VisionPRO 8000 Spec Sheet 2017
Table Of Contents
- Application
- Features
- Contents
- Specifications
- System Installation
- Installation Options
- Guidelines for Installing RedLINK Devices
- Installing Equipment Interface Module (if used)
- Wiring 24 Vac Common
- Selecting Discharge and Return Air Temperature Sensor Mounting Locations
- Installing Discharge and Return Air Temperature Sensors
- Selecting Thermostat Location
- Installing Wallplate
- Installing VisionPRO® 8000 with RedLINK™
- Wiring the Thermostat
- Remove Coin Cell Battery Tab
- Mounting Thermostat on Wallplate
- Power Optional RedLINK™ Accessories
- Performing Initial Setup
- Installer Tests
- Operation
- Setting the Time/Date
- Setting the Fan
- Setting System Mode
- Adjusting Program Schedules
- Overriding Schedules: Residential Use
- Overriding Schedules: Commercial Use
- Viewing Equipment Status
- Setting Vacation Hold: Residential Use
- Setting Holiday/Event Schedules: Commercial Use
- Setting Custom Events: Commercial Use
- Setting Holiday Schedule: Commercial Use
- Setting Holiday Override: Commercial Use
- Initiating Occupancy Mode: Commercial Use
- Remote Setback: Commercial Use
- Adjusting Humidification Settings
- Adjusting Dehumidification Settings: Residential Use
- Adjusting Dehumidification Settings: Commercial Use
- Adjusting Ventilation Settings
- Ventilation Options
- Setting Preferences
- Cleaning the Thermostat Screen
- Adjusting Security Settings
- Viewing Dealer Information
- Advanced Features
- Installer Options
- Using the Temperature Display
- Using the Humidity Display
- Universal Outputs (U1, U2, U3)
- Universal Inputs (S1, S2, S3, S4)
- Data Logs
- Dry Contact Alerts
- Set Up the Dry Contact Alerts
- Staging Control
- Heat Pump and Backup Heat Operation
- Indoor Air Quality (IAQ) Control
- IAQ Reminders
- Customizable Reminders
- MicroSD card
- Commercial Features
- Overriding Schedules: Commercial Use
- Setting Holiday/Event Schedules: Commercial Use
- Setting Custom Events: Commercial Use
- Setting Holiday Schedule: Commercial Use
- Setting Holiday Override: Commercial Use
- Initiating Occupancy Mode: Commercial Use
- Ramp Rates (Commercial Use)
- Remote Setback (Commercial Use)
- Economizer and Time of Day (TOD) Operation
- Pre-Occupancy Purge
- Battery Replacement
- Optional Accessories
- Portable Comfort Control
- Remote Indoor Sensors
- Replacing a Thermostat
- Replacing an Equipment Interface Module
- Wiring
- Zoning
- Troubleshooting
- Regulatory Information
VISIONPRO
®
8000 WITH REDLINK™
68-0312—05 66
Fig. 114.
4. Review the settings and touch Done to save them.
Touch Cancel to ignore the changes.
NOTE: The cool temperature can only be set higher than
the unoccupied program setting and the heat
temperature can only be set lower than the unoc-
cupied program setting.
Initiating Occupancy Mode:
Commercial Use
This feature keeps temperature at an energy saving level
until you touch Press HERE to Start Occupancy. When you
arrive, touch the message to maintain a comfortable
temperature while the room is occupied.
Fig. 115.
Touch the or buttons to set the temperature or the
Hold Until time. The temperature is maintained until the
time you set. Temperature returns to an energy-saving level
after the timer expires, or the “Occupied” period ends.
NOTE: This feature is available only when programmed by
the installer.
Remote Setback: Commercial Use
During Occupied program periods, an occupancy sensor
directs the thermostat to go to REMOTE SETBACK settings
when the room is empty. If someone is in the room, it uses
the Occupied program period settings. The thermostat
ignores the occupancy sensor during Unoccupied program
periods.
If the thermostat is set up to be non-programmable, the
sensor directs the thermostat to go to REMOTE SETBACK
settings when the room is empty. If someone is in the room,
then it follows the settings set by the user.
Depending on how your thermostat was installed, it may
delay for up to 30 minutes before switching to REMOTE
SETBACK settings. This delay allows the room to stay
comfortable if the room is unoccupied for only a short time.
Adjusting Humidification Settings
1. Touch MENU and select Humidification.
Fig. 116.
Fig. 117.
2. Select Auto.
Fig. 118.
3. Touch or to select humidity level.
4. Touch Done to save your settings. Touch Cancel to
ignore changes.
5. If frost or condensation appears on the windows,
press MENU, scroll down and select Window Protec-
tion.
MCR34123
Temperature
While Away
M34127
Press HERE to
Start Occupancy
MCR34100
MCR34128
Humidification
Window Protection
MCR34129
Humidification
Off Auto