Manual

T10 PRO SMART THERMOSTAT WITH REDLINK
33-00462—01 18
2070 Cool Stages /
Compressor
stages
0, 1, 2 1 0 setting not available if the system type
(ISU 2000) is set to Heat Pump
2071 Heat stages /
Backup heat
stages
0, 1, 2 1 Maximum of 2 Heat Stages for conventional
systems.
Maximum of 1 Backup Heat Stages for heat
pump applications. Note: this is not
counting the compressor heat stages on
heat pump systems.
2110 Fan Operation
in Heat
Equipment controls
fan
Thermostat controls
fan
Thermostat
controls fan
This ISU is only displayed if ISU 2010 is set
for Electric Forced Air or Hot Water Fan Coil.
The thermostat automatically energizes the
fan in heat when running a heat pump.
The thermostat automatically allows the
system to run the fan in heat when set for
gas or oil forced air systems. For radiant
systems (excluding hot water fan coil) the
thermostat does not energize fan in heat.
2175 Aux/E terminal
control
Drive aux and E
together
Aux and E
Independent
Drive aux and E
together
Only displayed if the system type (ISU 2000)
is set to Heat Pump) and Backup heat stages
(ISU 2071) is set to 1. Change to Aux and E
Independent only when you have separate
wires to Aux and E terminals on UWP and
want the AUX wire energized with heat pump
as backup heat and E energized separate of
heat pump when switched to em heat mode.
2180 Backup Heat
Type
Electric Forced Air
Standard Efficiency
Gas Forced Air
High Efficiency Gas
Forced Air
Electric Forced
Air
Only displayed if the system type (ISU 2000)
is set to Heat Pump) and Backup heat stages
(ISU 2071) is set to 1.
2185 Emergency
Heat Type
Electric Forced Air
Standard Efficiency
Gas Forced Air
High Efficiency Gas
Forced Air
Electric Forced
Air
Only displayed if the Aux/E terminal control
(ISU 2175) is set to “Aux and E Independent”.
2190 External Fossil
Fuel Kit
Thermostat controls
Backup Heat
External Fossil Fuel
kit controls backup
heat
Thermostat
controls
Backup Heat
Not displayed if equipment type (ISU 2000)
is set to cool only or cool stages (ISU 2070)
is set to 0.
This ISU is only displayed when ISU 2000
System Type is Heat Pump and ISU 2180
Backup Heat Type is Standard Efficiency
Gas Forced Air or High Efficiency Gas Forced
Air.
3000 Changeover Manual
Automatic
Automatic Not displayed if equipment type (ISU 2000)
is set to cool only or cool stages (ISU 2070)
is set to 0.
3015 Auto
Changeover
differential
0 °F-3 °F
(0.0 °C-2.5 °C)
0 Differential is the minimum number of
degrees rise or fall required during off cycle
to switch from the last active mode (heat or
cool) to the opposite mode when the
thermostat is in auto-changeover.
Differential is NOT deadband. See Auto
Changeover operation on page 37.
Table 5. Installer Setup (ISU)
ISU #
Installer Setup
Name Settings Default Notes