METROLOGIC INSTRUMENTS, INC.
Copyright © 2008 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976. Trademarks Metrologic is a registered trademark of Metrologic Instruments, Inc. Products identified in this document are hereby acknowledged as trademarks, registered or otherwise, of Metrologic Instruments, Inc.
TABLE OF CONTENTS Introduction Product Overview ............................................................................................. 1 Scanner and Accessories................................................................................. 2 Scanner Components....................................................................................... 4 The PowerLink Cable Disconnecting............................................................................................... 5 Connecting ...........
TABLE OF CONTENTS IR Activation Range............................................................................................ 25 Applications and Protocols ................................................................................. 26 Troubleshooting Guide ....................................................................................... 27 RS232 Demonstration Program ......................................................................... 30 Design Specifications Operational................
INTRODUCTION Product Overview Metrologic's MS9500 Voyager® series of hand-held (single-line) laser scanners offers the user an aggressive solution for scanning all standard 1D bar codes including GS1 DataBar™ (RSS) bar codes. The MS9500 series is equipped with both in-stand and out-of-stand operation enabling hand-held or fixed projection scanning. The MS9520 Voyager model includes all of the same features as the MS9540 VoyagerCG model, with the exception of Metrologic’s patented CodeGate® technology.
INTRODUCTION Scanner and Accessories BASIC KIT Part # Description MS9520 or MS9540 Voyager Bar Code Scanner or VoyagerCG Bar Code Scanner with CodeGate 00-02544 MetroSelect Single-Line Configuration Guide* 00-02410 MS9500 Voyager Series Single-Line Hand Held Laser Scanner Installation and User’s Guide* * Available for download on the Metrologic website - www.metrologic.com OPTIONAL ACCESSORIES Part # Description AC to DC Power Transformer - Regulated 5.2VDC @ 1A output.
INTRODUCTION Scanner and Accessories OPTIONAL ACCESSORIES Part # Description USB Full Speed Cable Locking Plus-Power™ Type A, Black, Coiled Cord with Long Strain Relief 53-53213x-N-3 USB Full Speed Cable Locking Plus-Power™ Type A, Black, Coiled Cord with Long Strain Relief, Extended Length 53-53214x-N-3 Not for use with Low Speed USB scanners. Use with Full Speed USB scanners only.
INTRODUCTION Scanner Components No. Item Description ♦ 1 Green LED 2 Red LED 3 Yellow LED ♦ See Visual Indicators on page 18 See Visual Indicators on page 18 ♦♦ ♦♦ See Visual Indicators on page 18 4 Button See How to use CodeGate on page 12 5 Red Window Laser Aperture 6 Speaker See Audible Indicators on page 17 7 Cable Release Pin-Hole See The PowerLink Cable on page 5 8 Cable Connection 10-pin RJ45, Female Socket, See Scanner Pinout Connections on page 38 Figure 1.
INTRODUCTION Disconnecting the PowerLink Cable Before removing the cable from the scanner, Metrologic recommends that the power on the host system is off and the power supply has been disconnected from the PowerLink cable. Figure 2. 1. Locate the small ‘pin-hole’ on the top of the unit near the bottom of the Voyager logo. 2. Bend an ordinary paperclip into the shape shown above. 3. Insert the paperclip (or other small metallic pin) into the small ‘pin-hole’. 4.
INTRODUCTION Labels Every scanner has labels and molded text located on the underside of the unit. The labels and text contain important information such as the unit’s date of manufacture, serial number, CE and caution information. Figure 5 provides examples of the labels and the molded text. Figure 5 .
INSTALLING THE SCANNER TO THE HOST SYSTEM RS232, Laser Emulation, and Light Pen Emulation 1. Turn off the host system. 2. Connect the 10-pin RJ45 male connector into the jack on the scanner. There will be an audible click when the connector lock engages. If the scanner is receiving power from the host system, skip to step #5. 3. Connect the L-shaped plug of the power supply into the power jack on the PowerLink cable. 4. Verify the AC input requirements of the power supply match the AC outlet.
INSTALLING THE SCANNER TO THE HOST SYSTEM RS485 1. Turn off the host system. 2. Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the scanner. You will hear a ‘click’ when the connection is made. 3. Connect the other end of the MVC cable to the host device. 4. Turn on the host system. Figure 7. Plugging the scanner into a port on the host system does not guarantee that scanned information will be communicated properly to the host system.
