Instruction Manual

Relialign
RDI Series
Residential Door Interlock
ISSUE 3
50079027
CLEARANCE BETWEEN HOIST WAY DOORS,
LANDING SILLS, AND CAR DOOR
The clearance between the hoistway doors or gates and
the hoistway edge of the landing sill shall not exceed 75
mm [3 in]. The distance between the hoistway face of the
landing door or gate and the car door or gate shall not
exceed 125 mm [5 in]. (See Figure 3).
FIGURE 3. CLEARANCE
IMPORTANT NOTICE
Strict compliance with installation instructions / mounting
template is essential for safety. It is the customer’s
responsibility to ensure they are followed. It is imperative
any wear on the actuator key or on the switch itself are
identified at an early stage and the necessary corrective
actions implemented (replacement), thus ensuring safety.
GENERAL DIRECTIONS
A. The actuator key for the switch MUST move freely
without jamming during operation
B. The alignment of the key to the switch MUST be
checked as per the mounting template
C. Visually ensure that no mechanical damage has
occurred to the switch body or key. If damage is
found the complete switch assembly MUST be
replaced
D. Test the switch for correct electrical operation while
installed and operated normally
FIGURE 4. WIRING SCHEMATIC
RDI PARALLEL CONNECTION, TERMINAL STRIP
CONNECTOR
FIGURE 5. WIRING SCHEMATIC
RDI PARALLEL CONNECTION, CAT 5 CONNECTOR
FIGURE 6. WIRING SCHEMATIC
RDI SERIES CONNECTION, TERMINAL STRIP
CONNECTOR
FIGURE 7. WIRING SCHEMATIC
RDI SERIES CONNECTION, CAT 5 CONNECTOR
4 Honeywell Sensing and Control