VisionPRO 8000 Spec Sheet 2017
Table Of Contents
- Application
- Features
- Contents
- Specifications
- System Installation
- Installation Options
- Guidelines for Installing RedLINK Devices
- Installing Equipment Interface Module (if used)
- Wiring 24 Vac Common
- Selecting Discharge and Return Air Temperature Sensor Mounting Locations
- Installing Discharge and Return Air Temperature Sensors
- Selecting Thermostat Location
- Installing Wallplate
- Installing VisionPRO® 8000 with RedLINK™
- Wiring the Thermostat
- Remove Coin Cell Battery Tab
- Mounting Thermostat on Wallplate
- Power Optional RedLINK™ Accessories
- Performing Initial Setup
- Installer Tests
- Operation
- Setting the Time/Date
- Setting the Fan
- Setting System Mode
- Adjusting Program Schedules
- Overriding Schedules: Residential Use
- Overriding Schedules: Commercial Use
- Viewing Equipment Status
- Setting Vacation Hold: Residential Use
- Setting Holiday/Event Schedules: Commercial Use
- Setting Custom Events: Commercial Use
- Setting Holiday Schedule: Commercial Use
- Setting Holiday Override: Commercial Use
- Initiating Occupancy Mode: Commercial Use
- Remote Setback: Commercial Use
- Adjusting Humidification Settings
- Adjusting Dehumidification Settings: Residential Use
- Adjusting Dehumidification Settings: Commercial Use
- Adjusting Ventilation Settings
- Ventilation Options
- Setting Preferences
- Cleaning the Thermostat Screen
- Adjusting Security Settings
- Viewing Dealer Information
- Advanced Features
- Installer Options
- Using the Temperature Display
- Using the Humidity Display
- Universal Outputs (U1, U2, U3)
- Universal Inputs (S1, S2, S3, S4)
- Data Logs
- Dry Contact Alerts
- Set Up the Dry Contact Alerts
- Staging Control
- Heat Pump and Backup Heat Operation
- Indoor Air Quality (IAQ) Control
- IAQ Reminders
- Customizable Reminders
- MicroSD card
- Commercial Features
- Overriding Schedules: Commercial Use
- Setting Holiday/Event Schedules: Commercial Use
- Setting Custom Events: Commercial Use
- Setting Holiday Schedule: Commercial Use
- Setting Holiday Override: Commercial Use
- Initiating Occupancy Mode: Commercial Use
- Ramp Rates (Commercial Use)
- Remote Setback (Commercial Use)
- Economizer and Time of Day (TOD) Operation
- Pre-Occupancy Purge
- Battery Replacement
- Optional Accessories
- Portable Comfort Control
- Remote Indoor Sensors
- Replacing a Thermostat
- Replacing an Equipment Interface Module
- Wiring
- Zoning
- Troubleshooting
- Regulatory Information
VISIONPRO
®
8000 WITH REDLINK™
68-0312—05 136
Economizer Module Wiring Diagrams
Fig. 339. Economizer control with economizer fault alert using TH8321R without EIM.
Configure the TH8321R to control economizer (see settings for ISU 222).For the thermostat to economizer wiring other
than the U1 and A-L/A, see the other economizer diagrams in this section.
Fig. 340. Economizer control with custom alert when using an EIM.
Wire a relay to one of the four sets of S terminals (as shown). Configure the Prestige to control economizer (see settings for
ISU 222) and use a custom alert (see ISU settings 600, 617– 620). For the EIM to economizer wiring other than the A-L/A
and S contacts, see the other economizer diagrams in this section.
TH8321R
SUB-BASE
Y2-I
Y2-O
Y1-I
Y1-O
C
R
OCC
E-GND
EXH1
FURNACE,
AIR-HANDLER,
OR RTU
C
R
C
RC
W7220 JADE
ECONOMIZER
AUX2-1
AUX1-0
A-L/A
R
U1
U1
M36870
EIM
Y2-I
Y2-O
Y1-I
Y1-O
C
R
OCC
E-GND
EXH1
C
R
RC
C
R
AUX2-1
AUX1-0
A-L/A
RH
RELAY
REQUIRED
S1 (OR S2 OR S3 OR S4)
S1 (OR S2 OR S3 OR S4)
M36871
W7220 JADE
ECONOMIZER
FURNACE,
AIR-HANDLER,
OR RTU