User Manual

Table Of Contents
40 PM45 and PM45c Accessory User Guide
5. Click Save. The settings are saved.
Setup Mode
Use the printer touch screen to view and change settings.
1. Press Menu > Settings > System Settings > Manage I/O.
2. Choose Enable from the drop-down list for the applicator.
3. From the menu, select Menu > Settings > Printing > Applicator.
About Applicator Input Signals
This section describes the INPUT signals.
Note: All IN signals are asserted low and de-asserted high.
About Applicator OUT Signals
This section describes the Applicator OUT signals.
Note: Unless described otherwise, all OUT signals are asserted low and de-asserted high.
DC 24V Configures the printer to use either its internal power
supply or an external supply (connected to the External
Power port) to provide +24VDC to the Z-Style and S-
Style ports.
Setting Description
Signal Description
Startprint Starts a print job. Choose either Level or Pulse.
Level: The printer starts printing labels when the startprint signal is asserted
and continues printing until the signal is de-asserted.
Pulse: The printer prints one label when the startprint signal is asserted. The
startprint signal must be de-asserted and then asserted to print the next label.
Feed Feeds a single label. Not supported by S-Style.
Pause Toggles between Pause mode and printing. Not supported by S-Style.
Reprint Reprints the last valid label.
Apperr1 Applicator error 1.
Apperr2 Applicator error 2.
Apperr3 Applicator error 3.
RTWINEXT External input signal, which you can use to monitor the operational status of
the entire system.
Signal Description
Data Ready Asserted when the printer is ready to receive a startprint signal and
execute the current print job. De-asserted when the print cycle ends. Not
supported by S-Style.