VisionPRO 8000 Spec Sheet 2017
Table Of Contents
- Application
- Features
- Contents
- Specifications
- System Installation
- Installation Options
- Guidelines for Installing RedLINK Devices
- Installing Equipment Interface Module (if used)
- Wiring 24 Vac Common
- Selecting Discharge and Return Air Temperature Sensor Mounting Locations
- Installing Discharge and Return Air Temperature Sensors
- Selecting Thermostat Location
- Installing Wallplate
- Installing VisionPRO® 8000 with RedLINK™
- Wiring the Thermostat
- Remove Coin Cell Battery Tab
- Mounting Thermostat on Wallplate
- Power Optional RedLINK™ Accessories
- Performing Initial Setup
- Installer Tests
- Operation
- Setting the Time/Date
- Setting the Fan
- Setting System Mode
- Adjusting Program Schedules
- Overriding Schedules: Residential Use
- Overriding Schedules: Commercial Use
- Viewing Equipment Status
- Setting Vacation Hold: Residential Use
- Setting Holiday/Event Schedules: Commercial Use
- Setting Custom Events: Commercial Use
- Setting Holiday Schedule: Commercial Use
- Setting Holiday Override: Commercial Use
- Initiating Occupancy Mode: Commercial Use
- Remote Setback: Commercial Use
- Adjusting Humidification Settings
- Adjusting Dehumidification Settings: Residential Use
- Adjusting Dehumidification Settings: Commercial Use
- Adjusting Ventilation Settings
- Ventilation Options
- Setting Preferences
- Cleaning the Thermostat Screen
- Adjusting Security Settings
- Viewing Dealer Information
- Advanced Features
- Installer Options
- Using the Temperature Display
- Using the Humidity Display
- Universal Outputs (U1, U2, U3)
- Universal Inputs (S1, S2, S3, S4)
- Data Logs
- Dry Contact Alerts
- Set Up the Dry Contact Alerts
- Staging Control
- Heat Pump and Backup Heat Operation
- Indoor Air Quality (IAQ) Control
- IAQ Reminders
- Customizable Reminders
- MicroSD card
- Commercial Features
- Overriding Schedules: Commercial Use
- Setting Holiday/Event Schedules: Commercial Use
- Setting Custom Events: Commercial Use
- Setting Holiday Schedule: Commercial Use
- Setting Holiday Override: Commercial Use
- Initiating Occupancy Mode: Commercial Use
- Ramp Rates (Commercial Use)
- Remote Setback (Commercial Use)
- Economizer and Time of Day (TOD) Operation
- Pre-Occupancy Purge
- Battery Replacement
- Optional Accessories
- Portable Comfort Control
- Remote Indoor Sensors
- Replacing a Thermostat
- Replacing an Equipment Interface Module
- Wiring
- Zoning
- Troubleshooting
- Regulatory Information
VISIONPRO
®
8000 WITH REDLINK™
131 68-0312—05
Fig. 325. Hot water radiant heat with backup forced air
heat. Zoned with forced air zone panel and hot water
panel.
Fig. 326. Hot water fan coil with forced air furnace
backup heat.
M31485
HOT WATER
RELAY PANEL
RH W
W
W2
W3
W
Y
G
R
C
HZ311, HZ322, OR HZ432 ZONE PANELS COULD BE USED TO
CONTROL A FORCED AIR FURNACE ZONED WITH DAMPERS.
AN AQ2000 SERIES HOT WATER ZONE PANEL OR OTHER
RELAY-BASED HOT WATER ZONE 3 PANEL COULD BE USED.
L
TO THERMOSTAT
THERMOSTAT/EIM
CONV
ZONE 1
ZONE 1
1
2
1
2
RELAY
3
1
W
W2
W3
W
Y
G
R
C
CONFIGURE THE THERMOSTAT TO ENERGIZE THE FAN
WITH A CALL FOR HEAT.
THE BOILER IS CONTROLLING THE CIRCULATOR PUMP
IN THIS DIAGRAM.
L
TO THERMOSTAT
THERMOSTAT/EIM
CONV
FURNACE
M31486
1
2
2
1
BOILER
T
T
RELAY
3
1