6 - 29
Default = Don’t Require 5 Digit Addenda.
EAN-13 Beginning with 979 Addenda Required
These settings program the scanner to require a 5 digit addenda only on EAN-13 bar codes that begin with “979.” The fol-
lowing settings can be programmed:
Require 5 Digit Addenda: All EAN-13 bar codes that begin with “979” must have a 5 digit addendum. The EAN-13 bar
code with the 5 digit addendum is then transmitted as a single, concatenated bar code. If a 5 digit addendum is not found
within the Addenda Timeout period, the EAN-13 bar code is discarded.
Don’t Require 5 Digit Addenda: If you have selected Require 5 Digit Addenda, and you want to disable this feature,
scan Don’t Require 5 Digit Addenda. EAN-13 bar codes are transmitted, depending on the setting you are using for EAN/
JAN-13 Addenda Required.
Default = Don’t Require 5 Digit Addenda.
Addenda Timeout
You can set a time during which the scanner looks for an addenda. If an addenda is not found within this time period, the
data can be either transmitted or discarded, based on the setting you are using for EAN/JAN-13 Addenda Required. Set
the length (in milliseconds) for this timeout by scanning the bar code below, then setting the timeout (from 0-65535 millisec-
onds) by scanning digits from the Programming Chart, then scanning Save. Default = 100.
Note: The Addenda Timeout setting is applied to all addenda and coupon code searches.
* Don’t Require 5 Digit Addenda
Require 5 Digit Addenda
* Don’t Require 5 Digit Addenda
Require 5 Digit Addenda
Addenda Timeout