Water Heater User Manual
``
PDX SERVICE PROCEDURE III
Pressure Switch Testing and 
Replacement
Pressure Switch Testing
WARNING
120 volt potential exposure. Use caution
making voltage checks to avoid personal injury.
Step 1. Position power switch on gas control
to the “OFF” position.
Step 2. Remove the three screws (Phillips screw driver) from control access cover on blower assembly and 
remove cover (see photo 1).
Step 3. Carefully remove pressure switch from blower housing (see photo 2)
2
Use a multi-meter set to the 
ohms setting. With blower off, 
check across pressure
switch terminals.
Are switch contacts open?
(no electrical continuity)
Check tubing and pressure tap 
on switch for blockage.
Is there blockage?
Replace switch
(see page 18)
Position gas valve power 
switch to the “ON” position 
and adjust thermostat
to call for heat,
this will start the blower.
Check with multi-meter, do 
pressure switch contacts close 
with blower running with the 
switch in the vertical 
postition?
With steps 1,2 & 3 complete,
disconnect wire leads from 
pressure switch. 
Y
N
Y
N
Switch contacts are OK.
See safety circuit trace
(page 30)
Is vent 
system
blocked
N
See blower testing 
(page 21)
Is blower OK?
Clear blockage
Y
N
Y
N
Correct blower 
problem.
Pressure Switch
Slide pressure switch in direction of 
arrow while tilting slightly away 
from blower housing.
Is vent system length 
within vent table 
specifications
listed on page 7 or 8
Y
Reconfigure vent 
system to be 
compliant with
vent tables.
N
Y
Pressure switch 
wire leads
Page 18
Check tubing and 
pressure tap on 
switch for blockage.
Is there blockage?
N
Y
PDX Series
1
Exhaust pressure 
switch
3
18