Programmable Thermostat RTH2300/RTH221 Series Owner’s Manual Set Hold Run Read and save these instructions. Heat Off Cool Heat Off Cool For help please visit honeywellhome.
ATTENTION: MERCURY RECYCLING NOTICE Hg NO MERCURY N E PA S JE TE R LE MERCURE This product does not contain mercury. However, this product may replace a product that contains mercury. Mercury and products containing mercury should not be discarded in household trash. For more information on how and where to properly recycle a thermostat containing mercury in the United States, please refer to the Thermostat Recycling Corporation at www.thermostat-recycle.org.
Table of contents Installation Programming and operation Setting the clock......................................... 11 Adjusting program schedules.............. 12 Overriding schedules temporarily..... 13 Overriding schedules permanently.... 13 Compressor protection........................... 14 Change filter................................................. 14 Replace batteries........................................ 15 Installation........................................................
2 Remove Old Thermostat Remove old thermostat but leave wallplate with wires attached. If you have an older thermostat with a sealed mercury tube, turn to page 2 for proper disposal instructions. Do not remove wallplate yet Terminal designation C C 3 Label Wires with Tags MCR33823 Label the wires using the supplied wire labels as you disconnect them. Wire Labels C C MCR31537 Terminal designation 4 Separate Wallplate from New Thermostat Remove wallplate from the new thermostat and mount onto wall.
Mount Wallplate Mount the new wallplate using the included screws and anchors. W/ Aux Not Used M32714 Drill 3/16-in. holes for drywall Drill 3/32-in. holes for plaster 6 Connect Wires Simply match wire labels. If labels do not match letters on the thermostat, check “Alternate Wiring” on page 6 and connect to terminal as shown here (see notes, below). WIRE HOLE G INSERT WIRES AND TIGHTEN SCREWS SCREW R Y W W LABELED WIRES Remove metal jumper if you have both R and Rc wires.
Alternate Wiring 4 B O G Y 4 W NOT R USED Rc M32734 If wires will be connected to both R and Rc terminals, remove metal jumper. Do not use C or X. Wrap bare end of wire with electrical tape. If you have a heat pump without auxiliary/backup heat connect O or B, not both. If you do not have a heat pump, do not connect B. Wrap bare end of wire with electrical tape. Place a jumper (piece of wire) between Y and W if you are using a heat pump without auxiliary/backup heat.
8 Set fan operation switch Move the switch to the proper setting: RTHXXXX Gas or Oil: For gas or oil heating systems, leave the fan operation switch in this factory-set position (for systems that control the fan in a call for heat). GAS OR OIL ELECTRIC OR HEAT PUMP Electric or Heat Pump: Change the switch to this setting for heat pump or electric heat systems. (This setting is for systems that allow the thermostat to control the fan in a call for heat, if a fan wire is connected to the G terminal.
11 If your system type is... If your system type is: q Single Stage Heat and Cool q Heat Only or Cool Only Congratulations, you’re done! If your system type is: q Heat pump q Electric furnace q High efficiency furnace q Gas/oil steam q Hot water q Gravity system Continue with Advanced Installation to match your thermostat to your system type. This thermostat works on 24 volt or 750 mV systems. It will NOT work on multistage conventional systems.
NOTE: If you do not press any button for 60 seconds while you are in the setup menu, the thermostat automatically saves any changes made and exits the menu. Function Description Press the s or t button to Setting 5 select your heating system and optimize its operation 5 Gas or oil furnace: Use this setting if you have a standard gas or oil furnace that is less than 90% efficient. 6 Electric furnace: Use this setting if you have any type of electric heating system.
Thermostat controls Temperature adjustment Press the up or down buttons until you reach the desired temperature. Set: Press to set time/day/ schedule. Set Hold: Press to override programmed temperature control. Hold Run Run: Press to resume program schedule. Fan Fan Auto On Heat Off Cool Heat Off Cool Auto On M33612 System Switch is used to control your heating or cooling system. • Heat: Heating system control. • Off: All systems off. • Cool: Cooling system control.
Set the time and day 1. Press the SET button, then press s or t to set the clock time. 2. Press the SET button, then press s or t to select the day of the week. (RTH2300 only) 3. Press RUN to save & exit. Set Time 6:30 Set Hold am Run M33787 NOTE: If the clock flashes, the thermostat will follow your settings for the Monday “Wake” time period until you reset the time and day. Set Day Set Hold We Run M33788 Program Schedule You can program four time periods each day.
To adjust program schedules (RTH2300) 1. Press SET until Set Schedule is displayed. 2. Press s or t to set your weekday Wake time (Mo-Fr), then press SET. 3. Press s or t to set the temperature for this time period, then press SET. 4. Set time and temperature for the next time period (Leave). Repeat steps 2 and 3 for each weekday time period. 5. Press SET to set weekend time periods (Sa & Su), then press RUN to save & exit.
