S9200U Installation Guide

Table Of Contents
S9200U1000 UNIVERSAL HOT SURFACE IGNITION INTEGRATED FURNACE CONTROL
69-2075EF—05 4
PCBBF136 32339630-
001
12x12 Main
Connector
(H)
50031795-
001
4x2 Inducer
& H.S.I.
Connector (G)
S1-OFF
S2-OFF
S3 & S4:
60/90/120/180
SW1-SW2
Check control
safety timing
before setting
PCBBF140
1
Wiring harness G should be used if the control being
replaced has a 2-pin inducer/igniter connector
instead of a 4-pin inducer/igniter connector.
Goodman/Daikin/Amana: GMS92,GMS96 GCS92,GCS96 GMS8,
GDS8, AMSS92, AMSS96, ACSS92, ACSS96, AMS8, ADSS8, DM92SS,
DC92SS, DM80SS, DD80SS
PCBBF136 32339630-
001
12x12 Main
Connector
(H)
50031795-
001
4x2 Inducer
& H.S.I.
Connector (G)
S1-OFF
S2-OFF
S3 & S4:
60/90/120/180
SW1-SW2
Check control
safety timing
before setting
PCBBF140
United Technologies
1012933D E
Main
Connector
F
Inducer & HSI
Connector
SW1: ON
SW2: OFF
SW3: ON
SW4: OFF
SW1: OFF
SW2: ON
1012-933D
1012-83-
9336AHSC1
1012-83-9337A
Table 1. S9200U1000 Replaces These Integrated
Furnace Controls. (Continued)
SKU Harness
Field Settings
Recommendation
- DIP Switch S1
Safety Timing
Settings -
DIP Switch S2
Texas Instruments
41F-5 E
Main
Connector
F
Inducer & HSI
Connector
SW1: ON
SW2: OFF
SW3 & SW4:
60/90/120/180
SW1: OFF
SW2: ON
White Rodgers
50T35730
50T35-730
50T35743
50T35-743
ICM280 SW1-SW4:
Check control
Field Settings
before setting.
SW1-SW2:
Check control
Safety Timings
before setting.
White Rodgers
1
50A50-110 A
Inducer & HSI
Connector
SW1: ON
SW2: OFF
SW3 & SW4:
60/90/120/180
SW1: OFF
SW2: ON
50A50-111
50A50-112
50A50-113
50A50-130 SW1: OFF
SW2: OFF
50A50-131
50A50-142
50A50-143 SW1: ON
SW2: Check
Settings
SW3 & SW4:
60/90/120/180
SW1: OFF
SW2: ON
50A50-205 SW1: ON
SW2: OFF
SW3: ON
SW4: OFF
SW1: OFF
SW2: ON
50A50-206
50A50-207 G
Inducer & HSI
Connector
50A50-208 A
Inducer & HSI
Connector
SW1: ON
SW2: OFF
SW3 & SW4:
60/90/120/180
SW1: OFF
SW2: OFF
50A50-209 SW1: ON
SW2: OFF
SW3: ON
SW4: ON
SW1: OFF
SW2: ON
50A50-210 SW1: ON
SW2: OFF
SW3 & SW4:
60/90/120/180
SW1: OFF
SW2: OFF
50A50-215
50A50-216
50A50-229
50A50-230
50A50-240
50A50-241
50A50-245
50A50-285 G
Inducer & HSI
Connector
SW1: OFF
SW2: OFF
SW3: ON
SW4: OFF
Table 1. S9200U1000 Replaces These Integrated
Furnace Controls. (Continued)
SKU Harness
Field Settings
Recommendation
- DIP Switch S1
Safety Timing
Settings -
DIP Switch S2