Owner’s Guide TrueIAQ® Digital IAQ Control 69-2072-05 69-2072_C.
Table of contents User Information ® About TrueIAQ ............................... 1 Operation..................................... 2 Display screen reference............ 3 Adjusting IAQ settings Changing humidifier settings...... 4 Changing dehumidifier settings.... 6 Changing ventilation settings....... 6 Changing time of day.................. 7 Service timers.............................. 7 Installer Information Installation................................... 8 Wiring.................................
About TrueIAQ® The TrueIAQ® monitors and automatically adjusts operation of your whole-house humidifier, dehumidifier, ventilator, or bath fan. Maintaining proper indoor humidity minimizes the potential for unhealthy airborne pollutants to grow. Having too little humidity can leave you vulnerable to infections and uncomfortable dry skin. Too much humidity creates ideal breeding grounds for mold, mildew and dust mites. Humidified air also feels warmer in the winter, and dry air feels cooler in the summer.
Operation TrueIAQ® can be used to control the humidity levels in your home, and control fresh air intake in accordance to industry recommendations (ASHRAE 62.2). Comfort Settings: Feedback on your indoor IAQ conditions. 1 Outdoor Conditions : Actual outdoor temperature and humidity. Indoor Conditions: Actual indoor temperature and humidity. 68 40 76 55 In Programmable Clock: Displays time and allows IAQ equipment programming based on time.
Display screen reference Wet: Indoor humidity levels are above 60% RH. Dry: Indoor humidity levels are below 20% relative humidity (RH.) 68 40 76 55 In % Out De Humidify: If “Humidify” is displayed, the control is calling for more humidity. If “DeHumidify” is displayed, the control is calling for humidity removal. % 12 : 15 PM Window Frost: The control is protecting your home against too much humidity based on outdoor conditions.
Changing humidifier settings Note: These items will appear only if a humidifier is installed on your system. 1. Set humidifier by pressing UP/DOWN arrows. 35 Tables below are recommended initial humidity settings based on outdoor temperature. If window frost setting (see next page) is not being used, the humidity setting should be adjusted manually when outdoor conditions change. Outdoor Temp.
Changing humidifier settings 2. Press “More” to enter Window Frost Protection. Use the UP/DOWN arrows to set frost protection level. MORE HUMIDITY LESS HUMIDITY TIGHT HOME/TRIPLE-PANE WINDOWS LOOSE HOME/SINGLE-PANE WINDOWS 1 2 3 4 5 6 7 8 9 Window Frost 7 Humidify M24830 On the first cold day after TrueIAQ is installed, look for condensation on windows. If present, lower Frost Protection by one. Once set for your home, Frost Protection does not need to be changed again. 3.
Changing dehumidifier and ventilation settings Note: These items will appear only if a dehumidifier is installed. If both a humidifier and dehumidifier are installed, these settings will appear after pushing “More” from the humidifier operation style screen. % 1. Set dehumidifier by pressing the UP/DOWN arrows. RH% will change in increments of five. DeHumidify 2. Press “More” to enter operation style. Press the UP/DOWN arrows to Set set.
68 40 Changing time of day and service timers 76 55 In % Out % 12 : 00 Set 1. Press “More.” Adjust hour using the the UP/DOWN arrows. 2. Press “More.” Adjust minutes using the UP/DOWN arrows. 3. Press “Done” to save settings. 68 40 76 55 In % Out % M24934 12 : 00 Set 68 40 76 55 In % Out Service Timers % 12 : 15 PM Service timers appear when the humidifier, dehumidifier, ventilator, air filter, and/or UV bulbs need service.
Installation CAUTION: ELECTRICAL HAZARD. Can cause electrical shock or equipment damage. Disconnect power before beginning installation. 1. Turn system power off. 2. Choose a location. TrueIAQ® can be mounted to a wall or directly to the return duct. ELECTRON IC AIR CLEANER M24787 69-2072—05 69-2072_C.
Installation 3. Loosen the cover screw. 4. Separate the front housing from the base. M24814 5. For wall mounting, run wires through the back hole to the terminals. Wire size for all connectors: 2 x 18 AWG to 1 X 22 AWG. Install the mounting plate using two screws. M24818 A 6. For duct mounting, (A) snap out side wall clip and attach as shown. Run wires through the side wall hole, under the clip, to the terminals. (B) Snap in sensor cap. 7.
Wiring Pin R Pin description Pin capacity 24V supply. Must be common to G output. 24Vac±20% 1.5 amp max C 24V supply common. 24Vac±20% Sensor Communication and supply bus to remote 24Vdc 64mA max out Sensor sensors (sensor pins not polarized). Switch Override switch input. Active when R is 24Vac±20%, applied 10mA max in W W input to sense when the thermostat is 24Vac±20%, calling for heat. Active when R is applied. 10mA max in G G input to sense fan calls. Active when R is 24Vac±20%, applied.
Wiring Wiring TrueIAQ® with a non-powered humidifier. R C TrueIAQ 68 40 76 55 In % SENSOR + 24V – TRANSFORMER THERMOSTAT R SENSOR C SWITCH W W Y Out % 12:15 PM G G VENT HVAC HE225 BYPASS HUMIDIFIER VENT DEHUM DEHUM HUM HUM M27340 69-2072_C.
