MS5100 Eclipse™ Series Installation and User’s Guide
Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of HII.
TABLE OF CONTENTS Introduction........................................................................................................... 1 Scanner and Accessories................................................................................. 2 Scanner Components....................................................................................... 4 Maintenance..................................................................................................... 4 Caution and Serial Number Labels..........
TABLE OF CONTENTS Regulatory Compliance Safety ............................................................................................................. 37 EMC ............................................................................................................... 38 Limited Warranty ................................................................................................ 40 Patents ............................................................................................................
INTRODUCTION The MS5145 Eclipse™ is a single-line, hand-held laser scanner. Equipped with Honeywell’s patented CodeGate® technology, Eclipse can be used in a wide variety of applications. CodeGate technology allows the user to easily target the desired bar code and complete the data transmission with a simple press of a button. This combination makes Eclipse a perfect selection for menu scanning, point-of-sale, document processing and inventory control.
INTRODUCTION Scanner and Accessories BASIC KIT Part # Description MS5145 Eclipse Scanner 00-02544 MetroSelect Single-Line Configuration Guide* 70-79016 MS5100 Eclipse Series Installation and User’s Guide* *Available for download from www.honeywell.com/aidc OPTIONAL ACCESSORIES Part # Description AC to DC Power Transformer- Regulated 5.2VDC @ 1A output.
INTRODUCTION Scanner and Accessories OPTIONAL ACCESSORIES Part # Description 55-55000x-3 RS232 PowerLink Cable with Built in Power Jack straight cord, long strain relief, black 55-55002x-3 Keyboard Wedge PowerLink Cable with Adapter straight cord, long strain relief, black 55-55020x-3 Stand Alone Keyboard PowerLink Cable, straight cord, long strain relief, black 55-55235x-N-3 USB Low Speed Communication Cable, Type A straight cord, long strain relief, black USB Full Speed Cable, Locking Plus-Power™
INTRODUCTION Scanner Components ITEM NO. DESCRIPTION 1 Mode Select Button/CodeGate Button (see page 12) 2 Red LED (see page 14) 3 Green LED (see page 14) 4 Pin Hole for Cable Release (see page 6) 5 Red Output Window (Laser Aperture) 6 Speaker (see page 13) 7 10-Pin RJ45, Female Socket (see page 33) Figure 1. Scanner Components Maintenance Smudges and dirt on the unit’s window can interfere with the unit’s performance.
INTRODUCTION Caution and Serial Number Labels Figure 2. Label Location on the Bottom of the Scanner with Example Caution To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN/IEC 60950-1. To maintain compliance with standard CSA C22.2 No. 60950-1/UL 60950-1 and norm EN/IEC 60950-1, the power source should meet applicable performance requirements for a limited power source.
INTRODUCTION Cable Removal Disconnect the power supply from the PowerLink cable and turn off power to the host system before removing the cable from the scanner. 1. 2. 3. 4. Locate the small ‘pin-hole’ on the front side of the scanner near the end of the handle. Bend an ordinary paperclip into the shape shown. Insert the paperclip (or other small metallic pin) into the small ‘pin-hole’. There will be a faint ‘click’ when the connector’s lock releases.
INSTALLATION RS232, Light Pen or Laser Emulation 1. Turn off the host system. 2. Plug the male, 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the MS5145. 3. Connect the 9-pin female end of the PowerLink cable to the appropriate communication port on the host device. 4. Plug the external power supply into the power jack on the PowerLink cable. Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet.
INSTALLATION RS485S 1. Turn off the host system. 2. Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the MS5145. 3. Connect the other end of the MVC cable to Port 9 of the host device. 4. Turn on the host device Figure 7. RS485S (above) Connections See page 5. S 8 ® Applicable for IBM Host applications.
INSTALLATION Keyboard Wedge 1. Turn off the host system. 2. Plug the male, 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the MS5145. 3. Disconnect the keyboard from the host/PC. 4. Connect the Y ends of the PowerLink cable to the keyboard and the host’s keyboard port. If necessary, use the supplied adapter cable to make the connections. 5. Plug the external power supply into the power jack on the PowerLink cable.
INSTALLATION Stand-Alone Keyboard 1. Turn off the host system. 2. Connect the 10-pin RJ45 male connector into the jack on the Eclipse. There will be a ‘click’ when the connection is made. If the scanner is receiving power from the host system, skip to step #5. 3. Connect the L-shaped plug of the power supply into the power jack on the PowerLink cable. Make sure the AC input requirements of the power supply match the AC outlet. Connect the power supply into an AC outlet.
