User Manual
19
TROUBLESHOOTING GUIDE (CONTINUED)
EN
PROBLEM POSSIBLE CAUSE SOLUTION
Unit runs but 
the humidity 
level does
not decrease
Insufficient time for the 
dehumidifier to remove 
moisture.
After initial installation, allow 24 hours to maintain 
desired dryness.
Dehumidifier 
runs constantly/ 
does not stop
Area to be dehumidified 
is too large.
The capacity of your dehumidifier may not be 
adequate for the room it is used in. It is recommended 
to add an extra dehumidifier for large areas.
A door or window is open,
letting in new moisture.
Make sure all windows or doors to the
outside are closed and tightly sealed.
Water Tank
Full is 
illuminated 
and the unit is 
beeping
The water tank is full. Empty the water tank.
The water tank is not in 
the correct position.
Position the water tank correctly into the unit. Unit
will not operate until the water tank is secure in place.
The unit is 
blowing cold air 
out of the top 
vent
The purpose of the top 
air vent is to distribute air 
into the room. 
The temperature of the air from the vent depends 
on the room environment and other factors. It can 
fluctuate and this is normal. No action required.
Frost appears 
on the coils
Dehumidifier has been
recently turned on in low
room temperatures 
(usually below 41°F 
(5°C)).
This is normal. Frost will disappear in an hour
or so after the dehumidifier is switched OFF.
Connected 
the continuous 
drain but 
the water 
condensation is 
not draining out 
the tube
Some floors may have 
an uneven surface 
which may affect the 
continuous drainage 
function
Raise the front of the Dehumidifier ½ to 1 inch 
(1.27 cm to 2.54 cm) from the floor. The water 
condensation will drain out the back hose and not 
into the bucket.