Wiring Wiring TrueIAQ® with a powered humidifier. HVAC R C W TrueIAQ Y G HUM HUM 68 40 76 55 In % Out % 12:15 PM 24V 24V 24V RECOMMENDED PRESSURE SWITCH 24V HUM HUM C GT R RT GF R NOTE: 69-2072—05 69-2072_C.indd 12 Rc W Y G EXT FACTORY INSTALLED JUMPER TrueSTEAM - INTERNAL THERMOSTAT IF PRESSURE SWITCH IS USED, ENSURE DIP 5 IS IN ON POSITION.
Wiring Wiring TrueIAQ® with a dehumidifier and ventilation damper. TH8110U 1 R Rc C W Y G TrueIAQ 68 40 76 55 In % Out 12:15 PM 1 69-2072_C.indd 13 % R C SENSOR SENSOR SWITCH W G VENT VENT DEHUM DEHUM HUM HUM OUTDOOR SENSOR (PROVIDED) R C W Y G HVAC EARD-6 DH90 DEHUMIDIFIER GRAY DAMPER CONTROL (NOT USED) RED +24VAC POWER YELLOW COMPRESSOR CONTROL COMM.
Wiring Wiring TrueIAQ® with a humidifier and HRV/ERV ventilator. TrueIAQ 68 40 76 55 In % Out 12:15 PM 1 2 69-2072—05 69-2072_C.indd 14 TH8110U R Rc C W Y G 1 % R C SENSOR SENSOR SWITCH W G VENT VENT DEHUM DEHUM HUM HUM R C W Y G OUTDOOR SENSOR (PROVIDED) HVAC ERV/HRV RED BLACK GREEN HE265 R C 2 24 VOLT/40VA TRANSFORMER L2 L1 IF A THERMOSTAT OTHER THAN A TH5110, TH5220, TH5320, TH6110, TH6220, TH6320, TH8110, TH8320 OR TH8321 IS USED, A RELAY MAY BE REQUIRED TO ISOLATE THE G WIRE.
Wiring Wiring TrueIAQ® with a nonpowered humidifier, ventilation damper, and an auxiliary exhaust fan. TH8110U 1 R Rc C W Y G TrueIAQ 68 40 76 55 R C SENSOR SENSOR SWITCH W G VENT VENT DEHUM DEHUM HUM HUM In % Out % 12:15 PM R C W HVAC Y G OUTDOOR SENSOR (PROVIDED) EARD-6 HE265 2 EXHAUST FAN BLACK L1 120 VOLT POWER L2 WHITE R W G C Y 3 YELLOW R8239 FAN CENTER RELAY BLACK 69-2072_C.
Mounting the outdoor sensor 1. Do not mount on the south side of the house or in direct exposure to sunlight. 2. Keep at least 4 feet away from exhaust vents. 3. If in an air intake, place 1 foot closer to outside wall. 4. Place at least 6 inches higher than possible snow buildup. 5. Do not route sensor wire near high voltage wires. Note: The sensor can be extended using 18-gauge wire. M24821 69-2072—05 69-2072_C.
Advanced HVAC installer setup instructions 1. Press and hold the UP/ DOWN arrows for 3 seconds. 2. Press “More” to advance to the next setup option. See table on next page. M24823 3. Use the UP/DOWN arrows to select options. See table on next page. M24824 4. Press “Done” at any time to save and return to the home screen. M24825 69-2072_C.
Advanced programming To be used by qualified HVAC technician. Setup functions 10 15 Temperature Display Frost Protection 20 25 Humidity High Limit Humidifier Operation 30 35 50 55 60 Programmed Humidity Program Start Time (appears only if ISU30=1) Program End Time (appears only if ISU30=1) DEHUM Terminal Equipment Type High Dehum Limit Low Dehum Limit Dehumidifier Operation 65 Humidity Display Offset 80 Hum Service Timer 40 45 69-2072—05 69-2072_C.
Advanced programming Setup functions 85 90 95 100 105 110 115 120 125 130 135 140 145 Settings & Options (factory default in bold) 0,1,3,6,12 (months intermittent) 0,1,3,6,12 (months intermittent) 0,1,3,6,12 (months continuous) 0,1,3,6,12 (months continuous) 0=Clean ventilation filter 1=Change ventilation filter UV Bulb Service Reminder 0,6,12,24 (months continuous) Vent Options 0=No vent installed 1=Ventilation using VENT contacts 2=Ventilation using VENT contacts for high speed and DEHUM contacts for lo
Advanced programming Setup functions 150 155 160 ASHRAE: CFM Setting Maximum Vent Vent Shut-offs 165 Dehumidification Via Fresh Air Ventilator 69-2072—05 69-2072_C.indd 20 Settings & Options (factory default in bold) 3=30 CFM; 4=40 CFM, up to 20=200 CFM 00; 30%–95%. (00 setting runs to ASHRAE 100%) 0=Auto vent regardless of outdoor conditions 1=Off at 75°F dew point or 99°F air temp 2=Low speed at 65°F dew point or 85°F air temp.
Environmental standards/life expectancy TrueIAQ® Control and Outdoor Sensor • Operating/Storage temp: -40°F to 120°F (-40°C to 50°C) • Condensation Protection: 0-100% • Operating RH%: 0% to 99% noncondensing (TrueIAQ). Outdoor sensor protected from condensation. • Temp reading range: -40°C to 50°C (-40°F to 122°F) • Temp accuracy within range: 0.4°C (0.
5-year limited warranty Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of five (5) years from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunctions, Honeywell shall repair or replace it (at Honeywell’s option).