Program schedule override (temporary) Press s or t to immediately adjust the temperature. This will temporarily override the temperature setting for the current time period. 6:30 Set Hold Temporary am 70 Set Run “Temporary” will appear on the display and the current program period will flash. M33796 The new temperature will be maintained only until the next programmed time period begins (see page 11). 6:30 Set Hold am 75 Set Run To cancel the temporary setting at any time, press RUN.
Built-in compressor protection This feature helps prevent damage to the compressor in your air conditioning or heat pump system. 6:30 Damage can occur if the compressor is restarted too soon after shutdown. This feature forces the compressor to wait 5 minutes before restarting. We Wake am 75 Cool On During the wait time, the display will flash the message Cool On (or Heat On if you have a heat pump). When the safe wait time has elapsed, the message stops flashing and the compressor turns on.
Battery replacement Pull at bottom to remove thermostat from wallplate. Install two fresh AAA batteries when Lo Batt flashes on the screen. Lo Batt appears for 60 days before the batteries are depleted. UP Replace batteries once a year, or when you will be away for more than a month. W Most settings are stored in nonvolatile (permanent) memory. Only the clock and the day must be set after you replace the batteries. Set the System switch to Off before removing the batteries.
Troubleshooting If you have difficulty with your thermostat, please try the following suggestions. Most problems can be corrected quickly and easily. Display is blank • Make sure fresh AAA alkaline batteries are correctly installed. Heating or cooling system does not respond • Set system switch to Heat. Make sure the temperature is set higher than the Inside temperature. Set system switch to Cool. Make sure the temperature is set lower than the Inside temperature.
1-year limited warranty http://honeywellhome.
www.resideo.com Resideo Technologies Inc. 1985 Douglas Drive North, Golden Valley, MN 55422 http://honeywellhome.com/support 33-00102EF—05 M.S. Rev. 08-20 | Printed in United States © 2020 Resideo Technologies, Inc. All rights reserved. The Honeywell Home trademark is used under license from Honeywell International, Inc. This product is manufactured by Resideo Technologies, Inc. and its affiliates. Tous droits réservés.
Thermostat programmable RTH2300/RTH221 Série Manuel du propriétaire Set Hold Veuillez lire le mode d’emploi et le conserver en lieu sûr. Run Pour obtenir de l’aide veuillez visiter honeywellhome.
ATTENTION : AVIS RELATIF AU RECYCLAGE DU MERCURE Hg NO MERCURY N E PA S JE TE R LE MERCURE Ce produit ne contient aucun mercure. Cependant, ce produit peut remplacer un produit qui contient du mercure. Le mercure et les produits contenant du mercure ne doivent pas être jetés aux ordures ménagères.
Table des matières Installation Programmation et fonctionnement Réglage de l’horloge................................. 11 Réglage des programmes...................... 11 Dérogation temporaire de la programmation................................ 13 Dérogation permanente de la programmation................................ 13 Protection du compresseur.................. 14 Changer le filtre (RTH2300)................. 14 Remplacement des piles........................ 15 Installation.............................
2 Retirer l’ancien thermostat Retirer l’ancien thermostat, mais laisser en place la plaque murale et les fils sans les détacher. Si vous possédez un thermostat plus ancien à tube Laisser la plaque de mercure scellé, allez à la page 2 pour les de montage en instructions de mise au rebut correctes. place Désignation de la borne C C 3 Étiqueter les fils MCR33823 Étiqueter les fils à l’aide des étiquettes fournies à mesure que les fils sont débranchés.
5 Installer la plaque Installer la nouvelle plaque murale à l’aide des vis et des chevilles d’ancrage fournies. W/ Aux Not Used M32714 Percer des trous de 3/16 po si le mur est en placoplâtre Percer des trous de 3/32 po si le mur est en plâtre 6 Raccorder les fils Il suffit ensuite de faire correspondre les fils avec les étiquettes. Si les étiquettes ne correspondent pas aux lettres du thermostat, consulter “Autre option de câblage” au page 6 (voir les notes dessous).
Autre option de câblage 4 ou ou 4 ou ou ou ou Ne pas raccorder B O G Y W NOT R USED Rc MF32734 Si des fils seront raccordés aux bornes R et Rc, enlever le cavalier en métal. Ne pas se servir de C ou X. Enrouler du ruban isolant sur le bout dénudé du fil. Si une thermopompe est installée sans chauffage auxiliaire/de secours, connecter O ou B mais pas les deux. Si aucune thermopompe n’est présente, ne pas connecter B. Appliquer du ruban électrique sur l’extrémité nue du fil.
