VisionPRO 8000 Spec Sheet 2017
Table Of Contents
- Application
- Features
- Contents
- Specifications
- System Installation
- Installation Options
- Guidelines for Installing RedLINK Devices
- Installing Equipment Interface Module (if used)
- Wiring 24 Vac Common
- Selecting Discharge and Return Air Temperature Sensor Mounting Locations
- Installing Discharge and Return Air Temperature Sensors
- Selecting Thermostat Location
- Installing Wallplate
- Installing VisionPRO® 8000 with RedLINK™
- Wiring the Thermostat
- Remove Coin Cell Battery Tab
- Mounting Thermostat on Wallplate
- Power Optional RedLINK™ Accessories
- Performing Initial Setup
- Installer Tests
- Operation
- Setting the Time/Date
- Setting the Fan
- Setting System Mode
- Adjusting Program Schedules
- Overriding Schedules: Residential Use
- Overriding Schedules: Commercial Use
- Viewing Equipment Status
- Setting Vacation Hold: Residential Use
- Setting Holiday/Event Schedules: Commercial Use
- Setting Custom Events: Commercial Use
- Setting Holiday Schedule: Commercial Use
- Setting Holiday Override: Commercial Use
- Initiating Occupancy Mode: Commercial Use
- Remote Setback: Commercial Use
- Adjusting Humidification Settings
- Adjusting Dehumidification Settings: Residential Use
- Adjusting Dehumidification Settings: Commercial Use
- Adjusting Ventilation Settings
- Ventilation Options
- Setting Preferences
- Cleaning the Thermostat Screen
- Adjusting Security Settings
- Viewing Dealer Information
- Advanced Features
- Installer Options
- Using the Temperature Display
- Using the Humidity Display
- Universal Outputs (U1, U2, U3)
- Universal Inputs (S1, S2, S3, S4)
- Data Logs
- Dry Contact Alerts
- Set Up the Dry Contact Alerts
- Staging Control
- Heat Pump and Backup Heat Operation
- Indoor Air Quality (IAQ) Control
- IAQ Reminders
- Customizable Reminders
- MicroSD card
- Commercial Features
- Overriding Schedules: Commercial Use
- Setting Holiday/Event Schedules: Commercial Use
- Setting Custom Events: Commercial Use
- Setting Holiday Schedule: Commercial Use
- Setting Holiday Override: Commercial Use
- Initiating Occupancy Mode: Commercial Use
- Ramp Rates (Commercial Use)
- Remote Setback (Commercial Use)
- Economizer and Time of Day (TOD) Operation
- Pre-Occupancy Purge
- Battery Replacement
- Optional Accessories
- Portable Comfort Control
- Remote Indoor Sensors
- Replacing a Thermostat
- Replacing an Equipment Interface Module
- Wiring
- Zoning
- Troubleshooting
- Regulatory Information
VISIONPRO
®
8000 WITH REDLINK™
121 68-0312—05
WIRING
See Table 9 for Equipment Interface Module terminal descriptions and Table 10 for thermostat terminal descriptions.
* Remove jumpers when separate transformers are used.
†
See “Wiring IAQ Equipment or a Heat/Cool Stage to the Universal Terminals” beginning on page 134.
‡
See “Dry Contact Alerts” beginning on page 74 for wiring Dry Contact Devices to display alerts.
Table 9. Equipment Interface Module Terminal Designation Descriptions.
Conventional System Heat Pump
Terminal Description Terminal Description
C Common wire from 24 VAC transformer. C Common wire from 24 VAC transformer.
R* Power wire from 24 VAC transformer. R Power wire from 24 VAC transformer.
RH* Heating power RH Heating power
RC* Cooling power RC Cooling power
W Heat Stage 1 O/B Changeover valve for heat pumps
W2 Heat Stage 2 AUX 1 Backup Heat Stage 1/Emergency Heat Stage 1
W3 Heat Stage 3 AUX 2 Backup Heat Stage 2/Emergency Heat Stage 2
Y Compressor Stage 1 Y Compressor Stage 1
Y2 Compressor Stage 2 Y2 Compressor Stage 2
G Fan Relay G Fan Relay
A Connect to Economizer Module or Lighting
Panel (TOD).
L/A Connect to Compressor Monitor, Zone Panel,
Economizer Module or Lighting Panel (TOD).
U1 / U1
†
U2 / U2
†
U3 / U3
†
Universal relay for humidification,
dehumidification, ventilation, or a stage of
heating/cooling. U terminals are dry contacts
that require power.
U1 / U1
†
U2 / U2
†
U3 / U3
†
Universal relay for humidification,
dehumidification, ventilation, or a stage of
heating/cooling. U terminals are dry contacts
that require power.
S1 / S1
‡
S2 / S2
‡
S3 / S3
‡
S4 / S4
‡
Universal input for a wired indoor sensor,
outdoor sensor, discharge sensor, return
sensor, dry contact device for alerts or dry
contact device for remote setback.
S1 / S1
‡
S2 / S2
‡
S3 / S3
‡
S4 / S4
‡
Universal input for a wired indoor sensor,
outdoor sensor, discharge sensor, return
sensor, dry contact device for alerts or dry
contact device for remote setback.
A
B
C
D
Connect to THM4000R1000 Wireless Adapter
for extended wireless range.
A
B
C
D
Connect to THM4000R1000 Wireless Adapter
for extended wireless range.