Water Heater User Manual
PDX SERVICE PROCEDURE V
Blower Temperature Switch Testing 
and Replacement
Blower Temperature Switch 
Replacement.
WARNING
120 volt potential exposure. Use caution
to avoid personal injury.
Step 1. Position gas control power switch to the “OFF” position 
and unplug heater from wall outlet.
Step 2. Remove the three screws (Phillips screw driver) from the 
control access cover on blower and remove cover.
(see photo 17)
17
Step 3. Locate blower temperature switch (see photo 18)
Step 4. Disconnect red and yellow wire leads from switch.
Step 5. With an appropriate tool such as side cutters, snip the 
retaining lug from the blower housing to allow removal of 
temperature switch (see photo 19).
Step 6. Remove switch from blower housing.
Step 7. Install new switch. Be sure switch is properly seated in 
mounting area. 
Step 8. Reconnect red and yellows wires to new switch. Wires are 
interchangeable with either terminal.
Step 9. Position gas control power switch to the “ON” position 
and verify proper heater operation.
Step 10. Replace control access cover from step 2.
Blower temperature 
switch location
18
Snip retaining lug 
from blower housing
19
Page 23
PDX Series
23