INSTALLATION USB: Low Speed USB (-38) Full Speed USB (-40) 1. Turn off the host system. 2. Connect the 10-pin RJ45 male connector of the USB cable into the jack on the Eclipse. There will be a ‘click’ when the connection is made. 3. Connect the other end of the USB cable to the host USB port. 4. Turn on the host system. Figure 10. USB As a default, the MS5145-38 leaves the factory with USB Keyboard Emulation Mode enabled.
SCANNER OPERATION How to Use CodeGate and the Manual Activation Mode CODEGATE® MANUAL ACTIVATION MODE* * This feature is not a default setting. Refer to the MetroSelect Configuration Guide for instructions on enabling the Manual Activation Mode. Figure 11. CodeGate Enabled Figure 12.
SCANNER OPERATION Indicators Audible When the MS5145 scanner is operational, the scanner provides audible feedback to indicate the status of the scanner and the last scan. Eight settings are available for the tone of the beep (normal, six alternate tones and no tone). For instructions on how to change the tone of the beeper, refer to the Single-Line MetroSelect Configuration Guide. One Beep – On Power Up The green LED will turn on, then the red LED will flash and the scanner will beep once.
SCANNER OPERATION Indicators Visual The MS5145 is equipped with a red LED and green LED which indicate the scanner’s state and the status of the current scan when the unit is in operation. Figure 13. LED Color and Location Green and Red LEDs Are Off The LEDs will not be illuminated if the scanner is not receiving power from the host or transformer. Steady Green Indicates normal pulse or continuous laser operation. Accompanied by a razzberry tone, it indicates that an invalid bar code has been scanned.
SCANNER OPERATION Indicators Failure One Razzberry Tone – On Power Up This indicates the scanner has experienced a laser or flipper subsystem failure. Return the unit for repair to an Authorized Service Center. Continuous Razzberry Tone with no LEDs If, upon power up, the scanner emits a continuous razzberry tone, then the scanner has an experienced an electronic failure. Return the unit for repair to an Authorized Service Center.
SCANNER OPERATION Depth of Field vs. Minimum Bar Code Element Width Minimum Bar Code Element Width mm A .10 B .12 C .17 D .26 E .33 F .66 mils 4.1 4.8 6.8 10.4 13 26 Figure 14. Depth of Field vs.
SCANNER OPERATION Configuration Modes The MS5145 Eclipse has three modes of configuration. • Bar Codes The Eclipse can be configured by scanning the bar codes located in the MetroSelect® Single-Line Configuration Guide (MLPN 00-02544). This manual can be downloaded FREE at www.honeywell.com/aidc. • MetroSet®2 This user-friendly Windows-based configuration software allows the user to simply ‘point-and-click’ at the desired scanner options. This software can be downloaded FREE at www.honeywell.
SCANNER OPERATION 4. During configuration, the motor and laser turn off. YOU CANNOT SCAN A BAR CODE WHILE IN SERIAL CONFIGURATION MODE. 5. There is a 20 second window between commands. If a 20 second timeout occurs, the scanner will send a [nak] and you must start over. 6. To enter serial configuration mode, send the following command [stx]999999[etx]. 7. To exit serial configuration mode, send the following command [stx]999999[etx], the scanner will respond with an [ack] followed by 3 beeps. 8.
SCANNER OPERATION EXAMPLE #3: The following example shows the events that occur when an invalid bar code is sent. This sample will load the factory default settings and then set the baud rate to 19200.
TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a customer service representative (see page 44) to preserve the limited warranty terms. Symptoms Possible Causes Solution All Interfaces No power is being supplied to the unit. Check the transformer, the outlet and power strip. Make sure the cable is plugged into the unit. No power is being supplied to the unit from host. Some host systems cannot supply enough current to power Eclipse. A power supply may be needed.
TROUBLESHOOTING GUIDE Symptoms Possible Causes Solution The unit powers up, but does not scan and/or beep. The unit is trying to scan a particular symbology that is not enabled. UPC/EAN, Code 39, interleaved 2 of 5, Code 93, Code 128 and Codabar are enabled by default. Verify the type of bar code being read has been selected. The unit powers up, but does not scan and/or beep. The bar code being scanned does not satisfy the configured criteria for character length lock or minimum length.
TROUBLESHOOTING GUIDE Symptoms Possible Causes Solution The unit scans but the data is not correct. The unit’s configuration is not correct. Make sure that the proper PC type AT, PS2 or XT is selected. Verify the correct country code and data format is selected. Adjust the inter-character delay symptom. The unit is transmitting each character twice. The unit’s configuration is not correct. Increase the interscan code delay setting. Adjust whether the F0 break is transmitted.
