 Note: Immunity performance is not guaranteed for scanner cables greater than 3 meters in length when fully extended. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Class A Devices The following is applicable when the scanner cable is greater in length than 3 meters (9.
Standard Europeo Attenzione Questo e’ un prodotto di classe A. Se usato in vicinanza di residenze private potrebbe causare interferenze radio che potrebbero richiedere all’utilizzatore opportune misure. Attention Ce produit est de classe “A”. Dans un environnement domestique, ce produit peut être la cause d’interférences radio. Dans ce cas l’utiliseteur peut être amené à predre les mesures adéquates.
76
Limited Warranty Honeywell International Inc. ("HII") warrants its products and optional accessories to be free from defects in materials and workmanship and to conform to HII’s published specifications applicable to the products purchased at the time of shipment.
78
Patents For patent information, please refer to www.honeywellaidc.com/patents.
80
Index A AC ............................................................ see power amber LED......................................... see indicators application............................................................ 40 audible ............................................... see indicators AUX ......................................................... 10, 67, 69 B beep ................................................... see indicators blue LED ............................................
power save .................................................... 43, 44 protocols .............................................................. 45 switch ..............................................................10, 31 cover ......................................................50, 53, 60 T R razzberry tone ................................................ 37, 39 regulatory compliance.................................... 72–75 remote display ....................................... 3, 4, 51, 59 repair...
Customer Support Technical Assistance If you need assistance installing or troubleshooting your device, please call your distributor or the nearest technical support office: North America/Canada Telephone: (800) 782-4263 E-mail: hsmnasupport@honeywell.com Latin America Telephone: (803) 835-8000 Telephone: (800) 782-4263 E-mail: hsmlasupport@honeywell.com Brazil Telephone: +55 (21) 3535-9100 Fax: +55 (21) 3535-9105 E-mail: brsuporte@honeywell.
Product Service and Repair Honeywell International Inc. provides service for all its products through service centers throughout the world. To obtain warranty or non-warranty service, contact the appropriate location below to obtain a Return Material Authorization number (RMA #) before returning the product. North America Telephone: (800) 782-4263 E-mail: hsmnaservice@honeywell.com Latin America Telephone: (803) 835-8000 Telephone: (800) 782-4263 Fax: (239) 263-9689 E-mail: laservice@honeywell.
Honeywell Scanning & Mobility 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywellaidc.