S9200U Installation Guide
Table Of Contents
- Application
- Features
- Specifications
- Installation and Configuration Overview
- Cross Reference
- Installation
- Safety Timings, Field Settings, and Fixed Parameters
- Thermostat Type
- Twinning
- Checkout
- I. Check Normal Operation
- II. Check Safety Shutoff Operation
- Troubleshooting
- Application
- CARACTÉRISTIQUES
- SPÉCIFICATIONS
- APERÇU DE L'INSTALLATION ET DE LA CONFIGURATION
- CORRESPONDANCES
- Installation
- TEMPORISATIONS DE SÉCURITÉ, RÉGLAGES DE COMMUTATEUR SUR SITE ET DE PARAMÈTRES FIXES
- TYPE DE THERMOSTAT
- PAIRAGE
- VÉRIFICATION
- I. VÉRIFICATION DU FONCTIONNEMENT NORMAL
- II. VÉRIFICATION DE LA COUPURE DE SÉCURITÉ
- DÉPANNAGE
S9200U1000 UNIVERSAL HOT SURFACE IGNITION INTEGRATED FURNACE CONTROL
5 69-2075EF—05
1
Wiring harness G should be used if the control being
replaced has a 2-pin inducer/igniter connector
instead of a 4-pin inducer/igniter connector.
50A50-286 A
Inducer & HSI
Connector
SW1: ON
SW2: OFF
SW3 & SW4:
60/90/
120/180
SW1: OFF
SW2: ON
50A50-288 G
Inducer & HSI
Connector
SW1: ON
SW2: OFF
SW3: ON
SW4: OFF
50A50-295
50A50-296 SW1: ON
SW2: OFF
SW3 & SW4:
60/90/120/180
50A50-298 SW1: OFF
SW2: OFF
1
Wiring harness G should be used if the control being
replaced has a 2-pin inducer/igniter connector
instead of a 4-pin inducer/igniter connector.
50A50-407 A
Inducer & HSI
Connector
SW1: ON
SW2: OFF
SW3 & SW4:
60/90/120/180
SW1: OFF
SW2: OFF
50A50-408 SW1: OFF
SW2: ON
50A50-438 SW1: Check
Settings
SW2: ON
SW3 & SW4:
60/90/120/180
50A50-472 SW1: OFF
SW2: OFF
50A50-475 SW1: ON
SW2: OFF
SW3 & SW4:
60/90/120/180
50A55-120 SW1: OFF
SW2: OFF
SW3: ON
SW4: OFF
50A55-143 SW1: ON
SW2: 30/60
SW3 & SW4:
60/90/120/180
50A55-241 SW1: ON
SW2: OFF
SW3: ON
SW4: ON
SW1: OFF
SW2: ON
50A55-245 SW1: ON
SW2: OFF
SW3 & SW4:
60/90/120/180
SW1: OFF
SW2: OFF
50A55-250
50A55-285
50A55-286 SW1: OFF
SW2: ON
50A55-288 G
Inducer & HSI
Connector
SW1: OFF
SW2: OFF
50A55-288-05
50A55-843 -
universal
A
Inducer & HSI
Connector
SW1: Check
Settings
SW2: Check
Settings
SW3 & SW4:
60/90/120/180
Table 1. S9200U1000 Replaces These Integrated
Furnace Controls. (Continued)
SKU Harness
Field Settings
Recommendation
- DIP Switch S1
Safety Timing
Settings -
DIP Switch S2
50M56U-843
(Replace 80V
Ignitors with 120V
Q3200U)
32339630-
001
12x12 Main
Connector
(H)
50031795-
001
4x2 Inducer
& H.S.I.
Connector (G)
S1-Check Settings
S2-Check Settings
S3 & S4:
60/90/120/180
SW1: OFF
SW2: OFF
ICP
1010806 A
Inducer & HSI
Connector
SW1: ON
SW2: OFF
SW3 & SW4:
60/90/120/180
SW1: OFF
SW2: OFF
1380686 SW1: OFF
SW2: ON
1380698 SW1: OFF
SW2: OFF
1380699
1380-686 SW1: OFF
SW2: ON
1380-699
Lennox
X445901 A
Inducer & HSI
Connector
SW1: ON
SW2: OFF
SW3 & SW4:
60/90/120/180
SW1: OFF
SW2: OFF
1214201 SW1: ON
SW2: OFF
SW3: ON
SW4: OFF
SW1: OFF
SW2: OFF
Other Manufacturers
X13120666010 A
Inducer & HSI
Connector
SW1: ON
SW2: OFF
SW3 & SW4:
60/90/120/180
SW1: OFF
SW2: OFF
10334901 A
Inducer & HSI
Connector
SW1: ON
SW2: OFF
SW3 & SW4:
60/90/120/180
SW1: OFF
SW2: OFF
350486
8068142
8068561
8068563
99958174
99958175
Table 1. S9200U1000 Replaces These Integrated
Furnace Controls. (Continued)
SKU Harness
Field Settings
Recommendation
- DIP Switch S1
Safety Timing
Settings -
DIP Switch S2