Installation Information

UC100A ULTRAVIOLET AIR TREATMENT SYSTEM REPLACEMENT LAMP
69-1382-4 G.H. Rev. 2-03 www.honeywell.com/yourhome
Automation and Control Solutions
Honeywell International Inc. Honeywell Limited-Honeywell Limitée
1985 Douglas Drive North 35 Dynamic Drive
Golden Valley, MN 55422 Scarborough, Ontario
M1V 4Z9
Printed in U.S.A. on recycled
paper containing at least 10%
post-consumer paper fibers.
This device contains mercury in the sealed ultraviolet
lamp(s). Do not place your used lamp (s) in the trash.
Dispose of properly.
Broken Lamp Cleanup.
Do not use a household vacuum.
Sweep debris (phosphor/glass) into a plastic bag and
dispose of properly.
Contact your local waste management authority for
instructions regarding recycling and the proper
disposal of old lamp(s).
Annual replacement of your lamps is required. To replace your
lamps:
1. Select and obtain the correct replacement lamp for your
unit. See Table 1.
2. Disconnect the power to your HVAC system.
3. Unplug your Ultraviolet Air Treatment System cord from
the electrical outlet and allow the lamps to cool for at
least 15 minutes.
4. Rotate the lamp knob counterclockwise and gently pull
the lamp knob to remove the lamp(s).
5. Insert the lamp into the base unit with the lamp light indi-
cator at the eleven o’clock position (left of the raised
button on the unit cover). Do not touch the lamp surface
with your hands.
6. Continue lightly pushing in on the lamp while rotating it
slowly counterclockwise. This should cause the lamp to
drop into the bottom of the lamp well.
7. Rotate the lamp clockwise until it snaps into place with
the lamp light indicator aligned with the raised button on
the unit cover.
WARNING
UV Light Hazard.
Harmful to bare skin and eyes.
Can cause temporary or permanent loss of vision.
Never look at the lamps while illuminated.
Only view illumination by way of the light indicator
located on the lamp knob.
To prevent exposure to ultraviolet light, disconnect
power to the ultraviolet air treatment system before
servicing any part of the heating/air conditioning
system.
8. Plug your UV100A1000, UV100A1018, UV100A1026 or
UV100A1059 Ultraviolet Air Treatment System cord into
the nearby 120 Vac electrical outlet. Plug your
UV100A2008 into a 240 Vac electrical outlet.
9. Verify that your ultraviolet lamp(s) are operating only by
viewing through the lamp light indicator on the lamp
knob. Never look directly at your lamp(s) while
illuminated.
10. Reconnect the power to your HVAC system.
Table 1. Replacing Your Lamp(s).
MERCURY NOTICE
Unit Description Replacement Lamps Wattage
UV100A1000 Single Lamp Return Air Unit UC100A1005 18W
UV100A1018 Two Lamp Return Air Unit UC100A1013 (twin pack) (two lamps required) 36W
UV100A1026 Coil Irradiation Unit UC100A1021 25W
UV100A1059 Coil Irradiation Unit UC100A1054 36W
UV100A2008 240 Vac Coil Irradiation Unit UC100A1054 36W