User Manual

ADDENDUM • ADDENDA • ANEXO
33-00092EFS-01
Wi-Fi VisionPRO
®
8000
UPDATE TO INSTALLATION GUIDE 33-00065 AND USER GUIDE 33-00066EFS:
USING WIRED OR INTERNET LOCAL OUTDOOR WEATHER DATA
The purpose of this addendum is to update the Performing Installer Setup page 5 of 33-00065 and page 28 of
33-00066EFS to enable the use of local outdoor weather data via Wi-Fi Internet connection.
33-00065: Page 5—Performing Installer Setup
1.5 USE OUTDOOR TEMP
NOTE: Choose WIRED/INTERNET to use local outdoor weather data for
your application.
33-00066EFS: Page 28—Adjusting Humidification Settings
NOTE: Window (frost) Protection is available only if an outdoor air sensor is installed OR if using the outdoor temperature from
the Wi-Fi connection to get local outdoor weather data from the Internet.
Wiring Diagram
Conventional Systems
1H/1C System (1 transformer)
Rc Power
R [R+Rc joined by jumper]
W Heat relay
Y Compressor contactor
G Fan relay
C 24VAC common
S1 Optional outdoor/remote sensor
1H/1C System (2 transformers)
Rc Power (cooling transformer)
R Power (heating transformer)
W Heat relay
Y Compressor contactor
G Fan relay
C 24VAC common
S1 Optional outdoor/remote sensor
Heat Only System
Rc Power
R [R+Rc joined by jumper]
W Heat relay
C 24VAC common
S1 Optional outdoor/remote sensor
Heat Only System With Fan
Rc Power
R [R+Rc joined by jumper]
W Heat relay
G Fan relay
C 24VAC common
S1 Optional outdoor/remote sensor
Heat Only System (Series 20)
Rc [R+Rc joined by jumper]
R Series 20 valve terminal “R”
W Series 20 valve terminal “B”
Y Series 20 valve terminal “W”
C 24VAC common
S1 Optional outdoor/remote sensor
Cool Only System
Rc Power
R [R+Rc joined by jumper]
Y Compressor contactor
G Fan relay
C 24VAC common
S1 Optional outdoor/remote sensor
2H/2C System (1 transformer)
Y2 Cool relay 2
W2 Heat relay 2
Rc Power
R [R+Rc joined by jumper]
W Heat relay 1
Y Cool relay 1
G Fan relay
C 24VAC common
S1 Optional outdoor/remote sensor
2H/2C System (2 transformers)
Y2 Cool relay 2
W2 Heat relay 2
Rc Power (cooling transformer)
R Power (heating transformer)
W
Heat relay 1
Y Cool relay 1
G Fan relay
C 24VAC common
S1 Optional outdoor/remote sensor
Heat Pump Systems
1H/1C Heat Pump (no auxiliary heat)
Rc Power
R [R+Rc joined by jumper]
O/B Changeover valve
Y Compressor relay
G Fan relay
C 24VAC common
S1 Optional outdoor/remote sensor
2H/2C Heat Pump (no auxiliary heat)
Y2 Compressor 2 relay
Rc Power
R [R+Rc joined by jumper]
O/B Changeover valve
Y Compressor 1 relay
G Fan relay
C 24VAC common
S1 Optional outdoor/remote sensor
2H/1C Heat Pump (with auxiliary
heat)
L Equipment monitor
Aux/E Auxiliary/Emergency heat relay
(Heat 2)
Rc Power
R [R+Rc joined by jumper]
O/B Changeover valve
Y Compressor relay
G Fan relay
C 24VAC common
S1 Optional outdoor/remote sensor
3H/2C Heat Pump (with auxiliary
heat)
Y2 Compressor 2 relay
L Equipment monitor
Aux/E Auxiliary/Emergency heat relay
(Heat 2)
Rc Power
R [R+Rc joined by jumper]
O/B Changeover valve
Y Compressor 1 relay
G Fan relay
C 24VAC common
S1 Optional outdoor/remote sensor
USE OUTDOOR TEMP
wired / internet