28 RP2/RP4 User Guide
4. Click the Quick Media button.
5. The printer feeds media while the sensor is calibrated. If the calibration is not
successful, repeat the procedure or use Manual Media Calibration.
Manual Media Calibration
Manual media calibration is used when the Quick Media Calibration has failed to
detect the start of each label. This procedure performs a complete recalibration of
the sensors and will optimize the printer to your media. In some instances, you may
need to perform a Quick Media Calibration after the manual media calibration to
further optimize the printers sensor.
Sensor calibration is needed to set either the black mark or the gap value of the
media sensor on the printer.
Gap Type Labels
1. Open the NETira CT Printer Configuration Utility Tool and click on Tools -
Query Printer Configuration (or press CTRL-q) to query the printer.
2. In the Printer Information column, click on Sensor Calibration.