T10 Pro Installation Manual

13
Screen is blank
Check circuit breaker and reset if necessary.
Make sure power switch at heating and cooling system is
on.
Make sure furnace door is closed securely.
Screen is difficult to
read
Check setting in MENU/ Preferences / Inactive backlight
brightness or Inactive sleep backlight brightness
Heating or cooling
system does not
respond
Touch MENU to go to system mode. Set to heat. Make sure
the heat setpoint is above the room temperature.
Touch MENU to go to system mode. Set to cool. Make sure
the cool setpoint is below the room temperature.
Check circuit breaker and reset if necessary.
Make sure power switch at heating & cooling system is on.
Make sure furnace door is closed securely.
Temperature
settings do not
change
Make sure heating and cooling temperatures are set to
acceptable ranges:
Heat: 40 °F to 90 °F (4.5 °C to 32.0 °C)
Cool: 50 °F to 99 °F (10.0 °C to 37.0 °C)
“Cool On” or “Heat
On” is flashing
Compressor protection feature is engaged. Wait 5 minutes
for the system to restart safely, without damage to the
compressor.
Aux heat runs in
cooling
For heat pump systems, verify there is not a wire attached
to W on UWP systems. See “Heat pumps systems" on page
7.
Cool runs with a call
for heat
For heat pump systems, verify there is not a wire attached
to W on UWP systems. See “Heat pumps systems" on page
7.
Heat runs with cooling
Verify there is not a wire attached to W for heat pump
systems. See "Wiring" on pages 67.
Sensor will not
connect
Press and hold Connect on the wireless sensor for 15
seconds. The LED will turn Amber. Return to the thermostat
menu and press Menu > Devices and Sensors. Follow the
on-screen instructions to add the sensor.
Troubleshooting