Datasheet

SIZE
DRAWING NAME
SHEET
A2
TITLE
SCALE
THIS DRAWING COVERS A PROPRIETARY ITEM
AND IS THE PROPERTY OF HONEYWELL.
THIS DRAWING IS NOT TO BE COPIED OR USED
WITHOUT THE PERMISSION OF HONEYWELL.
TOLERANCES UNLESS NOTED:
DRAWN
CHECK
Pro/ENGINEER
REV
TYPE
HONEYWELL
PART NUMBER
1
A
B
C
D
E
F
F
E
D
C
B
A
23
45
67
8
1
2
3
4
5
6
7
8
FO-55117-B
CAGE CODE
LINEARITY #0.4%
OF FULL SCALE
ANGLE
LINEARITY #0.4%
OF FULL SCALE
23.85 #0.1
5.9 #0.1
9.99 #0.05
(52.23 )
B
130.3
(R )95
AIRGAP
8
8.58 #2.5
6.7 #0.05
0.4 A B C
2X 6.7 #0.05
(22.5 )
4.45 #2.5
(79.85 )
54.35
95.26
190.53
(3)
(35.4 )
( )90 $
JLH 9JUN10
JLH 9JUN10
SMART POSITION SENSOR, 180 ARC
1 OF 1
1:1
REV
DOCUMENT
CHANGED BY CHECK
E 0076277 MBN 08APR11 DSK
SPS-A180D-HAMS
INTERPRET PER ASME Y14.5M-1994
OTHER HONEYWELL ENGINEERING
STANDARDS MAY APPLY
3D
DESIGN UNITS: MM
I - SPS-A180D-HAMS E
SENSOR OUTPUT PERFORMANCE
PARAMETER MIN TYP MAX UNITS
SENSITIVITY 21.33 22.22 23.11 mV/DEGREE
MEASUREMENT DISTANCE 0 180 DEGREES
% LINEARITY -0.4 0 0.4 % FS
REF POINT "B"
MEASUREMENT ANGLE (DEGREES)
OUTPUT VOLTAGE (VOLTS)
PIN 2
NOMINAL SIGNAL OUTPUT CURVE
(THROUGH REFERENCE POINTS "A" AND "B")
0
0.5
4.5
4.75
SENSOR OUTPUT PERFORMANCE CHART
180 $
0$
REF POINT "A"
1.0
2.0
3.0
4.0
DEFINITIONS:
1 - % LINEARITY SHALL BE THE QUOTIENT OF THE MEASURED OUTPUT DEVIATION FROM THE BEST FIT LINE AT
THE MEASURED TEMPERATURE TO THE FULL SCALE OUTPUT SPAN
2 - % LINEARITY = (MEASURE VOLTAGE @ T - INDEX VOLTAGE [DEFINED BY BEST FIT LINE @ T]) / (FULL SCALE OUTPUT SPAN) X 100
3 - FS = FULL SCALE = 4 V
NOTES:
1 - PIN 2 IDEAL OUTPUT @ REF POINT A [ANGLE =0 $]: 0.5V
IDEAL OUTPUT @ REF POINT B [ANGLE =180 $]: 4.5V
2 - PIN 4 IDEAL OUTPUT @ REF POINT C [ANGLE =0 $]: 4.5V
IDEAL OUTPUT @ REF POINT D [ANGLE =180 $]: 0.5V
3 - OPERATING CONDITIONS:
TEMP RANGE -40 $C TO 85 $C
SUPPLY VOLTAGE 6.0 TO 24.0 VDC
SUPPLY CURRENT 45mA MAX
4 - MOUNTING
MAGNET PIN LOCATING HOLE: 10.25 # 0.10
MOUNTING SCREWS: 1/4-20 OR M6
RECOMMENDED INSTALLATION TORQUE: 53.1 TO 70.8 IN-LBS (6 TO 8 N-M)
5 - CONNECTOR PINOUT:
PIN 1: SUPPLY VOLTAGE (+) PIN 2: OUTPUT
PIN 3: GROUND (-) PIN 4: INVERTED OUTPUT
ONLY OUTPUT PIN 2 OR PIN 4 CAN BE CONNECTED AT A TIME
6 - FERROUS MATERIAL WITHIN 100 MM (3.9") RADIUS OF MAGNET MAY IMPACT SENSOR PERFORMANCE
7 - DIAGNOSTIC - MAGNET OUT OF RANGE: PIN 2 > 4.55, PIN 4 < .45
8 - TOLERANCE APPLIES FOR FULL SENSE RANGE
9 - DEVICE USED TO READ ANALOG OUPUT MUST HAVE INPUT IMPEDANCE GREATER THAN 1 MEGAOHM
10 - OUTSIDE OF THE VALID MEASUERMENT RANGE THE OUTPUT VOLTAGE WILL BE INDETERMINATE
11 - DIRECT IMPACT TO THE CONNECTOR MAY COMPROMISE THE INTEGRITY OF THE SENSOR AND COMPROMISE
THE SEAL RATING. HONEYWELL ADVISES MEASURES BE ESTABLISHED TO PREVENT DIRECT IMPACT.
0.25
REF POINT "C"
PIN 4
NOMINAL SIGNAL OUTPUT CURVE
(THROUGH REFERENCE POINTS "C" AND "D")
REF POINT "D"
SEE DETAIL
A
(0 $)
(180 $)
CABLE DIRECTION FOR
RIGHT ANGLE CONNECTOR
M12 (4 POS) CONNECTOR
A-KEYED PER IEC 61076
DETAIL
A
SCALE 3:1
C
A

Summary of content (8 pages)