INSTALLING THE SCANNER TO THE HOST SYSTEM Keyboard Wedge 1. Turn off the host system. 2. Connect the 10-pin RJ45 male connector into the jack on the scanner. You will hear a ‘click’ when the connection is made. If the scanner is receiving power from the host system, skip to step #5. 3. Connect the L-shaped plug of the power supply into the power jack on the PowerLink cable. 4. Verify the AC input requirements of the power supply match the AC outlet. Connect the power supply into an AC outlet.
INSTALLING THE SCANNER TO THE HOST SYSTEM Stand-Alone Keyboard 1. Turn off the host system. 2. Connect the 10-pin RJ45 male connector into the jack on the scanner. You will hear a ‘click’ when the connection is made. If the scanner is receiving power from the host system, skip to step #5. 3. Connect the L-shaped plug of the power supply into the power jack on the PowerLink cable. 4. Verify the AC input requirements of the power supply match the AC outlet. Connect the power supply into an AC outlet.
INSTALLING THE SCANNER TO THE HOST SYSTEM Integrated USB: Full Speed (-40) Low Speed (-38) 1. Turn off the host system. 2. Connect the 10-pin RJ45 male connector of the USB cable into the jack on the scanner. You will hear a ‘click’ when the connection is made. 3. Connect the other end of the USB cable to the host USB port. 4. Turn on the host system. Figure 10. As a default, the MS95x0-38 leaves the factory with USB Keyboard Emulation Mode enabled.
THE MS9540 VOYAGERCG® SERIES How to Use CodeGate and the Manual Activation Mode CODEGATE® MANUAL ACTIVATION MODE* * This feature is not a default setting. Refer to the MetroSelect Configuration Guide for instructions on enabling the Manual Activation Mode. Figure 11. Figure 12.
STAND KITS Types c. Free Standing Kit #46-46128 (Figure 13) a. Kit Contains: a. Stand........................................................... Qty. 1 b. Apron........................................................... Qty. 1 c. Screw, M3 x 6 mm ...................................... Qty. 2 d. Washer, #5 x .5 OD..................................... Qty. 2 e. Stand Anchor .............................................. Qty. 1 f. M3 x 20 mm Set Screw ............................... Qty. 1 d. b. e. f.
STAND KITS Assembly There are two options for assembling the stand. The first option is a selfsupporting stand that can be moved freely about on the countertop. The second option is used if the stand will be bolted or hard-mounted to the countertop. Stand Option 1: Self-Supported Stand Kit #46-46128 Apron Step 1 Slide the apron over the stand. Stand Figure 17. Step 2 Apron Position the stand so that it sits under the tab on the apron.
STAND KITS Assembly Stand Option 2: Hard-Mount Kits #46-46128 and #46-46351 Anchor from Kit #46-46128 Base Assembly from Kit #46-46351 or MS951 Stand Base Step 3 Screw the stand anchor onto the base assembly until it sits flush. Figure 21. Step 4 Remove the logo plate on the stand by gently using an exacto knife to release the plate hook. Figure 22. Step 5 Position the stand over the base assembly. Figure 23.
STAND KITS Assembly Wall Mount, Option 1: For Kit #46-46508 Step 1 Drill two #39 pilot holes 3.00″ apart. Step 2 Attach the Wall Mount Hanger to the wall with the two #8 wood screws provided. Figure 26. Wall Mount, Option 2: Kit #46-46508 Step 1 Attach the Wall Mount Base to the Wall Mount Hanger with the two 4.8 x 13 mm self-tapping screws. Step 2 Remove one side of the protective backing from the double-sided adhesive tape. Figure 27. Step 3 Attach the tape to the back of the Wall Mount Hanger as shown.
INDICATORS Audible When the Voyager is in operation, it provides audible feedback. These sounds indicate the status of the scanner. Eight settings are available for the tone of the beep (normal, 6 alternate tones and no tone). To change the beeper tone, refer to the MetroSelect Single-Line Configuration Guide or MetroSet2’s help files. One Beep When the scanner first receives power, the green* LED will turn on, the red* LED will flash, and the scanner will beep once. The scanner is ready to scan.
