9 69-2075EF—05
.
Fig. 4. Typical mounting orientation showing wiring connections and components of the
S9200U1000 Universal Integrated Furnace Control.
Table 6. Wiring Connections (Class 1, Line Voltage).
Terminal Type Connection (see Fig. 4 on page 9) Connects S9200U1000 to:
4-pin connector
(male terminals)
Igniter-Inducer Harness Connector See Table 4
Straight Spade
Quick-connect
COOL Circulator cool speed output
EAC Electronic Air Cleaner 120 Vac output
HEAT Circulator heat speed output
CONT Continuous circulation
XFMR Transformer 120 Vac output
L1 Line 120 Vac hot power supply
HUM Humidifier 120 Vac output
PARK Circulator Motor Park 120 Vac input
PARK Circulator Motor Park 120 Vac input
Straight Spade
Quick-connect
Neutrals Any neutral connector can be used for:
120 Vac Input neutral
Transformer neutral
Electronic air cleaner neutral
Circulator neutral
Humidifier neutral
Straight Spade
Quick-connect
Flame Flame Sense - Signal input (90 Vac, current limited)
E-COM
LOCKOUT
JUMPER
FLAME
STATUS
E-COM
FUSE
XFMR
24 VAC
COM FLAME
HEAT
EAC
COOL
NEUTRALS
PARKPARK HUM
D/1C/3R/2WGY
ONON
S1
S2
1 2 3 41 2
ON
CONT
MOUNTING HOLE (X2)BOARD CLIPS (X6)
PLASTIC MOUNTING TRAY
M24908A
L1
1 4