T10 PRO SMART THERMOSTAT WITH REDLINK
33-00462—01 24
8050 Humidification
Window
Protection
Off
On
Off Requires either wired outdoor sensor or
Internet weather (thermostat connected to
Wi-Fi and registered to the app).
Off: The thermostat controls the humidity
level to the user's desired humidity setting.
Frost or condensation may appear on
windows.
On: The thermostat prevents frost or
condensation on windows by not allowing
the humidity to go above the “Window Limit”
when it is controlling the humidifier. The
“Window Limit” is based on the current
outdoor temperature and the user's window
protection setting. The “Window Limit” is
displayed on the user's humidification
screen. See “Window Protection” on page 34.
8060 System modes
allowing
Humidification
Check box on screen
for each:
Heat
Off
Heat Click boxes on screen to select which system
modes allow humidification. If a box is NOT
checked, the thermostat will NOT allow
humidification to operate in that mode.
Heat: Includes Heat, Emergency Heat and
Auto. If the system is in Auto mode, the
thermostat will allow humidification if the
last call was for heat.
Off: The thermostat will allow humidification
when the system setting is Off.
See “Set up Humidification” on page 34.
8070 Humidification
Control
Humidify Only when
Heat is On
Humidify Only when
Fan is On
Humidify on
Demand:
Thermostat
Controls Fan
Humidify on
Demand: Humidifier
Controls Fan
Defaults to
Humidify Only
when Heat is
On when ISU
8000
Humidifier Type
is Bypass or Fan
Powered.
Defaults to
Humidify on
Demand:
Thermostat
Controls Fan
when ISU 8000
Humidifier Type
is Steam
Humidify Only when Heat is On: The
thermostat turns on the humidifier only if
the heat is currently running.
Humidify Only when Fan is On: The
thermostat turns on the humidifier only if
the fan is currently running.
Humidify on Demand - Thermostat Controls
Fan: The thermostat turns on the humidifier
and the fan when humidification is needed.
Humidify on Demand - Humidifier Controls
Fan: The thermostat turns on the humidifier
when humidification is needed and the
humidifier controls the fan.
8100 Humidifier Pad
Replacement
Reminder
Off
60 Run Time Days
90 Run Time Days
6 Calendar Months
12 Calendar Months
Off This ISU is only displayed if ISU 8000
Humidifier Type is Bypass or Fan Powered or
none. Run Time Days are not shown if ISU
8000 Humidifier Type is set to None
8100 Clean Tank/
Water Filter
Off
60 Run Time Days
90 Run Time Days
6 Calendar Months
12 Calendar Months
Off This ISU is only displayed if ISU 8000
Humidifier Type is Steam.
9000 What Type of
Dehumidifier
Equipment Do
you Have?
None
A/C with Low Speed
Fan
A/C with High
Speed Fan
Whole House
Dehumidifier
None See “Dehumidification” on page 34.
Whole House Dehumidification and A/C
with Low speed Fan only available if not
configured to control a Humidifier or
Ventilator. A/C with low Speed Fan requires
equipment that has a terminal
to lower fan speed.
Table 5. Installer Setup (ISU)
ISU #
Installer Setup
Name Settings Default Notes