VisionPRO 8000 Spec Sheet 2017

Table Of Contents
VISIONPRO
®
8000 WITH REDLINK™
68-0312—05 94
2. Select the terminals wired to the Ventilator (or Fresh
Air Damper). See Fig. 227.
Fig. 227.
3. Select the Ventilation Control Method. See “Ventila-
tion Control Methods (ISU 1005)” on page 92 for
more information. See Fig. 228.
Fig. 228.
4. Select the Ventilation Fan Control. See “Ventilation
Fan Control (ISU 1006)” on page 93 for more infor-
mation. See Fig. 229.
NOTE: ISU 1006 is only displayed if the Ventilation
Type is ERV / HRV. The thermostat controls
the fan if the Ventilation Type is Fresh Air
Damper.
Fig. 229.
5. If ASHRAE was selected for ISU 1005, select the
Number of Bedrooms and Size of House. See Fig.
230.
Fig. 230.
6. If ASHRAE was selected for ISU 1005, enter the
Equipment Ventilation Rate (CFM). Be sure this set-
ting corresponds with the actual ventilation speed.
This setting determines how often the ventilation
equipment will operate to meet the ASHRAE 62.2
Standard. The thermostat will indicate the following
based on the Equipment Ventilation Rate, Square
Footage and Number of Bedrooms. See Fig. 231.
Provides an indication if it meets or does not meet
the ASHRAE 62.2 Standard.
Provides % run time that is needed to meet the
ASHRAE 62.2 Standard.
Fig. 231.
7. Select a Ventilation Priority (see Fig. 232):
c. Lockouts are Priority: The thermostat places a pri-
ority on lockouts versus the ASHRAE 62.2 ventila-
tion standard. The thermostat will not run
ventilation during the following lockout condi-
tions (if configured) unless you manually call for
ventilation:
Scroll to see:
Meets ASHRAE
62.2
Ventilation will run