INDICATORS Visual Figure 29. LED Configuration The MS9540 has three LED indicators located on the head of the scanner. The MS9520 has two LED indicators located on the head of the scanner. When the scanner is in operation, the flashing, or stationary activity of the LEDs indicates the status of the scanner and the current scan. All LEDs are Off The LEDs will not be illuminated if the scanner is not receiving power from the host or transformer. The scanner is in stand-by mode, and CodeGate is enabled.
INDICATORS Failure Modes Razzberry Tone – On Start-Up This indicates the scanner has experienced a flipper/motor failure. Return the unit for repair to an authorized service center. Continuous Razzberry Tone with all LEDs Off If, upon power, the scanner emits a continuous razzberry tone, then the scanner has an experienced an electronic failure. Return the unit for repair to an authorized service center.
CONFIGURATION MODES The MS9500 Voyager has three modes of configuration. • Bar Codes Voyager or VoyagerCG can be configured by scanning the bar codes located in the MetroSelect® Single-Line Configuration Guide (MLPN 00-02544). This manual can be downloaded for FREE at www.metrologic.com. • MetroSet®2 This user-friendly Windows-based configuration software allows you to simply ‘point-and-click’ at the desired scanner options. This software can be downloaded for FREE at www.metrologic.
CONFIGURATION MODES 4. During configuration, the motor and laser turn off. YOU CANNOT SCAN A BAR CODE WHILE IN SERIAL CONFIGURATION MODE. 5. There is a 20 second window between commands. If a 20 second timeout occurs, the scanner will send a [nak] and you must start over. 6. To enter serial configuration mode, send the following command [stx]999999[etx]. 7. To exit serial configuration mode, send the following command [stx]999999[etx], the scanner will respond with an [ack] followed by 3 beeps. 8.
CONFIGURATION MODES EXAMPLE #3: The following example shows the events that occur when an invalid bar code is sent. This sample will load the factory default settings and then set the baud rate to 19200.
UPGRADING THE FIRMWARE The Voyager series is part of Metrologic's line of scanners with flash upgradeable firmware. The upgrade process requires a new firmware file supplied to the customer by a customer service representative and Metrologic's MetroSet2 software . A personal computer running Windows 95 or greater with an available RS232 serial or USB port is required to complete the upgrade. Do not use the standard cable supplied with Keyboard Wedge or RS485 interface kits for firmware upgrades.
DEPTH OF FIELD MINIMUM BAR CODE ELEMENT WIDTH A B C D E F G H J K mm .13 .15 - - .19 - .25 .33 .53 - mils 5.2 5.7 - - 7.5 - 10 13 21 - Figure 30.
IR ACTIVATION RANGE The scanner's laser will turn off if the scanner has been idle. When the scanner's IR detects movement in the activation area (see figure below), the laser will automatically turn on, preparing the scanner for bar code recognition, decoding, and transmission. The default laser/scan mode for the MS9500 series is normal scan. Figure 31.
APPLICATIONS AND PROTOCOLS The model number on each scanner includes the scanner number and factory default communication protocol.
TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-Metro or 1-800-436-3876 to preserve the limited warranty terms. Symptoms Possible Causes Solution All Interfaces No power is being supplied to the unit. The unit has no LEDs, beep or laser. No power is being supplied to the unit from host. Check the transformer, the outlet and power strip. Make sure the cable is plugged into the unit.
TROUBLESHOOTING GUIDE Symptoms Possible Causes The unit powers up, but does not scan and/or beep. The bar code being scanned does not satisfy the configured criteria for character length lock or minimum length. Solution Verify that the bar code being scanned falls into the configured criteria. The scanner defaults to a minimum of 3 character bar code. The following item is only relevant for RS232 and Serial Emulation USB interfaces.
TROUBLESHOOTING GUIDE Symptoms Possible Causes Solution The following four items are relevant for a Keyboard Wedge interface only. The unit scans but the data is not correct. The unit’s configuration is not correct. Make sure that the proper PC type AT, PS2 or XT is selected. Verify the correct country code and data format is selected. Adjust the intercharacter delay symptom. The unit is transmitting each character twice. The unit’s configuration is not correct.