8 Réglages du ventilateur Placer le sélecteur à la position qui correspond au système : Gas or Oil : S’il s’agit d’un système de chauffage au gaz ou au mazout, laisser le sélecteur à la position réglée en usine (pour les systèmes qui commandent la mise en marche du ventilateur lors d’une demande de chaleur). Electric or Heat Pump : Déplacer le commutateur à cette position si le système est une thermopompe ou un appareil de chauffage électrique.
11 Si votre système est du type suivant...
REMARQUE : Si aucun bouton n’est touché pendant 60 secondes dans le menu de configuration, le thermostat enregistre automatiquement toute modification effectuée et quitte le menu. Fonction Description Appuyer sur les touches s ou t pour Réglage 5 sélectionner le système de chauffage et optimiser son fonctionnement 5 Système de chauffage au gaz ou au mazout : Utiliser ce réglage si le système de chauffage au gaz ou au mazout est un modèle standard avec une efficacité inférieure à 90 %.
Commandes de thermostat Set : Appuyer sur cette touche pour régler l’heure/le jour/l’horaire. Réglage de la température Hold : Appuyer sur cette touche pour déroger au programme. Appuyer sur les touches haut ou bas jusqu’à l’obtention de la température désirée. Set Hold Run Run : Appuyer sur cette touche pour revenir au programme.
Régler et l’heure et le jour 1. Appuyer sur le bouton SET, puis sur s ou t pour régler l’heure. 2. Appuyer sur le bouton SET, puis sur s ou t pour choisir le jour de la semaine. (RTH2300 seulement) 3. Appuyer sur RUN pour enregistrer les réglages et quitter. REMARQUE : Si l’horloge clignote, le thermostat respecte la consigne prévue pour la période de réveil (Wake) du lundi jusqu’à ce que le jour et l’heure soient réglés.
Réglage de l’horaire (RTH2300) 1. Appuyer sur SET jusqu’à ce que les mots «Set Schedule» (régler l’horaire) apparaissent à l’écran. 2. Appuyer sur s ou t pour régler Set Set l’heure du réveil des jours de Hold Mo Tu We Th Fr semaine (Lun-Ven), puis appuyer Run Wake ensuite sur SET. Set Schedule 3. Appuyer sur s ou t pour régler la température de consigne pour cette période, puis appuyer sur SET. 4. Régler la température et l’heure de la période suivante (Leave, ou départ).
Dérogation (temporaire) au programme Appuyer sur s ou t pour ajuster immédiatement la température. Cette fonction permet de déroger à la température de consigne de la période en cours. Set Hold 6:30 Temporary am 70 Set Run M33796 Le terme « Temporary » (Provisoire) s’affiche et la période courante clignote. Set La nouvelle température de consigne restera en vigueur jusqu’au début de la prochaine période seulement (voir page 11).
Protection intégrée du compresseur Cette fonction sert à éviter d’endommager le compresseur qui fait partie du système de refroidissement ou de la thermopompe. 6:30 We Le compresseur pourrait en effet être endommagé s’il redémarre trop rapidement après avoir été mis à l’arrêt. Cette fonction oblige le compresseur à attendre 5 minutes avant de redémarrer. am 75 Cool On Wake M32711 Pendant cette attente, les mots «Cool On» (ou«Heat On» si le système utilisé est une thermopompe) clignotent à l’écran.
Remplacement des piles Mettre deux piles AAA neuves lorsque Lo Batt (Piles faibles) clignote à l’écran. Lo Batt (Piles faibles) s’affiche pendant 60 jours avant que les piles ne soient complètement déchargées. Tirer le thermostat par le bas pour le détacher de la plaque murale. Remplacer les piles une fois par an ou avant de quitter la maison pour une période de plus d’un mois. UP W La plupart des réglages sont sauvegardés dans la mémoire non volatile (permanente).
Dépannage En cas de difficultés avec le thermostat, essayer les suggestions suivantes. La plupart des problèmes peuvent être réglés rapidement et facilement. Rien n’apparaît à l’écran • S’assurer qu’il y a bien des piles alcalines AAA neuves en place. Le système de chauffage ou de refroidissement ne répond pas • Régler le sélecteur du système à Heat. S’assurer que le point de consigne est plus élevé que la température ambiante. Régler le sélecteur du système à Cool.
Garantie limitée d’un an http://honeywellhome.
www.resideo.com Resideo Technologies Inc. 1985 Douglas Drive North, Golden Valley, MN 55422 http://honeywellhome.com/support 33-00102EF—05 M.S. Rev. 08-20 | Imprimé aux États-Unis © 2020 Resideo Technologies, Inc. All rights reserved. The Honeywell Home trademark is used under license from Honeywell International, Inc. This product is manufactured by Resideo Technologies, Inc. and its affiliates. Tous droits réservés.