Competitive Cross Reference

THE FIRING LINE HONEYWELL FLAME SENSORS (SCANNERS) CROSS REFERENCE
15 70-8317—01
Table 17. FIREYE
ULTRAVIOLET FLAME DETECTOR CROSS REFERENCE.
a
The output of this sensor is not compatible with competitive amplifiers/primary relays. Programmer and amplifier or relay must also be replaced with appropriate Honey-
well control. Refer to FIRING LINE Primary and Programmer Cross References and Modernization section.
b
Current replacement has ambient temperature rating of 0° to 215° F. If -40° F rating is required, order C7027A1031. Heat Block (part no. 136733) and 1/2 x 3/8 Bushing
(part no. 390427B) must be ordered separately, if needed.
c
Current replacement has 1/2 NPT mounting. Use standard 3/4 x 1/2 reducer coupling.
d
Replacement suggestion is a straight body.
Device to be
Replaced
Current
Replacement
a
Specifications of Device to be Replaced
Comments
Mounting
Pipe Size
NPT (in.)
Lead
Length
(ft./in.)
Ambient
Temp ºF
FIREYE™
UV-1
C7027A1080
b d
1/2 6/72 -40 to 212 Angle body.
UV-1A3
C7027A1080
b
1/2 3/36 -40 to 212 Straight body.
UV-1A6
C7027A1080
b
1/2 6/72 -40 to 212 Straight body.
UV-2
C7027A1080
b
3/8 3/36 -40 to 212 Straight body.
UV-6
C7027A1080
b d
1/2 6/72 -40 to 212 Angle body.
UV-7
C7027A1080
b
3/8 6/72 -40 to 212 Angle body.
45UV21010
C7027A1080
b c d
3/4 None -40 to 200 Angle body.
45UV21112
C7027A1080
b c d
3/4 None -40 to 200 Angle body.
45UV21113
C7027A1080
b c d
3/4 None -40 to 200 Angle body.
45UV31050
C7027A1080
b c d
3/4 None 212 max. Angle body.