RS232 DEMONSTRATION PROGRAM If an RS232 scanner is not communicating with your IBM compatible PC, key in the following BASIC program to test that the communication port and scanner are working. This program is for demonstration purposes only. It is only intended to prove that cabling is correct, the COM port is working, and the scanner is working. If the bar code data displays on the screen while using this program, it only demonstrates that the hardware interface and scanner are working.
DESIGN SPECIFICATIONS MS5145 Eclipse OPERATIONAL Light Source: Visible Laser Diode (VLD) @ 650 nm Laser Power: Less than 1.0 mW average Depth of Scan Field: Scan Speed: Scan Pattern: Minimum Bar Width: 0 mm – 140 mm (0" – 5.5") 0.33 mm (13 mil) Bar Code 72 ± 2 scan lines per second Single scan line 0.089 mm (3.5 mil) Decode Capability: Autodiscriminates all standard bar codes. For other code types, call a customer service representative.
DESIGN SPECIFICATIONS MS5145 Eclipse ELECTRICAL Input Voltage: 5VDC ± 0.25V Power: Operating 675 mW Current: Operating 135 mA average @ 5VDC DC Transformers: Class II; 5.2VDC @ 1A For regulatory compliance information, see pages 37 – 39.
APPLICATIONS AND PROTOCOLS The model number on each scanner includes the scanner number and factory default communications protocol. Scanner Version Identifier Communication Protocol(s) 00 Laser Emulation 11 RS485S RS232 - TXD, RXD, RTS, CTS 38 Low Speed USB, Serial Emulation or Keyboard Emulation 40 Full Speed USB 41 RS232/Light Pen Emulation 47 Keyboard Wedge 48 Keyboard Wedge, Stand-Alone Keyboard MS5145 S ® Applicable for IBM Host applications.
DEFAULT SETTINGS Many functions of the scanner can be configured or enabled/disabled. The scanner is shipped from the factory configured to a set of default conditions. All default parameters of the scanner have an asterisk ( * ) marked in the default column. If an asterisk is not in the default column then the default setting is off or disabled. Every interface does not support every parameter. A check mark ( ) will appear in the interface column if the interface supports the parameter listed.
DEFAULT SETTINGS Parameter Default ITF Symbol Lengths Variable Minimum Symbol Length Symbol Length Lock Bars High as Code 39 3 None * Spaces High as Code 39 Bars High as Scanned Spaces High as Scanned DTS/SIEMENS * DTS/NIXDORF NCR F NCR S Poll Light Pen Source Beeper Tone Normal Beep/Transmit Sequence Before transmit Communication Timeout None Razzberry Tone on Timeout Three Beeps on Timeout Same Symbol Rescan Timeout: 250 msecs Same Symbol Rescan Timeout: 375 msecs Same Symbol Rescan Timeout
DEFAULT SETTINGS Parameter Default RS232 Light Pen RS485S KBW USB Laser Emulation Infinite Same Symbol Timeout Inter-Character Delay Configurable In 1 msec steps (max 255 msecs) 1 msecs 10 msecs in KBW Number Of Scan Buffers (maximum) 4 Transmit UPC-A Check Digit * Transmit UPC-E Check Digit Expand UPC-E Convert UPC-A to EAN-13 Transmit Lead Zero On UPC-E Transmit UPC-A Number System * Transmit UPC-A Manufacturer ID# * Transmit UPC – A Item ID# * Transmit Codabar Start/Stop Characters CLS
DEFAULT SETTINGS Parameter Default RS232 Light Pen RS485S KBW USB Laser Emulation Transmit Sanyo ID Characters Nixdorf ID LRC Enabled UPC Prefix UPC Suffix Carriage Return * Line Feed-Disabled by Default in KBW * Tab Prefix Tab Suffix “DE” Disable Command “FL” Laser Enable Command DTR Handshaking support RTS/CTS Handshaking * Character Message RTS/CTS XON/XOFF Handshaking ACK/NAK as code 39 as code 39 as code 39 Two Digit Supplements Five Digit Supplements Bookland 977 (2 digit) Supplemental
DEFAULT SETTINGS Parameter Default 100 msec to Find Supplement Configurable in 100 msec Steps (max 800 msec) * RS232 Light Pen as code 39 Coupon Code 128 † Configurable Code Lengths 7 avail † Code Selects with Configurable Code Length Locks 3 avail Configurable Prefix Characters 10 avail Suffix Characters 10 avail RS485S KBW USB Laser Emulation as code 39 Prefixes for Individual Code Types Editing Inter Scan-Code Delay Configurable (100 µsec steps) 800 µsec Function/Control Key Support
UPGRADING THE FLASH ROM FIRMWARE The MS5145 is part of Honeywell’s line of scanners with flash upgradeable firmware. The upgrade process requires a new firmware file supplied to the customer by a customer service representative and MetroSet2 software . A personal computer running Windows 95 or greater with an available RS232 serial or USB port is required to complete the upgrade. PowerLink cable #54-54014 is required when using RS232 for the upgrade process.
SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections The MS5145 scanner interfaces terminate to a 10-pin modular jack. The serial number label indicates the interface enabled when the scanner is shipped from the factory. Figure 15.
SCANNER AND CABLE TERMINATIONS Figure 16.
SCANNER AND CABLE TERMINATIONS Cable Connector Configurations RS232 PowerLink Cable, 55-55000x-3 Pin Function 1 Shield Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 DTR Input/Light Pen Source 5 Power/Signal Ground 6 Light Pen Data (DSR Out for -14 interfaces) 7 CTS Input 8 RTS Output 9 +5VDC 9-Pin D-Type Connector Stand Alone Keyboard PowerLink Cable, 55-55020x-3 Pin 1 2 3 4 5 6 Function PC Data NC Power Ground +5VDC PC Power to KB PC Clock NC 6-Pin Male Mini-DIN Connector
SCANNER AND CABLE TERMINATIONS Cable Connector Configuration Keyboard Wedge PowerLink Cable 55-55002A-3 Pin 1 2 3 4 5 Pin 1 2 3 4 5 6 Function Keyboard Clock Keyboard Data No Connect Power Ground +5 Volts DC Function PC Data No Connect Power Ground +5 Volts DC PC Clock No Connect 5-Pin DIN, Female 6-Pin DIN, Male An adapter cable with a 5-pin DIN male connector on one end and a 6-pin mini DIN female connector on the other will be supplied.
REGULATORY COMPLIANCE Safety ITE Equipment IEC 60950-1, EN 60950-1 Laser Laser Class 1: IEC 60825-1:1993+A1+A2, EN 60825-1:1994+A1+A2 Caution Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure. Under no circumstances should the customer attempt to service the laser scanner. Never attempt to look at the laser beam, even if the scanner appears to be nonfunctional.
REGULATORY COMPLIANCE EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity CISPR 24, EN 55024 NOTE: Immunity performance is not guaranteed for scanner cables greater than 3 meters in length when fully extended. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Class A Devices The following is applicable when the scanner cable is greater in length than 3 meters (9.
REGULATORY COMPLIANCE EMC Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Standard Europeo Attenzione Questo e’ un prodotto di classe A. Se usato in vicinanza di residenze private potrebbe causare interferenze radio che potrebbero richiedere all’utilizzatore opportune misure. Attention Ce produit est de classe “A”. Dans un environnement domestique, ce produit peut être la cause d’interférences radio.
LIMITED WARRANTY Honeywell International Inc. ("HII") warrants its products and optional accessories (“Accessories”) to be free from defects in materials and workmanship and to conform to HII’s published specifications applicable to the products purchased at the time of shipment.
PATENTS This Honeywell product may be covered by, but not limited to, one or more of the following US Patents: U.S. Patent No.
INDEX A AC .................................. see power accessories ...............................2, 3 aperture .........................................4 B beeper .........................see indicator button ......................................4, 12 Button ..........................................32 C cable.................... 20–21, 36, 33–36 communication.. 2, 3, 6, 7–11, 22, 27 MVC...........................................3 PowerLink ...... 6, 7–11, 36, 33–36 USB ..................................
INDEX S U safety.....................................37, 39 stand .............................................3 Stand-Alone Keyboard see interface USB ............................see interface V T VLD............................................. 24 terminations...........................33–36 tone .........................................1, 13 transformer ..................... see power troubleshooting......................20–21 W warranty ...................................... 40 window............
CONTACT INFORMATION The Americas (TA) Germany USA Tel: 49-89-89019-0 Fax: 49-89-89019-200 Email: info@de.metrologic.com Tel: 866.460.8033 (Customer Service) 888.633.3762 (Technical Support) 856.228.8100 (Corporate) Fax: 856.228.6673 (Sales) 856.228.1879 (Marketing) 856.228.0653 (Legal/Finance) Italy Tel: +39 0 51 6511978 Fax: +39 0 51 6521337 Email: info@it.metrologic.com Brazil Poland Tel: 55.11.5185.8222 Fax: 55.11.5185.8225 Email: info@br.metrologic.
PRODUCT SERVICE AND REPAIR North America Tel: 866.460.8033 Fax: 856.228.6673 (Sales) Email: info@metrologic.com Suzhou Sales Office Tel: 86-512-67622550 Fax: 86-512-67622560 Email: info@cn.metrologic.
January 2009 70 - 79016E