User manual

7–8
Host Scanner Commands
³ 1 1 8 0 1 5
Enable D/E Disable CommandThe scanner
will disable scanning after it receives an ASCII
“D” from the host device. It will enable scanning
when it receives an ASCII “E”.
³ 1 1 8 0 0 5
* Disable D/E Disable.
³ 1 1 8 2 1 1
Enable Z/R Type D/E SimulationThe scanner
will disable scanning after it receives an ASCII
“Z” from the host device. It will enable scanning
when it receives an ASCII “R”.
³ 1 1 8 2 0 1
* No Z/R Type D/E Simulation
³ 1 1 8 0 1 4
Enable F/L Laser CommandThe scanner will
turn off the laser after the scanner receives an
ASCII “F” character. The laser will turn on after it
receives an ASCII “L” character.
³ 1 1 8 0 0 4
* Disable F/L Laser Command
³ 1 1 8 1 1 5
Use DTR Scan DisableThe scanner will
monitor the DTR input to determine if scanning
should be allowed. A +12V active level enables
decoding. A -12V inactive level disables decoding.
³ 1 1 8 1 0 5
* Do Not Use DTR Scan DisableDo not monitor
the DTR input.
³ 1 1 8 1 1 0
Activate DC2 CharacterScanning will be
initiated with the receipt of a DC2 character
(^R, 124).
³ 1 1 8 1 0 0
* Do Not Activate on DC2 Character
³ 1 1 5 9 1 7
Transmit “METROLOGIC” with receipt of an
“I” (49H) via RS232
³ 1 1 5 9 0 7
* Don’t Transmit “METROLOGIC” with receipt
of an “I” (49H) via RS232