VisionPRO 8000 Spec Sheet 2017

Table Of Contents
VISIONPRO
®
8000 WITH REDLINK™
15 68-0312—05
TrueSTEAM
1. Wire and power TrueSTEAM.
2. Connect the ABCD terminals between TrueSTEAM
and the THM4000 Wireless Adapter.
3. Adjust the DIP Switches on TrueSTEAM as follows
when using the Wireless Adapter:
•DIP3: UP
•DIP4: UP
•DIP5: DOWN
Fig. 27. Powering TrueSTEAM wireless adapter.
Entry/Exit Remote or Vent Boost Remote
1. Remove the cover.
2. Insert the CR2450 coin cell battery (included) into
the slot at the bottom of the remote. See polarity
marking on the remote.
Fig. 28. Installing Entry/Exit Remote or Vent Boost
Remote battery.
3. The LED will briefly flash green. If it flashes red, bat-
tery is not good.
PERFORMING INITIAL SETUP
NOTE: If the thermostat is wired directly to the equip-
ment, 24 VAC (C wire) is required to connect
RedLINK accessories. Turn on 24 VAC before per-
forming the initial setup.
Initial setup options define the type of system you are
installing:
Residential or commercial
Non-zoned or zoned
Used with or without an Equipment Interface Module
(THM5421)
Used with or without the TrueZONE Wireless Adapter
(THM4000)
1. Follow prompts on the screen to select the appropri-
ate options.
Fig. 29. Select application (residential or commercial).
NOTE: If you are connecting the thermostat to the True-
ZONE Wireless Adapter (THM4000), refer to the
TrueZONE instructions to link the thermostat and
RedLINK accessories.
Linking Thermostat to Equipment
Interface Module (if used)
1. In thermostat setup, when you are prompted to
answer TSTAT CONTROLS AN EQUIP. MODULE:
select yes, then press Next.
Fig. 30.
2. Press and quickly release the CONNECT button on
the EIM. Make sure the “Connected” light is flashing
green.
Fig. 31. EIM CONNECT button.
NOTE: If the “Connected” light does NOT flash
green, another system may be in the listen-
ing mode. Please exit the listening mode at
the other system and then try again.
Green Flashing: In Listening Mode - system
is ready to add RedLINK devices.
Green Steady: RedLINK devices are commu-
nicating.
Red: RedLINK device(s) are NOT communi-
cating. Check EIM and RedLINK devices.
THM4000R1000
TrueSTEAM
MCR31476
6
543
2
ON
OFF
1
MCR33269
APPLICATION
residential
CONNECT