Use and Care Manual

8
Troubleshooting
If you have difficulty with your thermostat, please try the following suggestions.
Most problems can be corrected quickly and easily.
Display is
blank
Check circuit breaker and reset if necessary.
Make sure power switch for heating & cooling system is on.
Make sure furnace door is closed securely.
Make sure fresh AA alkaline batteries are correctly installed
(see page 6).
Heating
or cooling
system does
not respond
Press Mode button to set system Heat (see page 2).
Make sure the desired temperature is set higher than the
inside temperature.
Press Mode button to set system Cool (see page 2).
Make sure the desired temperature is set lower than the
inside temperature.
Check circuit breaker and reset if necessary.
Make sure power switch for heating & cooling system is on.
Make sure furnace door is closed securely.
Wait 5 minutes for the system to respond.
Temperature
settings do
not change
If display says “unlock”; see page 5. If not, verify you are
in the correct mode (heat, cool, em heat or auto); see page
2.
If you are in the correct mode, but you cannot set the heat
from 40 °F to 90 °F (4.5 °C to 32 °C), or set the cool from
50 °F to 99 °F (10 °C to 37 °C), you may have range-stops
restricting your setting. Check with the installer to see if
they set range-stops.
“Cool On” or
“Heat On” is
flashing
Compressor protection feature is engaged. Wait 5 minutes
for the system to restart safely, without damage to the
compressor (see page 5).
Electrical Ratings
Terminal Voltage (50 Hz/60 Hz) Running Current
W Heating 20 Vac - 30 Vac 0.02 A - 1.0 A
W2 (Aux) Heating (TH4210U only) 20 Vac - 30 Vac 0.02 A - 1.0 A
E Emergency Heat (TH4210U only) 20 Vac - 30 Vac 0.02 A - 0.5 A
Y Compressor Stage 1 20 Vac - 30 Vac 0.02 A - 1.0 A
G Fan 20 Vac - 30 Vac 0.02 A - 0.5 A
O/B Changeover 20 Vac - 30 Vac 0.02 A - 0.5 A
L/A Input 20 Vac - 30 Vac 0.02 A - 0.5 A