Power up and bind a Radiator Controller
(HR80)
If you want to control the zone temperature with your Central
Controller (the Central Controller needs to be located in that
zone) press YES, otherwise press NO and bind the sensor.
On the HR80, you need to bind the
sensor and actuator separately
1
Power up the Radiator Controller (see HR80 instructions)
To bind the sensor
2
On the Central Controller press the green bind button
3
Turn release clips on each side of the Radiator
Controller to remove the bottom plate
4
On the underside of the Radiator Controller
press the recessed bind button
5
The Radiator Controller screen should briefly show
a flashing RF icon then SYNC when successful.
The Central Controller will also show if binding
was successful (if not go back and re-bind)
If you are NOT following
GUIDED CONFIGURATION
follow these steps on your
Central Controller display
first:
1. On the Central Controller
press and hold “Settings”
for 3 seconds
2. Press the green tick
3. Press ADD ZONE
4. Press the zone you want
to add the controller to
5. Rename the zone if
required and/or press the
green tick
6. Press RADIATOR VALVE
Central
Controller
4
SIDE VIEW BOTTOM VIEW
Radiator Controller (HR80)
P22 Step 3: Power up and bind devices