RS232 DEMONSTRATION PROGRAM If an RS232 scanner is not communicating with an IBM compatible PC, key in the following BASIC program to test that the communication port and scanner are working. This program is for demonstration purposes only. It is only intended to prove that cabling is correct, the COM port is working, and the scanner is working. If the bar code data displays on the screen while using this program, the hardware interface and scanner are working.
DESIGN SPECIFICATIONS MS9500 Series Specifications OPERATIONAL Light Source Visible Laser Diode 650 nm Laser Power: Less than 1 mW (peak) Depth of Scan Field: Scan Speed: Scan Pattern: Minimum Bar Width: Infrared Activation: 0 mm - 203 mm (0" - 8") for 0.330 mm (13 mil) bar code at default settings 72 scan lines per second Single scan line 0.127 mm (5.
DESIGN SPECIFICATIONS MS9500 Series Specifications MECHANICAL Length: 198 mm (7.8") Width: Handle - 45 mm (1.8"), Head - 78 mm (3.1") Depth: 40 mm (1.6") Weight: 149 g (5.25 oz) ELECTRICAL Input Voltage: 5VDC ± 0.25V Operating = 0.825 W typical Power: Standby = 0.600 W typical Operating = 165 mA @ 5VDC typical Current: Standby = 120 mA @ 5VDC typical DC Transformers: Class 2; 5.2V @ 1A For regulatory compliance information see pages 43 – 45.
DEFAULT SETTINGS Many functions of the scanner can be configured or enabled/disabled. The scanner is shipped from the factory configured to a set of default conditions. All default parameters of the scanner have an asterisk ( * ) marked in the default column. If an asterisk is not in the default column then the default setting is off or disabled. Not every interface supports every parameter. A check mark ( ) will appear in the interface column if it supports the parameter listed.
DEFAULT SETTINGS Parameter Default Mod 43 Check on Code 39 MSI-Plessy 10/10 Check Digit MSI-Plessy Mod 10 Check Digit * Paraf Support ITF ITF Symbol Lengths Minimum Symbol Length Symbol Length Lock Bars High as Code 39 Variable 3 None * Spaces High as Code 39 Bars High as Scanned Spaces High as Scanned DTS/SIEMENS DTS/NIXDORF * NCR F NCR S Poll light pen source Beeper tone Normal Beep Transmit Sequence Before transmit Communication Timeout None Razzberry Tone on Timeout Three Beeps on Timeout
DEFAULT SETTINGS Parameter Default RS232 Light RS485 KBW USB Pen Laser Emulation Same symbol rescan timeout: 750 msecs Same symbol rescan timeout: 875 msecs * Same symbol rescan timeout: 1000 msecs No Same symbol timeout Infinite Same symbol timeout Inter-character delay Configurable in 1 msec steps (max 255 msecs) 1 msecs 10 msecs in KBW Number of scan buffers (maximum) 4 Transmit UPC-A check digit * Transmit UPC-E check digit Expand UPC-E Convert UPC-A to EAN-13 Transmit lead zero on UPC-E Tr
DEFAULT SETTINGS Parameter Default RS232 Light RS485 KBW Pen USB Laser Emulation Transmit Sanyo ID Characters Nixdorf ID LRC Enabled UPC Prefix UPC Suffix Carriage Return * Line Feed-Disabled by default in KBW * Tab Prefix Tab Suffix “DE” Disable Command “FL” Laser Enable Command DTR Handshaking support RTS/CTS Handshaking Character * Message RTS/CTS XON/XOFF Handshaking ACK/NAK as code 39 as code 39 as code 39 Two Digit Supplements Five Digit Supplements Bookland 977 (2 digit) Supplemental Req
DEFAULT SETTINGS Parameter 100 msec to Find Supplement Configurable in 100 msec steps (max 800 msec) Default RS232 Light RS485 KBW Pen USB Laser Emulation * as code 39 Coupon Code 128 † Configurable Code Lengths 7 avail † Code Selects with configurable Code Length Locks 3 avail Configurable Prefix characters 10 avail Suffix characters 10 avail as code 39 Prefixes for Individual Code types Editing Inter Scan-Code delay configurable (100 µsec steps) 800 µsec Function/control Key Support Mi
SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections The MS9520 and MS9540 scanner interfaces terminate to a 10-pin modular jack. The serial # label indicates the interface enabled when the scanner is shipped from the factory.
SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections MS95x0-00 Laser Emulation Pin 1 2 3 4 5 6 7 8 9 10 Function Ground RS232 Transmit Output RS232 Receive Input Flip Sense/Start of Scan Output Proximity Detect/Trigger Emulation Output Scan/Laser Enable Input Reserved Data Out +5VDC Shield Ground MS95x0-14 RS232 Pin 1 2 3 4 5 6 7 8 9 10 Function Ground RS232 Transmit Output RS232 Receive Input RTS Output CTS Input DTR Input Reserved DSR Out +5VDC Shield Ground MS95x0-40 Full Speed USB & MS95x0-38 L
SCANNER AND CABLE TERMINATIONS Cable Connector Configuration (Host End) RS232 PowerLink Cable MLPN 53-53000x-3 Pin Function 1 Shield Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 DTR Input/Light Pen Source 5 Signal Ground 6 Light Pen Data (DSR Out for -14 interfaces) 7 CTS Input 8 RTS Output 9 +5VDC 9-Pin Female, D-Type USB Cables 53-53213x-N-3, 53-53214x-N-3 or 53-53235x-N-3 Pin Function MLPN 1 PC +5V/V_USB 2 D- 3 D+ 4 Ground Locking Type A Non-Locking Type A Shiel
SCANNER AND CABLE TERMINATIONS Cable Connector Configuration (Host End) Keyboard Wedge PowerLink Cable MLPN 53-53002x-3 Pin 1 2 3 4 5 Pin 1 2 3 4 5 6 Function Keyboard Clock Keyboard Data No Connect Power Ground +5 Volts DC Function PC Data No Connect Power Ground +5 Volts DC PC Clock No Connect 5-Pin DIN, Female 6-Pin DIN, Male Metrologic will supply an adapter cable with a 5-pin DIN male connector on one end and a 6-pin mini DIN female connector on the other.
LIMITED WARRANTY The MS9500 Voyager and VoyagerCG series scanners are manufactured by Metrologic at its Suzhou China facility. The MS9500 Voyager and VoyagerCG series scanners have a five (5) year limited warranty from the date of manufacture. Metrologic warrants and represents that all MS9500 Voyager and VoyagerCG series scanners are free of all defects in material, workmanship and design, and have been produced and labeled in compliance with all applicable U.S.
REGULATORY COMPLIANCE Safety ITE Equipment IEC 60950-1, EN 60950-1 Laser Laser Class 1: IEC 60825-1:1993+A1+A2, EN 60825-1:1994+A1+A2 Caution Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure. Under no circumstances should the customer attempt to service the laser scanner. Never attempt to look at the laser beam, even if the scanner appears to be nonfunctional.
REGULATORY COMPLIANCE EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity CISPR 24, EN 55024 Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Class A Devices The following is applicable when the scanner cable is greater in length than 3 meters (9.8 feet) when fully extended: Les instructions ci-dessous s’appliquent aux cables de scanner dépassant 3 métres (9.
REGULATORY COMPLIANCE EMC Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Class B Devices The following is applicable when the scanner cable is less than 3 meters (9.8 feet) in length when fully extended: Les instructions ci-dessous s’appliquent aux cables de scanner ne dépassant pas 3 métres (9.
PATENTS This METROLOGIC product may be covered by, but not limited to, one or more of the following US Patents: US Patent No.
INDEX A I AC .................................. see power accessories ...............................2, 3 adapter ..........................................2 IBM ................see interface: RS485 immunity...................................... 44 indicator audible............................... 21, 31 failure ................................ 27–29 visual ....................... 4, 27–29, 31 interface .......................... 31, 38–41 Keyboard Wedge 1, 9, 26, 33–37, 38, 41 Laser Emulation .
INDEX P parameter ..............................33–37 pin assignments .............. see cable power ...................... 2, 7–11, 27, 32 PowerLink...................41, see cable protocols..................... see interface specifications ........................ 31, 32 stand ................................. 3, 13–16 T termination ............................ 38–41 troubleshooting ..................... 27–29 R U razzberry tone .............see indicator Red LED......................
49
April 2008 Printed in China 00 - 02410K
January 2008, Version 03 Printed in the USA 00 - 02410 J