User manual

3 - 18
Scan Discard Partial Sequence to discard partial sequences when the output sequence operation is terminated before
completion. Scan Transmit Partial Sequence to transmit partial sequences. (Any fields in the sequence where no data
match occurred will be skipped in the output.)
Require Output Sequence
When an output sequence is Required, all output data must conform to an edited sequence or the scanner will not transmit
the output data to the host device. When it’s On/Not Required, the scanner will attempt to get the output data to conform
to an edited sequence but, if it cannot, the scanner transmits all output data to the host device as is.
When the output sequence is Off, the bar code data is output to the host as the scanner decodes it. Default = Off.
Note: This selection is unavailable when the Multiple Symbols Selection is turned on.
Multiple Symbols
When this programming selection is turned On, it allows you to read multiple symbols with a single pull of the scanner’s trigger.
If you press and hold the trigger, aiming the scanner at a series of symbols, it reads unique symbols once, beeping (if turned on)
for each read. The scanner attempts to find and decode new symbols as long as the trigger is pulled. When this programming
selection is turned Off, the scanner will only read the symbol closest to the aiming beam. Default = Off.
Transmit Partial Sequence
* Discard Partial Sequence
Required
On/Not Required
*Off
On
* Off