TH6000 Series Operation Manual

FocusPRO
6000
Series
Programmable
Digital
Thermostat
Product
Information
33-00303EFS-01
Product Manuals
Search online for Honeywell 691921EFS for the User’s Guide.
CAUTION
Equipment damage hazard
To prevent possible compressor damage, do not operate
cooling system when outdoor temperature is below 50°F
(10°C).
Function buttons
Press to select the function displayed just above each
button. (Functions change depending on the task.)
Temperature buttons
Press to set preferred temperature.
Battery holder
Thermostat controls
Digital display
Hold Button
Press to override programmed
temperature control
Reference card
Set Clock/Day/
Schedule
Auto
Wake Wed
Fan
In Recovery
System
Auxiliary
Heat On
Heat
Heat
Setting
Inside
AM
72
72
6
:
30
Replace Battery
MCR29458
Display screen
Low battery
warning
Press the FAN
button to select:
Auto:
Fan runs only
when heating or cooling
system is on.
On: Fan runs continuously.
Press the SYSTEM
button to select:
Heat:
Heating system
control.
Cool: Cooling system
control.
Off: All systems off.
Auto: Thermostat
automatically selects
heating or cooling
depending on the
indoor temperature.
Em Heat: Emergency
& Auxiliary Heat
control. Compressor
is locked out. (Select
models only.)
Function buttons
Press the button beneath each
function to view or change
settings (functions change
depending on the task)
System Status
Cool On: Cooling
system is on.
Heat On: Heating
system is on.
Temperature
setting
Current inside
temperature
Auxiliary heat (Only
for heat pumps with
auxiliary heat)
Press the SET
button to change:
Clock:
Current time.
Day: Current day.
Schedule: Current
thermostat program
schedule.
Program Schedule
You can program four time periods each day, with different settings for
weekdays and weekends. We recommend the pre-set settings (shown in
the table below), since they can reduce your heating/cooling expenses.
Wake - Set to the time you awaken
and the temperature you want during
the morning, until you leave for the
day.
Leave - Set to the time you leave
home and the temperature you
want while you are away (usually an
energy-saving level).
Return - Set to the time you return
home and the temperature you want
during the evening, until bedtime.
Sleep - Set to the time you go to bed
and the temperature you want overnight (usually an energy-saving level).
NOTE: Leave and Return periods can be canceled on weekends.
Heat Cool
Wake
(6:00 am)
70
°
75
°
Leave
(8:00 am)
62
°
83
°
Return
(6:00 pm)
70
°
75
°
Sleep
(10:00 pm)
62
°
78
°
Program schedule override (temporary)
To adjust program schedules
1. Press SET CLOCK/DAY/SCHEDULE, then
SET SCHEDULE.
2. Press s or t to set your weekday
Wake time (MonFri), then press
NEXT.
3. Press s or t to set the temperature
for this time period, then press NEXT.
4. Set time and temperature for the
next time period (Leave). Repeat
steps 2 and 3 for each weekday time
period.
5. Press NEXT to set weekend time
periods (SatSun), then press DONE
to save & exit.
Set Clock/Day/
Schedule
Auto
FanSystem
Cool
Done
Set Day Set Schedule
Mon Tue Wed Thu Fri
Done
CancelPeriod
Leave
Set Schedule
Next
Heat
Setting
AM
62
8
:
00
MCR29462
Run Schedule
Auto
FanSystem
Heat
Heat
Setting
Inside
AM
69
75
6
:
30
Temporary
MCR29463
Press s or t to immediately
adjust the temperature. This
will temporarily override the
temperature setting for the
current time period.
The new temperature will be
maintained only until the
next programmed time period
begins. For example, if you
want to turn up the heat early in the morning, it will automatically be
lowered later, when you leave for the day.
To cancel the temporary setting at any time, press RUN SCHEDULE.
NOTE: Make sure the thermostat is set to the system you want to control
(heat, cool or auto).
NOTE: Make sure the thermostat is set to the system you want to
program (Heat or Cool).
NOTE: You can press CANCEL PERIOD to eliminate unwanted time periods
(except Wake).

Summary of content (4 pages)